Physician scatter dose in interventional CT fluoroscopy
Open Access
- 14 April 2024
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (6)
Abstract
Purpose: To quantify operator dose in interventional CT fluoroscopy (CTF) procedures and compare to catheterization laboratory and interventional radiology procedures.Methods: Fifteen studies quantifying operator scatter dose for c‐arm fluoroscopy and CTF were reviewed from a literature survey. The dose provided in each study was normalized to skin entrance air kerma and air kerma rate including backscatter. The average air kerma rate and exposure duration were calculated and compared between c‐arm fluoroscopy and CTF. To enable operator scatter dose calculations in CTF procedures, a model was created which scaled the dose from a reference condition.Results: Our literature survey indicated that for CTF relative to c‐arm fluoroscopy: (1) the mean air kerma rate is 3.5 times higher, while (2) the mean exposure duration is 31.6 times lower. On average, a physician would have to perform 9.1 times (i.e., 31.6/3.5) more CTF procedures relative to c‐arm fluoroscopy procedure to receive equal operator scatter doses. Our own experimental measurements provided scaling factors allowing physician scatter dose to be obtained at any rotation time, tube current, beam collimation, or beam energy.Conclusion: Our results shed light onto a currently mis‐understood issue in radiology. Namely, that physicians receive more dose from CT relative to c‐arm fluoroscopy motivating them to retreat from the room during interventional exposures. Our literature review and experimental measurements indicate the opposite it true; interventional CT produces on average nine times less physician dose relative to c‐arm procedures. Our method allows for prospective/retrospective determination of an individual's dose.Keywords
This publication has 26 references indexed in Scilit:
- A Prototype Software System for Intra-procedural Staff Dose Monitoring and Virtual Reality Training for Fluoroscopically Guided Interventional ProceduresJournal of Digital Imaging, 2023
- CT Fluoroscopy for Image-Guided Procedures: Physician Radiation Dose During Full-Rotation and Partial-Angle CT ScanningJournal of Vascular and Interventional Radiology, 2021
- Eye lens dosimetry in interventional cardiology: results of staff dose measurements and link to patient dose levelsRadiation Protection Dosimetry, 2012
- Fluoroscopically guided percutaneous vertebroplasty: Assessment of radiation doses and implementation of procedural routines to reduce operator exposureActa Radiologica, 2009
- Occupational Radiation Exposure from Fluoroscopically Guided Percutaneous Transhepatic Biliary ProceduresJournal of Vascular and Interventional Radiology, 2006
- Randomized comparison of operator radiation exposure during coronary angiography and intervention by radial or femoral approachCatheterization and Cardiovascular Interventions, 2005
- Radiation Exposure to Operators during VertebroplastyJournal of Vascular and Interventional Radiology, 2005
- An accurate method for computer‐generating tungsten anode x‐ray spectra from 30 to 140 kVMedical Physics, 1997
- Introduction to Radiological Physics and Radiation Dosimetry1986