Imageless computer navigation for placement of the femoral component in resurfacing arthroplasty of the hip

Authors:
  • EDE. T. Davis
    E. T. Davis
  • ESE. H. Schemitsch
    E. H. Schemitsch
  • MCM. Chiu
    M. Chiu
  • PGP. Gamble
    P. Gamble
  • NTN. Tumia
    N. Tumia
  • RBR. A. Boyle
    R. A. Boyle

Abstract
We have investigated the accuracy of placement of the femoral component using imageless navigation in 100 consecutive Birmingham Hip Resurfacings. Pre-operative templating determined the native neck-shaft angle and planned stem-shaft angle of the implant. The latter were verified post-operatively using digital anteroposterior unilateral radiographs of the hip.The mean neck-shaft angle determined before operation was 132.7° (118° to 160°). The mean planned stem-shaft angle was a relative valgus alignment of 9.7° (sd 2.6). The stem-shaft angle after operation differed from that planned by a mean of 2.8° (sd 2.0) and in 86% of cases the final angle measured within ± 5° of that planned. We had no instances of notching of the neck or varus alignment of the implant in our series. A learning curve was observed in the time taken for navigation, but not for accurate placement of the implant.Navigation in hip resurfacing may afford the surgeon a reliable and accurate method of placement of the femoral component.

This publication has 35 references indexed in Scilit: