A Wireless Multi-Channel Peripheral Nerve Signal Acquisition System-on-Chip
Authors:
- Kian Ann NgKNKian Ann Ng
- Chao YuanCYChao Yuan
- Astrid RuslyARAstrid Rusly
- Anh-Tuan DoADAnh-Tuan Do
- Bin ZhaoBZBin Zhao
- Shih-Chiang LiuSLShih-Chiang Liu
- Wendy Yen Xian PehWPWendy Yen Xian Peh
- Xin Yuan ThowXTXin Yuan Thow
- Kai VogesKVKai Voges
- Sanghoon LeeSLSanghoon Lee
- Gil Gerald Lasam GammadGGGil Gerald Lasam Gammad
- Khay-Wai LeongKLKhay-Wai Leong
- 7 May 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 54 (8) , 2266-2280
Abstract
The adoption of chronic implantable peripheral nerve-based prosthetic devices is currently hampered by the lack of a highly integrated neural signal acquisition system-on-chip (SoC). We report a ten-channel peripheral nervous system (PNS) electroneurogram (ENG) signal acquisition SoC within an implantable package. Requiring only four off-chip capacitors, this SoC can be co-encapsulated with flexible nerve electrodes and a resonant coil antenna to form a 3.4 cm³ and 3.9 g implantable device for chronic ENG acquisition. This SoC is inductively powered and controlled through a resonant coil at 22 MHz and transmits the digitized neural signal through a near-infrared LED (NIR-LED). Fabricated in 0.18-μm CMOS, each amplifier channel exhibits an input referred noise of 1.9 μVrms and a noise efficiency factor (NEF) of 4.0 within the signal bandwidth of 5.5 kHz. Each amplifier channel within the SoC is digitized with 10-bit resolution at 17.5 ksps, and the total power consumption (SoC and NIR-LED) is 4.4 mW when the NIR-LED is driven at 3 Mb/s. An electrode impedance measurement circuit with <10% magnitude and <8° angle error for measuring impedances up to 1 MΩ is also incorporated in this SoC. This wireless, low noise ENG acquisition SoC package has been validated in vivo while implanted on a rodent to acquire ENG from its sciatic nerve.Keywords
Funding Information
- National Research Foundation Singapore (NRF-CRP-10-2012-01)
This publication has 38 references indexed in Scilit:
- A Compact, Low Input Capacitance Neural Recording AmplifierIEEE Transactions on Biomedical Circuits and Systems, 2013
- A translational platform for prototyping closed-loop neuromodulation systemsFrontiers in Neural Circuits, 2013
- Tunable high resistance voltage-controlled pseudo-resistor with wide input voltage swing capabilityElectronics Letters, 2011
- Decoding of grasping information from neural signals recorded using peripheral intrafascicular interfacesJournal of NeuroEngineering and Rehabilitation, 2011
- On the use of wavelet denoising and spike sorting techniques to process electroneurographic signals recorded using intraneural electrodesJournal of Neuroscience Methods, 2008
- Polytrodes: High-Density Silicon Electrode Arrays for Large-Scale Multiunit RecordingJournal of Neurophysiology, 2005
- Design of a low-noise preamplifier for nerve cuff electrode recordingIEEE Journal of Solid-State Circuits, 2003
- On the design and characterization of femtoampere current-mode circuitsIEEE Journal of Solid-State Circuits, 2003
- A BiCMOS low-distortion 8-MHz low-pass filterIEEE Journal of Solid-State Circuits, 1993
- Class E-A new class of high-efficiency tuned single-ended switching power amplifiersIEEE Journal of Solid-State Circuits, 1975