Gil Gerald Lasam Gammad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gil Gerald Lasam Gammad has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Shih-Cheng Yen
Department of Electrical and Computer Engineering, College of Design and Engineering, National University of Singapore, Singapore; Engineering Design and Innovation Centre, College of Design and Engineering, National University of Singapore, Singapore
6 shared publications - John S. Ho
Institute for Health Innovation and Technology, National University of Singapore, Singapore 117599, Singapore
4 shared publications - Kian Ann Ng
Engineering Cluster, Singapore Institute of Technology, Singapore 828608, Singapore
4 shared publications - Astrid Rusly
Department of Electrical and Computer Engineering, National University of Singapore, Singapore 117583, Singapore
3 shared publications - Jerald Yoo
Department of Electrical and Computer Engineering, Seoul National University, Seoul, South Korea
3 shared publications - Khay-Wai Leong
Department of Electrical and Computer Engineering, National University of Singapore, Singapore, Singapore
3 shared publications
Latest Publications
- 20 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (3) , 1085-1092
STEER: 3D Printed Guide for Nerve Regrowth Control and Neural Interface in Non-Human Primate Model
Objective: Peripheral neural interface (PNI) with a stable integration of synthetic elements with neural tissue is key for successful neuro-prosthetic applications. An inevitable phenomenon of reactive fibrosis is a primary hurdle for long term functionality of PNIs. This proof-of-concept study aimed to fabricate and test a novel, stable PNI that harnesses fibro-axonal outgrowth at the nerve end and includes fibrosis in the design. Methods: Two non-human primates were implanted with Substrate-guided, Tissue-Electrode Encapsulation and Integration (STEER) PNIs. The implant included a 3D printed guide that strove to steer the regrowing nerve towards encapsulation of the electrodes into a fibro-axonal tissue. After four months from implantation, we performed electrophysiological measurements to test STEERs functionality and examined the macro and micro- morphology of the outgrowth tissue. Results: We observed a highly structured fibro-axonal composite within the STEER PNI. A conduction of intracranially generated action potentials was successfully recorded across the neural interface. Immunohistology demonstrated uniquely configured laminae of myelinated axons encasing the implant. Conclusion: STEER PNI reconfigured the structure of the fibro-axonal tissue and facilitated long-term functionality and stability of the neural interface. Significance: The results point to the feasibility of our concept for creating a stable PNI with long-term electrophysiologic functionality by using simple design and materials.
- 20 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (3) , 1085-1092
STEER: 3D Printed Guide for Nerve Regrowth Control and Neural Interface in Non-Human Primate Model
Objective: Peripheral neural interface (PNI) with a stable integration of synthetic elements with neural tissue is key for successful neuro-prosthetic applications. An inevitable phenomenon of reactive fibrosis is a primary hurdle for long term functionality of PNIs. This proof-of-concept study aimed to fabricate and test a novel, stable PNI that harnesses fibro-axonal outgrowth at the nerve end and includes fibrosis in the design. Methods: Two non-human primates were implanted with Substrate-guided, Tissue-Electrode Encapsulation and Integration (STEER) PNIs. The implant included a 3D printed guide that strove to steer the regrowing nerve towards encapsulation of the electrodes into a fibro-axonal tissue. After four months from implantation, we performed electrophysiological measurements to test STEERs functionality and examined the macro and micro- morphology of the outgrowth tissue. Results: We observed a highly structured fibro-axonal composite within the STEER PNI. A conduction of intracranially generated action potentials was successfully recorded across the neural interface. Immunohistology demonstrated uniquely configured laminae of myelinated axons encasing the implant. Conclusion: STEER PNI reconfigured the structure of the fibro-axonal tissue and facilitated long-term functionality and stability of the neural interface. Significance: The results point to the feasibility of our concept for creating a stable PNI with long-term electrophysiologic functionality by using simple design and materials.
- 31 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 14 (6) , 1441
Erratum to “A 3-Mbps, 802.11g-Based EMG Recording System With Fully Implantable 5-Electrode EMG Acquisition Device” [Aug 20 889-902]
Corrections were made to the title in the above named paper.
- 31 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 14 (6) , 1441
Erratum to “A 3-Mbps, 802.11g-Based EMG Recording System With Fully Implantable 5-Electrode EMG Acquisition Device” [Aug 20 889-902]
Corrections were made to the title in the above named paper.
- Open Access
- 21 July 2020
- Published by Wiley in Advanced Materials
- Vol. 32 (29)
Photodynamic Therapy: A Flexi‐PEGDA Upconversion Implant for Wireless Brain Photodynamic Therapy (Adv. Mater. 29/2020)
- 21 July 2020
- Published by Wiley in Advanced Materials
- Vol. 32 (29)
Open AccessPhotodynamic Therapy: A Flexi‐PEGDA Upconversion Implant for Wireless Brain Photodynamic Therapy (Adv. Mater. 29/2020)
- 14 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 14 (4) , 889-902
A 3-Mbps, 802.11g-Based EMG Recording System With Fully Implantable 5-Electrode EMGxbrk Acquisition Device
We have developed a 5-electrode recording system that combines an implantable electromyography (EMG) device package with transcutaneous inductive power transmission, near-infrared (NIR) transcutaneous data telemetry and 3 Mbps Wi-Fi data acquisition for chronic EMG recording in vivo. This system comprises a hermetically-sealed single-chip, 5-electrode Implantable EMG Acquisition Device (IEAD), a custom external powering and Implant Telemetry Module (ITM), and a custom Wi-Fi-based Raspberry Pi-based Data Acquisition (RaspDAQ) and relay device. The external unit (ITM and RaspDAQ) is powered entirely by a single battery to achieve the objective of untethered EMG recording, for the convenience of clinicians and animal researchers. The IEAD acquires intramuscular EMG signals at 17.85 ksps/electrode while being powered transcutaneously by the ITM using 22 MHz near-field inductive coupling. The acquired EMG data is transmitted transcutaneously via NIR telemetry to the ITM, which in turn, transfers the data to the RaspDAQ for relaying to a laptop computer for display and storage. We have also validated the complete system by acquiring EMG signals from rodents for up to two months. Following the explantation of the devices, we have also conducted failure and histological analysis on the devices and the surrounding tissue, respectively.
- 14 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 14 (4) , 889-902
A 3-Mbps, 802.11g-Based EMG Recording System With Fully Implantable 5-Electrode EMGxbrk Acquisition Device
We have developed a 5-electrode recording system that combines an implantable electromyography (EMG) device package with transcutaneous inductive power transmission, near-infrared (NIR) transcutaneous data telemetry and 3 Mbps Wi-Fi data acquisition for chronic EMG recording in vivo. This system comprises a hermetically-sealed single-chip, 5-electrode Implantable EMG Acquisition Device (IEAD), a custom external powering and Implant Telemetry Module (ITM), and a custom Wi-Fi-based Raspberry Pi-based Data Acquisition (RaspDAQ) and relay device. The external unit (ITM and RaspDAQ) is powered entirely by a single battery to achieve the objective of untethered EMG recording, for the convenience of clinicians and animal researchers. The IEAD acquires intramuscular EMG signals at 17.85 ksps/electrode while being powered transcutaneously by the ITM using 22 MHz near-field inductive coupling. The acquired EMG data is transmitted transcutaneously via NIR telemetry to the ITM, which in turn, transfers the data to the RaspDAQ for relaying to a laptop computer for display and storage. We have also validated the complete system by acquiring EMG signals from rodents for up to two months. Following the explantation of the devices, we have also conducted failure and histological analysis on the devices and the surrounding tissue, respectively.
- Open Access
- 15 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 55 (10) , 2771-2780
A 15-Channel Orthogonal Code Chopping Instrumentation Amplifier for Area-Efficient, Low-Mismatch Bio-Signal Acquisition
This article presents a 15-channel orthogonal code chopping instrumentation amplifier (OCCIA) for an area-efficient and low gain-mismatch multi-channel bio-signal acquisition. Orthogonal codes directly modulate each channel and merge into a single signal for sharing IA, while performing dynamic offset compensation with low power consumption. Digitization-before-demodulation (DBD) transmits the combined modulated data directly, which alleviates ripple noise, and completely removes the demodulation and TX encoding overhead from the ASIC. The proposed OCCIA in 0.18-μm 1P6M CMOS, when compared with the recent multi-channel instrumentation amplifiers (IAs), shows the smallest area (0.019 mm²/Ch.), low gain mismatch (0.43%), with the lowest power consumption (1.97 μW/Ch.) and low crosstalk (<- 51.5 dB) at 490-Hz bandwidth.
- 15 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 55 (10) , 2771-2780
Open AccessA 15-Channel Orthogonal Code Chopping Instrumentation Amplifier for Area-Efficient, Low-Mismatch Bio-Signal Acquisition
This article presents a 15-channel orthogonal code chopping instrumentation amplifier (OCCIA) for an area-efficient and low gain-mismatch multi-channel bio-signal acquisition. Orthogonal codes directly modulate each channel and merge into a single signal for sharing IA, while performing dynamic offset compensation with low power consumption. Digitization-before-demodulation (DBD) transmits the combined modulated data directly, which alleviates ripple noise, and completely removes the demodulation and TX encoding overhead from the ASIC. The proposed OCCIA in 0.18-μm 1P6M CMOS, when compared with the recent multi-channel instrumentation amplifiers (IAs), shows the smallest area (0.019 mm²/Ch.), low gain mismatch (0.43%), with the lowest power consumption (1.97 μW/Ch.) and low crosstalk (<- 51.5 dB) at 490-Hz bandwidth.
- Open Access
Neuromodulation of pelvic nerve during early phase of spinal cord injury in rats using implantable prototype devices - a preliminary study
Objectives: The bladder becomes retentive during the early phase of spinal cord injury, and requires proper bladder management to prevent damage to the lower urinary tract and kidney. We investigated the effects of on-demand pelvic nerve stimulation on the areflexive bladder during the earliest phase of complete spinal cord injury in rats and the use of pelvic nerve signals as a proxy to estimate intravesical pressure for closed-loop applications. Materials and Methods: In order to stimulate the pelvic nerves in female Sprague-Dawley rats with complete spinal cord transection (T7 level), a flexible electrode was implanted unilaterally on pelvic nerve, and electrical stimulation was provided by a custom-built nerve stimulator. Stimulation-evoked voiding was monitored in the awake state while size, capacity and spontaneous contractions of the bladder were analysed under anaesthesia. Separately, recordings of the pelvic nerve signals, external urethral sphincter activity and intravesical pressure were performed in animals with intact and transected spinal cord under anaesthesia. Results: Successful pelvic nerve stimulation enabled more frequent voiding, reduced overdistension of bladder, and preserved non-voiding spontaneous bladder contractions. Typical bladder management protocol for SCI rats (manual expression every 8 – 12 hours) resulted in more severe bladder overdistention. Signal processing of the recorded extraneural pelvic nerve signals successfully reconstructed changes in intravesical pressure, demonstrating their use in estimating the fullness and contractions of the bladder. Conclusions: The preliminary results suggest that pelvic nerve stimulators can serve as an alternative method for frequent emptying of the areflexive bladder. Simultaneous recording of the same pelvic nerve will be useful for development of a closed-loop neuroprosthesis.
Open AccessNeuromodulation of pelvic nerve during early phase of spinal cord injury in rats using implantable prototype devices - a preliminary study
Objectives: The bladder becomes retentive during the early phase of spinal cord injury, and requires proper bladder management to prevent damage to the lower urinary tract and kidney. We investigated the effects of on-demand pelvic nerve stimulation on the areflexive bladder during the earliest phase of complete spinal cord injury in rats and the use of pelvic nerve signals as a proxy to estimate intravesical pressure for closed-loop applications. Materials and Methods: In order to stimulate the pelvic nerves in female Sprague-Dawley rats with complete spinal cord transection (T7 level), a flexible electrode was implanted unilaterally on pelvic nerve, and electrical stimulation was provided by a custom-built nerve stimulator. Stimulation-evoked voiding was monitored in the awake state while size, capacity and spontaneous contractions of the bladder were analysed under anaesthesia. Separately, recordings of the pelvic nerve signals, external urethral sphincter activity and intravesical pressure were performed in animals with intact and transected spinal cord under anaesthesia. Results: Successful pelvic nerve stimulation enabled more frequent voiding, reduced overdistension of bladder, and preserved non-voiding spontaneous bladder contractions. Typical bladder management protocol for SCI rats (manual expression every 8 – 12 hours) resulted in more severe bladder overdistention. Signal processing of the recorded extraneural pelvic nerve signals successfully reconstructed changes in intravesical pressure, demonstrating their use in estimating the fullness and contractions of the bladder. Conclusions: The preliminary results suggest that pelvic nerve stimulators can serve as an alternative method for frequent emptying of the areflexive bladder. Simultaneous recording of the same pelvic nerve will be useful for development of a closed-loop neuroprosthesis.
- 7 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 54 (8) , 2266-2280
A Wireless Multi-Channel Peripheral Nerve Signal Acquisition System-on-Chip
The adoption of chronic implantable peripheral nerve-based prosthetic devices is currently hampered by the lack of a highly integrated neural signal acquisition system-on-chip (SoC). We report a ten-channel peripheral nervous system (PNS) electroneurogram (ENG) signal acquisition SoC within an implantable package. Requiring only four off-chip capacitors, this SoC can be co-encapsulated with flexible nerve electrodes and a resonant coil antenna to form a 3.4 cm³ and 3.9 g implantable device for chronic ENG acquisition. This SoC is inductively powered and controlled through a resonant coil at 22 MHz and transmits the digitized neural signal through a near-infrared LED (NIR-LED). Fabricated in 0.18-μm CMOS, each amplifier channel exhibits an input referred noise of 1.9 μVrms and a noise efficiency factor (NEF) of 4.0 within the signal bandwidth of 5.5 kHz. Each amplifier channel within the SoC is digitized with 10-bit resolution at 17.5 ksps, and the total power consumption (SoC and NIR-LED) is 4.4 mW when the NIR-LED is driven at 3 Mb/s. An electrode impedance measurement circuit with <10% magnitude and <8° angle error for measuring impedances up to 1 MΩ is also incorporated in this SoC. This wireless, low noise ENG acquisition SoC package has been validated in vivo while implanted on a rodent to acquire ENG from its sciatic nerve.
- 7 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 54 (8) , 2266-2280
A Wireless Multi-Channel Peripheral Nerve Signal Acquisition System-on-Chip
The adoption of chronic implantable peripheral nerve-based prosthetic devices is currently hampered by the lack of a highly integrated neural signal acquisition system-on-chip (SoC). We report a ten-channel peripheral nervous system (PNS) electroneurogram (ENG) signal acquisition SoC within an implantable package. Requiring only four off-chip capacitors, this SoC can be co-encapsulated with flexible nerve electrodes and a resonant coil antenna to form a 3.4 cm³ and 3.9 g implantable device for chronic ENG acquisition. This SoC is inductively powered and controlled through a resonant coil at 22 MHz and transmits the digitized neural signal through a near-infrared LED (NIR-LED). Fabricated in 0.18-μm CMOS, each amplifier channel exhibits an input referred noise of 1.9 μVrms and a noise efficiency factor (NEF) of 4.0 within the signal bandwidth of 5.5 kHz. Each amplifier channel within the SoC is digitized with 10-bit resolution at 17.5 ksps, and the total power consumption (SoC and NIR-LED) is 4.4 mW when the NIR-LED is driven at 3 Mb/s. An electrode impedance measurement circuit with <10% magnitude and <8° angle error for measuring impedances up to 1 MΩ is also incorporated in this SoC. This wireless, low noise ENG acquisition SoC package has been validated in vivo while implanted on a rodent to acquire ENG from its sciatic nerve.