Astrid Rusly
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Astrid Rusly has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Kian Ann Ng
Engineering Cluster, Singapore Institute of Technology, Singapore 828608, Singapore
4 shared publications - Gil Gerald Lasam Gammad
National University of Singapore, 37580 Singapore, Singapore
3 shared publications - Shih-Cheng Yen
Department of Electrical and Computer Engineering, College of Design and Engineering, National University of Singapore, Singapore; Engineering Design and Innovation Centre, College of Design and Engineering, National University of Singapore, Singapore
3 shared publications - Jerald Yoo
Department of Electrical and Computer Engineering, Seoul National University, Seoul, South Korea
2 shared publications - John S. Ho
Institute for Health Innovation and Technology, National University of Singapore, Singapore 117599, Singapore
2 shared publications - Khay-Wai Leong
Department of Electrical and Computer Engineering, National University of Singapore, Singapore, Singapore
2 shared publications
Latest Publications
- Open Access
- 1 May 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (18) , eaec9803
SkinECG: An orthogonal remote powering wearable skin-like sensor
The Internet of Things (IoT) era witnessed a surge in wearable devices for the human body, each requiring a power source that supports long-term operation. However, batteries are depletable and require replacement, while the effectiveness of energy-harvesting techniques is location specific. We developed the SkinECG system, an orthogonal remote powering skin-like electrocardiogram (ECG) sensor. It is powered by body-coupled powering (BCP) using power acquired optimally via suitable energy harvesters at different locations on the human body, solving the location mismatch between the energy-harvesting source and sensor. The remote Orthogonal Energy Harvesting Network (O-EHN) effectively transfers power from multiple energy-harvesting sources without internode interference and cancellation. We demonstrated the 0.71-mm-thin, flexible SkinECG system that conforms to the human chest and detects ECG signals without any cumbersome batteries or directly connected power for long-term health monitoring.
- 1 May 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (18) , eaec9803
Open AccessSkinECG: An orthogonal remote powering wearable skin-like sensor
The Internet of Things (IoT) era witnessed a surge in wearable devices for the human body, each requiring a power source that supports long-term operation. However, batteries are depletable and require replacement, while the effectiveness of energy-harvesting techniques is location specific. We developed the SkinECG system, an orthogonal remote powering skin-like electrocardiogram (ECG) sensor. It is powered by body-coupled powering (BCP) using power acquired optimally via suitable energy harvesters at different locations on the human body, solving the location mismatch between the energy-harvesting source and sensor. The remote Orthogonal Energy Harvesting Network (O-EHN) effectively transfers power from multiple energy-harvesting sources without internode interference and cancellation. We demonstrated the 0.71-mm-thin, flexible SkinECG system that conforms to the human chest and detects ECG signals without any cumbersome batteries or directly connected power for long-term health monitoring.
- 31 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 14 (6) , 1441
Erratum to “A 3-Mbps, 802.11g-Based EMG Recording System With Fully Implantable 5-Electrode EMG Acquisition Device” [Aug 20 889-902]
Corrections were made to the title in the above named paper.
- 31 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 14 (6) , 1441
Erratum to “A 3-Mbps, 802.11g-Based EMG Recording System With Fully Implantable 5-Electrode EMG Acquisition Device” [Aug 20 889-902]
Corrections were made to the title in the above named paper.
- Open Access
Neuromodulation of pelvic nerve during early phase of spinal cord injury in rats using implantable prototype devices - a preliminary study
Objectives: The bladder becomes retentive during the early phase of spinal cord injury, and requires proper bladder management to prevent damage to the lower urinary tract and kidney. We investigated the effects of on-demand pelvic nerve stimulation on the areflexive bladder during the earliest phase of complete spinal cord injury in rats and the use of pelvic nerve signals as a proxy to estimate intravesical pressure for closed-loop applications. Materials and Methods: In order to stimulate the pelvic nerves in female Sprague-Dawley rats with complete spinal cord transection (T7 level), a flexible electrode was implanted unilaterally on pelvic nerve, and electrical stimulation was provided by a custom-built nerve stimulator. Stimulation-evoked voiding was monitored in the awake state while size, capacity and spontaneous contractions of the bladder were analysed under anaesthesia. Separately, recordings of the pelvic nerve signals, external urethral sphincter activity and intravesical pressure were performed in animals with intact and transected spinal cord under anaesthesia. Results: Successful pelvic nerve stimulation enabled more frequent voiding, reduced overdistension of bladder, and preserved non-voiding spontaneous bladder contractions. Typical bladder management protocol for SCI rats (manual expression every 8 – 12 hours) resulted in more severe bladder overdistention. Signal processing of the recorded extraneural pelvic nerve signals successfully reconstructed changes in intravesical pressure, demonstrating their use in estimating the fullness and contractions of the bladder. Conclusions: The preliminary results suggest that pelvic nerve stimulators can serve as an alternative method for frequent emptying of the areflexive bladder. Simultaneous recording of the same pelvic nerve will be useful for development of a closed-loop neuroprosthesis.
Open AccessNeuromodulation of pelvic nerve during early phase of spinal cord injury in rats using implantable prototype devices - a preliminary study
Objectives: The bladder becomes retentive during the early phase of spinal cord injury, and requires proper bladder management to prevent damage to the lower urinary tract and kidney. We investigated the effects of on-demand pelvic nerve stimulation on the areflexive bladder during the earliest phase of complete spinal cord injury in rats and the use of pelvic nerve signals as a proxy to estimate intravesical pressure for closed-loop applications. Materials and Methods: In order to stimulate the pelvic nerves in female Sprague-Dawley rats with complete spinal cord transection (T7 level), a flexible electrode was implanted unilaterally on pelvic nerve, and electrical stimulation was provided by a custom-built nerve stimulator. Stimulation-evoked voiding was monitored in the awake state while size, capacity and spontaneous contractions of the bladder were analysed under anaesthesia. Separately, recordings of the pelvic nerve signals, external urethral sphincter activity and intravesical pressure were performed in animals with intact and transected spinal cord under anaesthesia. Results: Successful pelvic nerve stimulation enabled more frequent voiding, reduced overdistension of bladder, and preserved non-voiding spontaneous bladder contractions. Typical bladder management protocol for SCI rats (manual expression every 8 – 12 hours) resulted in more severe bladder overdistention. Signal processing of the recorded extraneural pelvic nerve signals successfully reconstructed changes in intravesical pressure, demonstrating their use in estimating the fullness and contractions of the bladder. Conclusions: The preliminary results suggest that pelvic nerve stimulators can serve as an alternative method for frequent emptying of the areflexive bladder. Simultaneous recording of the same pelvic nerve will be useful for development of a closed-loop neuroprosthesis.
- 7 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 54 (8) , 2266-2280
A Wireless Multi-Channel Peripheral Nerve Signal Acquisition System-on-Chip
The adoption of chronic implantable peripheral nerve-based prosthetic devices is currently hampered by the lack of a highly integrated neural signal acquisition system-on-chip (SoC). We report a ten-channel peripheral nervous system (PNS) electroneurogram (ENG) signal acquisition SoC within an implantable package. Requiring only four off-chip capacitors, this SoC can be co-encapsulated with flexible nerve electrodes and a resonant coil antenna to form a 3.4 cm³ and 3.9 g implantable device for chronic ENG acquisition. This SoC is inductively powered and controlled through a resonant coil at 22 MHz and transmits the digitized neural signal through a near-infrared LED (NIR-LED). Fabricated in 0.18-μm CMOS, each amplifier channel exhibits an input referred noise of 1.9 μVrms and a noise efficiency factor (NEF) of 4.0 within the signal bandwidth of 5.5 kHz. Each amplifier channel within the SoC is digitized with 10-bit resolution at 17.5 ksps, and the total power consumption (SoC and NIR-LED) is 4.4 mW when the NIR-LED is driven at 3 Mb/s. An electrode impedance measurement circuit with <10% magnitude and <8° angle error for measuring impedances up to 1 MΩ is also incorporated in this SoC. This wireless, low noise ENG acquisition SoC package has been validated in vivo while implanted on a rodent to acquire ENG from its sciatic nerve.
- 7 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 54 (8) , 2266-2280
A Wireless Multi-Channel Peripheral Nerve Signal Acquisition System-on-Chip
The adoption of chronic implantable peripheral nerve-based prosthetic devices is currently hampered by the lack of a highly integrated neural signal acquisition system-on-chip (SoC). We report a ten-channel peripheral nervous system (PNS) electroneurogram (ENG) signal acquisition SoC within an implantable package. Requiring only four off-chip capacitors, this SoC can be co-encapsulated with flexible nerve electrodes and a resonant coil antenna to form a 3.4 cm³ and 3.9 g implantable device for chronic ENG acquisition. This SoC is inductively powered and controlled through a resonant coil at 22 MHz and transmits the digitized neural signal through a near-infrared LED (NIR-LED). Fabricated in 0.18-μm CMOS, each amplifier channel exhibits an input referred noise of 1.9 μVrms and a noise efficiency factor (NEF) of 4.0 within the signal bandwidth of 5.5 kHz. Each amplifier channel within the SoC is digitized with 10-bit resolution at 17.5 ksps, and the total power consumption (SoC and NIR-LED) is 4.4 mW when the NIR-LED is driven at 3 Mb/s. An electrode impedance measurement circuit with <10% magnitude and <8° angle error for measuring impedances up to 1 MΩ is also incorporated in this SoC. This wireless, low noise ENG acquisition SoC package has been validated in vivo while implanted on a rodent to acquire ENG from its sciatic nerve.