Abstract
Study Design: Retrospective case series. Objective: To evaluate the accuracy and safety of robotic-assisted cervical pedicle screw placement using the SpineVidya C-TEK system with uniform 5.5 mm rods across the cervicothoracic junction. Summary of Background Data: The cervicothoracic junction (CTJ) represents a biomechanical transition zone where traditional cervical constructs require rod diameter transitions, introducing mechanical weakness. The C-TEK system features an enlarged tulip design accommodating 5.5 mm rods with 4.0 mm diameter cervical pedicle screws, eliminating the need for tapered rods or connectors at the CTJ. Methods: Twenty-six consecutive patients (282 screws) underwent robotic-assisted C-TEK cervical pedicle screw placement crossing the CTJ between April 2024 and June 2025. All procedures utilized the MazorX Stealth Edition robotic system with O-arm intraoperative CT imaging. Two blinded observers assessed screw accuracy using the Gertzbein-Robbins classification. Clinical outcomes and complications were evaluated. Results: Mean age was 54.1 years. In this preliminary series, all 282 screws achieved clinically acceptable placement (grades A–B; 100% in this cohort). Perfect placement (grade A) was achieved in 276 screws (97.9%), with grade B breach in 6 screws (2.1%). No grade C, D, or E breaches occurred. At the cervicothoracic junction levels (C7, T1, T2), 78 screws maintained clinically acceptable accuracy. Interobserver reliability was excellent (κ=0.94). No vertebral artery injuries, permanent neurological deficits, or hardware failures occurred. Illustrative cases demonstrated feasibility across diverse pathologies including dropped head syndrome, dystrophic scoliosis, and revision scenarios. Conclusions: Robotic-assisted C-TEK cervical pedicle screw placement demonstrates high accuracy and technical feasibility for uniform 5.5 mm rod constructs crossing the CTJ without rod diameter transitions or connectors. These preliminary results from a single-center experience support further investigation, including comparative studies with traditional dual-diameter systems. Level of Evidence: Level IV.Keywords
This publication has 29 references indexed in Scilit:
- Robot-assisted technique versus freehand technique for spine surgery: an umbrella reviewAnnals of Medicine, 2025
- Robotic-guided placement of cervical pedicle screws: feasibility and accuracyEuropean Spine Journal, 2022
- To cross or not to cross the cervicothoracic junction in multilevel posterior cervical fusion: a systematic review and meta-analysisThe Spine Journal, 2022
- Next-Generation Robotic Spine Surgery: First Report on Feasibility, Safety, and Learning CurveOperative Neurosurgery, 2018
- Pedicle Screw Revision in Robot-Guided, Navigated, and Freehand Thoracolumbar Instrumentation: A Systematic Review and Meta-AnalysisWorld Neurosurgery, 2018
- A multicenter study on accuracy and complications of freehand placement of cervical pedicle screws under lateral fluoroscopy in different pathological conditions: CT-based evaluation of more than 1,000 screwsEuropean Spine Journal, 2014
- What Is the Learning Curve for Robotic-assisted Pedicle Screw Placement in Spine Surgery?Clinical Orthopaedics and Related Research, 2014
- Placement and complications of cervical pedicle screws in 144 cervical trauma patients using pedicle axis view techniques by fluoroscopeEuropean Spine Journal, 2009
- Cervical pedicle screw placement: feasibility and accuracy of two new insertion techniques based on morphometric dataEuropean Spine Journal, 2006
- Transpedicle Screw Fixation of the Cervical SpineClinical Orthopaedics and Related Research, 1999