Balamurugan Thirugnanam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Balamurugan Thirugnanam has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Vidyadhara Srinivasa
Manipal Institute of Robotic Spine Surgery, Manipal Comprehensive Spine Care Center, Manipal Hospital, Bangalore, India
16 shared publications - Abhishek Soni
Manipal Institute of Robotic Spine Surgery, Manipal Comprehensive Spine Care Centre, Manipal Hospital, Bangalore, India
15 shared publications - Madhava Pai Kanhangad
Department of Orthopaedics, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, India
8 shared publications - R. Dinesh Iyer
Manipal Institute of Robotic Spine Surgery, Manipal Comprehensive Spine Care Centre, Manipal Hospital, Bangalore, India
5 shared publications - Akhil Xavier Joseph
Manipal Institute of Robotic Spine Surgery, Manipal Comprehensive Spine Care Centre, Manipal Hospital, Bangalore, India
3 shared publications - Sharath Kumar Rao
Department of Orthopaedics, Kasturba Medical College, Manipal, India
3 shared publications
Latest Publications
- 10 November 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 1194
Beyond accuracy: is reproducibility the case for robotics in spinal trauma surgery?
- 10 November 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 1194
Beyond accuracy: is reproducibility the case for robotics in spinal trauma surgery?
- 12 August 2026
- Published by Wolters Kluwer Health in Clinical Spine Surgery
Robotic-Assisted Cervical Pedicle Screw Placement With Uniform 5.5 mm Rods Crossing the Cervicothoracic Junction
Study Design: Retrospective case series. Objective: To evaluate the accuracy and safety of robotic-assisted cervical pedicle screw placement using the SpineVidya C-TEK system with uniform 5.5 mm rods across the cervicothoracic junction. Summary of Background Data: The cervicothoracic junction (CTJ) represents a biomechanical transition zone where traditional cervical constructs require rod diameter transitions, introducing mechanical weakness. The C-TEK system features an enlarged tulip design accommodating 5.5 mm rods with 4.0 mm diameter cervical pedicle screws, eliminating the need for tapered rods or connectors at the CTJ. Methods: Twenty-six consecutive patients (282 screws) underwent robotic-assisted C-TEK cervical pedicle screw placement crossing the CTJ between April 2024 and June 2025. All procedures utilized the MazorX Stealth Edition robotic system with O-arm intraoperative CT imaging. Two blinded observers assessed screw accuracy using the Gertzbein-Robbins classification. Clinical outcomes and complications were evaluated. Results: Mean age was 54.1 years. In this preliminary series, all 282 screws achieved clinically acceptable placement (grades A–B; 100% in this cohort). Perfect placement (grade A) was achieved in 276 screws (97.9%), with grade B breach in 6 screws (2.1%). No grade C, D, or E breaches occurred. At the cervicothoracic junction levels (C7, T1, T2), 78 screws maintained clinically acceptable accuracy. Interobserver reliability was excellent (κ=0.94). No vertebral artery injuries, permanent neurological deficits, or hardware failures occurred. Illustrative cases demonstrated feasibility across diverse pathologies including dropped head syndrome, dystrophic scoliosis, and revision scenarios. Conclusions: Robotic-assisted C-TEK cervical pedicle screw placement demonstrates high accuracy and technical feasibility for uniform 5.5 mm rod constructs crossing the CTJ without rod diameter transitions or connectors. These preliminary results from a single-center experience support further investigation, including comparative studies with traditional dual-diameter systems. Level of Evidence: Level IV.
- 12 August 2026
- Published by Wolters Kluwer Health in Clinical Spine Surgery
Robotic-Assisted Cervical Pedicle Screw Placement With Uniform 5.5 mm Rods Crossing the Cervicothoracic Junction
Study Design: Retrospective case series. Objective: To evaluate the accuracy and safety of robotic-assisted cervical pedicle screw placement using the SpineVidya C-TEK system with uniform 5.5 mm rods across the cervicothoracic junction. Summary of Background Data: The cervicothoracic junction (CTJ) represents a biomechanical transition zone where traditional cervical constructs require rod diameter transitions, introducing mechanical weakness. The C-TEK system features an enlarged tulip design accommodating 5.5 mm rods with 4.0 mm diameter cervical pedicle screws, eliminating the need for tapered rods or connectors at the CTJ. Methods: Twenty-six consecutive patients (282 screws) underwent robotic-assisted C-TEK cervical pedicle screw placement crossing the CTJ between April 2024 and June 2025. All procedures utilized the MazorX Stealth Edition robotic system with O-arm intraoperative CT imaging. Two blinded observers assessed screw accuracy using the Gertzbein-Robbins classification. Clinical outcomes and complications were evaluated. Results: Mean age was 54.1 years. In this preliminary series, all 282 screws achieved clinically acceptable placement (grades A–B; 100% in this cohort). Perfect placement (grade A) was achieved in 276 screws (97.9%), with grade B breach in 6 screws (2.1%). No grade C, D, or E breaches occurred. At the cervicothoracic junction levels (C7, T1, T2), 78 screws maintained clinically acceptable accuracy. Interobserver reliability was excellent (κ=0.94). No vertebral artery injuries, permanent neurological deficits, or hardware failures occurred. Illustrative cases demonstrated feasibility across diverse pathologies including dropped head syndrome, dystrophic scoliosis, and revision scenarios. Conclusions: Robotic-assisted C-TEK cervical pedicle screw placement demonstrates high accuracy and technical feasibility for uniform 5.5 mm rod constructs crossing the CTJ without rod diameter transitions or connectors. These preliminary results from a single-center experience support further investigation, including comparative studies with traditional dual-diameter systems. Level of Evidence: Level IV.
- 1 July 2026
- Published by Elsevier in Journal of Orthopaedics
- Vol. 77, 133-141
Balanced Turbo Field Echo MRI as a radiation-free adjunct for spinal bone imaging: A prospective study of 526 patients
- 1 July 2026
- Published by Elsevier in Journal of Orthopaedics
- Vol. 77, 133-141
Balanced Turbo Field Echo MRI as a radiation-free adjunct for spinal bone imaging: A prospective study of 526 patients
- Open Access
- 28 February 2026
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 20 (1) , 216-218
Response to the letter to the editor: Beyond fixation: computational and motion-integrated perspectives on pinless robot-assisted spine surgery
- 28 February 2026
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 20 (1) , 216-218
Open AccessResponse to the letter to the editor: Beyond fixation: computational and motion-integrated perspectives on pinless robot-assisted spine surgery
- 13 January 2026
- Published by Elsevier in Journal of Orthopaedics
- Vol. 74, 214-219
Robotic S2Alar iliac screw placement: Comparing conventional and robot assisted minimally invasive techniques
- 13 January 2026
- Published by Elsevier in Journal of Orthopaedics
- Vol. 74, 214-219
Robotic S2Alar iliac screw placement: Comparing conventional and robot assisted minimally invasive techniques
- Open Access
- 12 November 2025
- Published by SAGE Publications in Global Spine Journal
- Vol. 16 (5) , 2172-2180
Superior Metal Artifact Reduction With MAVRIC-SL Versus STIR in Lumbar Spine Instrumentation: A Retrospective Analysis of 84 Patients
Study Design: Retrospective Comparative Study. Objectives: To evaluate Multi-Acquisition Variable-Resonance Image Combination Selective (MAVRIC-SL) versus conventional Short-Tau Inversion Recovery (STIR) sequences for metal artifact reduction and diagnostic capability in patients with lumbar titanium instrumentation. Methods: 84 patients with implants in lumbar spine (mean age 54.3 ± 14.7 years; 52.4% male), who underwent both STIR and MAVRIC-SL MRI at 1.5 T. A neuroradiologist and spine surgeon independently measured signal loss areas and evaluated geometric distortion and neural structure visibility using standardized scales. Statistical analysis included paired t-tests and Wilcoxon signed-rank tests with Bonferroni correction ( P < 0.01). Results: MAVRIC-SL reduced signal loss area by 39.1% compared to STIR (0.809 ± 0.205 cm 2 vs 1.356 ± 0.266 cm 2 , P < 0.001, Cohen’s d = 2.04). Neural structure visibility showed substantial improvement: axial neural foramina (96.4% vs 0%), sagittal neural foramina (96.4% vs 7.1%), and sagittal spinal cord (98.8% vs 14.3%), all P < 0.001. Posterior vertebral border clarity improved from 33.3% to 94.0% ( P < 0.001). Conclusions: MAVRIC-SL provides superior metal artifact reduction and significantly improves neural structure visualization in lumbar spine instrumentation, with effect sizes among the largest reported in spine imaging studies. These improvements justify the longer acquisition time for symptomatic patients requiring detailed evaluation.
- 12 November 2025
- Published by SAGE Publications in Global Spine Journal
- Vol. 16 (5) , 2172-2180
Open AccessSuperior Metal Artifact Reduction With MAVRIC-SL Versus STIR in Lumbar Spine Instrumentation: A Retrospective Analysis of 84 Patients
Study Design: Retrospective Comparative Study. Objectives: To evaluate Multi-Acquisition Variable-Resonance Image Combination Selective (MAVRIC-SL) versus conventional Short-Tau Inversion Recovery (STIR) sequences for metal artifact reduction and diagnostic capability in patients with lumbar titanium instrumentation. Methods: 84 patients with implants in lumbar spine (mean age 54.3 ± 14.7 years; 52.4% male), who underwent both STIR and MAVRIC-SL MRI at 1.5 T. A neuroradiologist and spine surgeon independently measured signal loss areas and evaluated geometric distortion and neural structure visibility using standardized scales. Statistical analysis included paired t-tests and Wilcoxon signed-rank tests with Bonferroni correction ( P < 0.01). Results: MAVRIC-SL reduced signal loss area by 39.1% compared to STIR (0.809 ± 0.205 cm 2 vs 1.356 ± 0.266 cm 2 , P < 0.001, Cohen’s d = 2.04). Neural structure visibility showed substantial improvement: axial neural foramina (96.4% vs 0%), sagittal neural foramina (96.4% vs 7.1%), and sagittal spinal cord (98.8% vs 14.3%), all P < 0.001. Posterior vertebral border clarity improved from 33.3% to 94.0% ( P < 0.001). Conclusions: MAVRIC-SL provides superior metal artifact reduction and significantly improves neural structure visualization in lumbar spine instrumentation, with effect sizes among the largest reported in spine imaging studies. These improvements justify the longer acquisition time for symptomatic patients requiring detailed evaluation.
- Open Access
- 31 October 2025
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 19 (5) , 689-697
Evaluating the feasibility of pinless robot-assisted spine surgery: a prospective study of 750 cases and 3,924 screws in the thoracolumbar spine in India
Study Design: This single-center prospective study compared pin-mounted and pinless robot-assisted techniques for thoracolumbar pedicle screw placement.Purpose: To evaluate the feasibility, accuracy, and safety of a novel pinless technique in comparison to the traditional pin-mounted method in thoracolumbar fusion surgery.Overview of Literature: Robot-assisted spine surgery has enhanced the precision of pedicle screw placement and reduced radiation exposure. While conventional pin-mounted techniques are effective, they can lead to hardware-related complications. Emerging evidence indicates that eliminating bone-mounted fixation could streamline the surgical workflow without compromising accuracy or safety.Methods: A total of 750 consecutive patients who underwent robot-assisted thoracolumbar fusion were enrolled. Two groups were defined: 200 cases (890 screws) using the pin-mounted approach and 550 cases (3,034 screws) utilizing the pinless method. All procedures employed intraoperative computed tomography imaging and a standardized protocol with a table-mounted robotic system. Screw accuracy was assessed using the Gertzbein-Robbins grading system, with grades A and B classified as acceptable. Secondary parameters, including operative time, blood loss, and radiation exposure, were also recorded.Results: The pin-mounted group achieved an overall pedicle screw accuracy of 99.55% compared to 99.40% in the pinless group (p >0.05). There were four breaches in the pin-mounted group and 18 breaches in the pinless group, all of which were revised intraoperatively, with no permanent neurovascular injuries or major complications reported. Blood loss and radiation exposure were similar between the groups.Conclusions: The pinless robot-assisted pedicle screw placement technique demonstrates accuracy and safety comparable to the traditional pin-mounted method. By eliminating bone-mounted fixation, this approach simplifies the surgical workflow and reduces hardwarerelated complications, making it an effective alternative for thoracolumbar fusion surgery.
- 31 October 2025
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 19 (5) , 689-697
Open AccessEvaluating the feasibility of pinless robot-assisted spine surgery: a prospective study of 750 cases and 3,924 screws in the thoracolumbar spine in India
Study Design: This single-center prospective study compared pin-mounted and pinless robot-assisted techniques for thoracolumbar pedicle screw placement.Purpose: To evaluate the feasibility, accuracy, and safety of a novel pinless technique in comparison to the traditional pin-mounted method in thoracolumbar fusion surgery.Overview of Literature: Robot-assisted spine surgery has enhanced the precision of pedicle screw placement and reduced radiation exposure. While conventional pin-mounted techniques are effective, they can lead to hardware-related complications. Emerging evidence indicates that eliminating bone-mounted fixation could streamline the surgical workflow without compromising accuracy or safety.Methods: A total of 750 consecutive patients who underwent robot-assisted thoracolumbar fusion were enrolled. Two groups were defined: 200 cases (890 screws) using the pin-mounted approach and 550 cases (3,034 screws) utilizing the pinless method. All procedures employed intraoperative computed tomography imaging and a standardized protocol with a table-mounted robotic system. Screw accuracy was assessed using the Gertzbein-Robbins grading system, with grades A and B classified as acceptable. Secondary parameters, including operative time, blood loss, and radiation exposure, were also recorded.Results: The pin-mounted group achieved an overall pedicle screw accuracy of 99.55% compared to 99.40% in the pinless group (p >0.05). There were four breaches in the pin-mounted group and 18 breaches in the pinless group, all of which were revised intraoperatively, with no permanent neurovascular injuries or major complications reported. Blood loss and radiation exposure were similar between the groups.Conclusions: The pinless robot-assisted pedicle screw placement technique demonstrates accuracy and safety comparable to the traditional pin-mounted method. By eliminating bone-mounted fixation, this approach simplifies the surgical workflow and reduces hardwarerelated complications, making it an effective alternative for thoracolumbar fusion surgery.
- 29 October 2025
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 71, 103247
Robot-assistance in revision thoracolumbar fusion surgeries – Prospective study of 64 patients
- 29 October 2025
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 71, 103247
Robot-assistance in revision thoracolumbar fusion surgeries – Prospective study of 64 patients
- Open Access
- 25 October 2025
- Published by Elsevier in Journal of Orthopaedic Reports
- Vol. 5 (3)
Prevalence, types and radiological features of thoracolumbar transitional vertebra - a CT based cross sectional study
- 25 October 2025
- Published by Elsevier in Journal of Orthopaedic Reports
- Vol. 5 (3)
Open AccessPrevalence, types and radiological features of thoracolumbar transitional vertebra - a CT based cross sectional study