Vidyadhara Srinivasa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Vidyadhara Srinivasa has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Abhishek Soni
Manipal Institute of Robotic Spine Surgery, Manipal Comprehensive Spine Care Centre, Manipal Hospital, Bangalore, India
17 shared publications - Balamurugan Thirugnanam
Manipal Institute of Robotic Spine Surgery, Manipal Comprehensive Spine Care Centre, Manipal Hospital, Bangalore, India
16 shared publications Abhishek Soni
Manipal Institute of Robotic Spine Surgery, Manipal Comprehensive Spine Care Center, Manipal Hospital, Bangalore, India
11 shared publications- Sharath Kumar Rao
Department of Orthopaedics, Kasturba Medical College, Manipal, India
11 shared publications - Madhava Pai Kanhangad
Department of Orthopaedics, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, India
8 shared publications Alia Vidyadhara
Department of Spine Anesthesia, Manipal Comprehensive Spine Care Center, Manipal Hospital, Bengaluru, Karnataka, India
7 shared publications
Latest Publications
- 10 November 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 1194
Beyond accuracy: is reproducibility the case for robotics in spinal trauma surgery?
- 10 November 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 1194
Beyond accuracy: is reproducibility the case for robotics in spinal trauma surgery?
- 12 August 2026
- Published by Wolters Kluwer Health in Clinical Spine Surgery
Robotic-Assisted Cervical Pedicle Screw Placement With Uniform 5.5 mm Rods Crossing the Cervicothoracic Junction
Study Design: Retrospective case series. Objective: To evaluate the accuracy and safety of robotic-assisted cervical pedicle screw placement using the SpineVidya C-TEK system with uniform 5.5 mm rods across the cervicothoracic junction. Summary of Background Data: The cervicothoracic junction (CTJ) represents a biomechanical transition zone where traditional cervical constructs require rod diameter transitions, introducing mechanical weakness. The C-TEK system features an enlarged tulip design accommodating 5.5 mm rods with 4.0 mm diameter cervical pedicle screws, eliminating the need for tapered rods or connectors at the CTJ. Methods: Twenty-six consecutive patients (282 screws) underwent robotic-assisted C-TEK cervical pedicle screw placement crossing the CTJ between April 2024 and June 2025. All procedures utilized the MazorX Stealth Edition robotic system with O-arm intraoperative CT imaging. Two blinded observers assessed screw accuracy using the Gertzbein-Robbins classification. Clinical outcomes and complications were evaluated. Results: Mean age was 54.1 years. In this preliminary series, all 282 screws achieved clinically acceptable placement (grades A–B; 100% in this cohort). Perfect placement (grade A) was achieved in 276 screws (97.9%), with grade B breach in 6 screws (2.1%). No grade C, D, or E breaches occurred. At the cervicothoracic junction levels (C7, T1, T2), 78 screws maintained clinically acceptable accuracy. Interobserver reliability was excellent (κ=0.94). No vertebral artery injuries, permanent neurological deficits, or hardware failures occurred. Illustrative cases demonstrated feasibility across diverse pathologies including dropped head syndrome, dystrophic scoliosis, and revision scenarios. Conclusions: Robotic-assisted C-TEK cervical pedicle screw placement demonstrates high accuracy and technical feasibility for uniform 5.5 mm rod constructs crossing the CTJ without rod diameter transitions or connectors. These preliminary results from a single-center experience support further investigation, including comparative studies with traditional dual-diameter systems. Level of Evidence: Level IV.
- 12 August 2026
- Published by Wolters Kluwer Health in Clinical Spine Surgery
Robotic-Assisted Cervical Pedicle Screw Placement With Uniform 5.5 mm Rods Crossing the Cervicothoracic Junction
Study Design: Retrospective case series. Objective: To evaluate the accuracy and safety of robotic-assisted cervical pedicle screw placement using the SpineVidya C-TEK system with uniform 5.5 mm rods across the cervicothoracic junction. Summary of Background Data: The cervicothoracic junction (CTJ) represents a biomechanical transition zone where traditional cervical constructs require rod diameter transitions, introducing mechanical weakness. The C-TEK system features an enlarged tulip design accommodating 5.5 mm rods with 4.0 mm diameter cervical pedicle screws, eliminating the need for tapered rods or connectors at the CTJ. Methods: Twenty-six consecutive patients (282 screws) underwent robotic-assisted C-TEK cervical pedicle screw placement crossing the CTJ between April 2024 and June 2025. All procedures utilized the MazorX Stealth Edition robotic system with O-arm intraoperative CT imaging. Two blinded observers assessed screw accuracy using the Gertzbein-Robbins classification. Clinical outcomes and complications were evaluated. Results: Mean age was 54.1 years. In this preliminary series, all 282 screws achieved clinically acceptable placement (grades A–B; 100% in this cohort). Perfect placement (grade A) was achieved in 276 screws (97.9%), with grade B breach in 6 screws (2.1%). No grade C, D, or E breaches occurred. At the cervicothoracic junction levels (C7, T1, T2), 78 screws maintained clinically acceptable accuracy. Interobserver reliability was excellent (κ=0.94). No vertebral artery injuries, permanent neurological deficits, or hardware failures occurred. Illustrative cases demonstrated feasibility across diverse pathologies including dropped head syndrome, dystrophic scoliosis, and revision scenarios. Conclusions: Robotic-assisted C-TEK cervical pedicle screw placement demonstrates high accuracy and technical feasibility for uniform 5.5 mm rod constructs crossing the CTJ without rod diameter transitions or connectors. These preliminary results from a single-center experience support further investigation, including comparative studies with traditional dual-diameter systems. Level of Evidence: Level IV.
- Open Access
- 24 July 2026
- Published by Wolters Kluwer Health in Journal of Craniovertebral Junction and Spine
- Vol. 17 (4) , 361-366
Novel lateral fiducial marker positioning technique eliminates registration failures in high-body mass index patients during robot-assisted spine surgery
Background: Unsuccessful intraoperative computed tomography (CT) registration creates significant technical barriers limiting robot-assisted spine surgery implementation in obese populations due to imaging system field-of-view constraints exceeding patient dimensions. Materials and Methods: This consecutive series evaluated 63 patients with body mass index exceeding 40 kg/m 2 undergoing robot-assisted thoracolumbar fusion between October 2023 and November 2024. A lateral reference marker positioning strategy exploited O-arm’s asymmetric spatial coverage (40 cm transverse vs. 15 cm anteroposterior). Systematic preliminary radiographic assessment guided positioning selection, with lateral placement implemented when scout images demonstrated inadequate fiducial visualization or when patient dimensions approached field-of-view limitations. Results: Lateral positioning was implemented in 17 (27.0%) cases. This approach eliminated severe registration failures, with zero patients requiring more than one reattempt compared to 3 (6.5%) patients in the standard positioning cohort requiring two or more reattempts. Ultimate registration success reached 100% across all cases. First-attempt success was achieved in 82.5% of procedures. Patients requiring reattempts demonstrated significantly prolonged O-arm acquisition intervals (30.3 vs. 19.4 min, P = 0.003) and elevated radiation exposure (61.6 vs. 38.3 mGy, P < 0.001). Optimal pedicle screw positioning (Gertzbein–Robbins Grade A + B) was maintained regardless of technique (lateral 97.6% vs. standard 96.9%, P = 0.650). Conclusion: Lateral reference marker positioning resolves CT registration challenges in obese patients undergoing robot-assisted spine surgery, achieving universal success using existing equipment without additional capital investment.
- 24 July 2026
- Published by Wolters Kluwer Health in Journal of Craniovertebral Junction and Spine
- Vol. 17 (4) , 361-366
Open AccessNovel lateral fiducial marker positioning technique eliminates registration failures in high-body mass index patients during robot-assisted spine surgery
Background: Unsuccessful intraoperative computed tomography (CT) registration creates significant technical barriers limiting robot-assisted spine surgery implementation in obese populations due to imaging system field-of-view constraints exceeding patient dimensions. Materials and Methods: This consecutive series evaluated 63 patients with body mass index exceeding 40 kg/m 2 undergoing robot-assisted thoracolumbar fusion between October 2023 and November 2024. A lateral reference marker positioning strategy exploited O-arm’s asymmetric spatial coverage (40 cm transverse vs. 15 cm anteroposterior). Systematic preliminary radiographic assessment guided positioning selection, with lateral placement implemented when scout images demonstrated inadequate fiducial visualization or when patient dimensions approached field-of-view limitations. Results: Lateral positioning was implemented in 17 (27.0%) cases. This approach eliminated severe registration failures, with zero patients requiring more than one reattempt compared to 3 (6.5%) patients in the standard positioning cohort requiring two or more reattempts. Ultimate registration success reached 100% across all cases. First-attempt success was achieved in 82.5% of procedures. Patients requiring reattempts demonstrated significantly prolonged O-arm acquisition intervals (30.3 vs. 19.4 min, P = 0.003) and elevated radiation exposure (61.6 vs. 38.3 mGy, P < 0.001). Optimal pedicle screw positioning (Gertzbein–Robbins Grade A + B) was maintained regardless of technique (lateral 97.6% vs. standard 96.9%, P = 0.650). Conclusion: Lateral reference marker positioning resolves CT registration challenges in obese patients undergoing robot-assisted spine surgery, achieving universal success using existing equipment without additional capital investment.
- 1 July 2026
- Published by Elsevier in Journal of Orthopaedics
- Vol. 77, 133-141
Balanced Turbo Field Echo MRI as a radiation-free adjunct for spinal bone imaging: A prospective study of 526 patients
- 1 July 2026
- Published by Elsevier in Journal of Orthopaedics
- Vol. 77, 133-141
Balanced Turbo Field Echo MRI as a radiation-free adjunct for spinal bone imaging: A prospective study of 526 patients
- 5 March 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 315
Extended uses of robots in spine surgery beyond thoracolumbar pedicle screws: A narrative review
- 5 March 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 315
Extended uses of robots in spine surgery beyond thoracolumbar pedicle screws: A narrative review
- Open Access
- 28 February 2026
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 20 (1) , 216-218
Response to the letter to the editor: Beyond fixation: computational and motion-integrated perspectives on pinless robot-assisted spine surgery
- 28 February 2026
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 20 (1) , 216-218
Open AccessResponse to the letter to the editor: Beyond fixation: computational and motion-integrated perspectives on pinless robot-assisted spine surgery
- 23 February 2026
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 75, 103396
Impact of robotic assistance on early outcomes in adult spinal deformity surgery: A comparative analysis of inpatient and 30-day outcomes
- 23 February 2026
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 75, 103396
Impact of robotic assistance on early outcomes in adult spinal deformity surgery: A comparative analysis of inpatient and 30-day outcomes
- 13 January 2026
- Published by Elsevier in Journal of Orthopaedics
- Vol. 74, 214-219
Robotic S2Alar iliac screw placement: Comparing conventional and robot assisted minimally invasive techniques
- 13 January 2026
- Published by Elsevier in Journal of Orthopaedics
- Vol. 74, 214-219
Robotic S2Alar iliac screw placement: Comparing conventional and robot assisted minimally invasive techniques
- Open Access
- 1 January 2026
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma and Reconstruction
- Vol. 3 (1) , 77-81
Robotic-assisted Posterior Vertebral Column Resection for Severe Pediatric Thoracolumbar Kyphosis: A Case Report and Review of Literature
A 13-year-old boy with severe thoracolumbar kyphosis (Cobb angle 105°) underwent robotic-assisted posterior vertebral column resection (PVCR) targeting fused T11–T12 vertebrae. Preoperative magnetic resonance imaging showed spinal cord draping over the deformity. The surgical procedure included fusion from T8 to L3, with robotic guidance for pedicle screw placement and vertebral body resection. Postoperative X-rays demonstrated a corrected Cobb angle of 57.2°. We achieved a good correction with less risk due to the accuracy of the robotic system combined with traditional methods, resulting in a good deformity correction in a new and improved, possibly better technique. The patient had a good clinical recovery, walking independently by day 7. This case highlights the efficacy and safety of robotic-assisted PVCR in managing severe paediatric spinal deformities.
- 1 January 2026
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma and Reconstruction
- Vol. 3 (1) , 77-81
Open AccessRobotic-assisted Posterior Vertebral Column Resection for Severe Pediatric Thoracolumbar Kyphosis: A Case Report and Review of Literature
A 13-year-old boy with severe thoracolumbar kyphosis (Cobb angle 105°) underwent robotic-assisted posterior vertebral column resection (PVCR) targeting fused T11–T12 vertebrae. Preoperative magnetic resonance imaging showed spinal cord draping over the deformity. The surgical procedure included fusion from T8 to L3, with robotic guidance for pedicle screw placement and vertebral body resection. Postoperative X-rays demonstrated a corrected Cobb angle of 57.2°. We achieved a good correction with less risk due to the accuracy of the robotic system combined with traditional methods, resulting in a good deformity correction in a new and improved, possibly better technique. The patient had a good clinical recovery, walking independently by day 7. This case highlights the efficacy and safety of robotic-assisted PVCR in managing severe paediatric spinal deformities.