Using artificial neural networks to predict impingement and dislocation in total hip arthroplasty
Authors:
- 4 May 2020
- journal article
- research article
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 23 (10) , 649-657
Abstract
Dislocation after total hip arthroplasty (THA) remains a major issue and an important post-surgical complication. Impingement and subsequent dislocation are influenced by the design (head size) and position (anteversion and abduction angles) of the acetabulum and different movements of the patient, with external extension and internal flexion the most critical movements. The aim of this study is to develop a computational tool based on a three-dimensional (3D) parametric finite element (FE) model and an artificial neural network (ANN) to assist clinicians in identifying the optimal prosthesis design and position of the acetabular cup to reduce the probability of impingement and dislocation. A 3D parametric model of a THA was used. The model parameters were the femoral head size and the acetabulum abduction and anteversion angles. Simulations run with this parametric model were used to train an ANN, which predicts the range of movement (ROM) before impingement and dislocation. This study recreates different configurations and obtains absolute errors lower than 5.5° between the ROM obtained from the FE simulations and the ANN predictions. The ROM is also predicted for patients who had already suffered dislocation after THA, and the computational predictions confirm the patient’s dislocations. Summarising, the combination of a 3D parametric FE model of a THA and an ANN is a useful computational tool to predict the ROM allowed for different designs of prosthesis heads.Keywords
This publication has 38 references indexed in Scilit:
- Exeter Short Stems Compared With Standard Length Exeter StemsThe Journal of Arthroplasty, 2013
- Clinical evaluation of hip joint rotation range of motion in adultsOrthopaedics & Traumatology: Surgery & Research, 2012
- Apparent damage accumulation in cancellous bone using neural networksJournal of the Mechanical Behavior of Biomedical Materials, 2011
- The capsule's contribution to total hip construct stability – A finite element analysisJournal of Orthopaedic Research, 2011
- Influence of Patient-, Design-, and Surgery-Related Factors on Rate of Dislocation After Primary Cementless Total Hip ArthroplastyThe Journal of Arthroplasty, 2009
- (ii) Impingement in total hip replacement: mechanisms and consequencesCurrent Orthopaedics, 2008
- Association between dislocation, impingement, and articular geometry in retrieved acetabular polyethylene cupsJournal of Orthopaedic Research, 2007
- Finite element analysis of shear stresses at the implant-bone interface of an acetabular press-fit cup during impingement / Finite-Elemente-Berechnung der Schubspannungen im Implantat-Knochen-Interface einer acetabulären Press-Fit-Pfanne bei ImpingementBiomedical Engineering / Biomedizinische Technik, 2007
- Influence of Total Hip Design on DislocationClinical Orthopaedics and Related Research, 2006
- Reducing the risk of dislocation after total hip arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2005