An MRI scanner‐independent radiofrequency dosimeter for the estimation of RF power deposition with a human torso phantom
Author:
- 1 February 2017
- journal article
- research article
- Published by Wiley in Concepts in Magnetic Resonance Part B
- Vol. 47B (1)
Abstract
An assessment of radiofrequency (RF) power deposition independent of the information provided by MRI scanners is thus desirable. We developed a novel scanner‐independent RF dosimeter based on measurements of the resistance of a thermistor that dissipates the RF power during scanning. With the RF dosimeter, the RF power deposition for four MRI sequences with specific absorption rate (SAR) values (0.1‐3.3 W/kg) was measured on five different scanners and the correlation between the RF dosimeter reading and the SAR levels calculated by the scanners was investigated. The novel RF dosimeter showed a linear relationship between the RF power deposition and the scanner‐reported whole‐body averaged SAR for each scanner. However, there was a variability in the reading among different scanners. The RF dosimeter readings were 9.7 and 9.5 mW on GE 1.5 T (SAR=2.6 W/kg), 3.6 and 3.7 mW on Philips 1.5 T (SAR=3.3 W/kg), 9.5 and 8.6 mW on Siemens 3 T (SAR=3.0 W/kg), and 4.7 and 3.9 mW on Philips 3 T (SAR=2.6 W/kg), respectively. The scanner‐independent RF dosimeter developed in this study can play a significant role in checking the accuracy of scanners’ SAR values as a standardized method for measuring the RF power deposition for MR safety.Keywords
Funding Information
- National Research Foundation of Korea (NRF-2014R1A1A2054037)
- Korea Research Institute of Standards and Science (KRISS-17011079)
This publication has 24 references indexed in Scilit:
- A multichannel, real‐time MRI RF power monitor for independent SAR determinationMedical Physics, 2012
- System and SAR characterization in parallel RF transmissionMagnetic Resonance in Medicine, 2011
- A prototype RF dosimeter for independent measurement of the average specific absorption rate (SAR) during MRIJournal of Magnetic Resonance Imaging, 2007
- Prediction of specific absorption rate in mother and fetus associated with MRI examinations during pregnancyMagnetic Resonance in Medicine, 2006
- Calculations ofB 1 distribution, specific energy absorption rate, and intrinsic signal-to-noise ratio for a body-size birdcage coil loaded with different human subjects at 64 and 128 MHzApplied Magnetic Resonance, 2005
- Temperature and SAR calculations for a human head within volume and surface coils at 64 and 300 MHzJournal of Magnetic Resonance Imaging, 2004
- Spatial resolution of numerical models of man and calculated specific absorption rate using the FDTD method: A study at 64 MHz in a magnetic resonance imaging coilJournal of Magnetic Resonance Imaging, 2003
- Effects of magnetic resonance imaging on cardiac pacemakers and electrodesAmerican Heart Journal, 1997
- Homogeneous Tissue Model Estimates of RF Power Deposition in Human NMR StudiesAnnals of the New York Academy of Sciences, 1992
- RF magnetic field penetration, phase shift and power dissipation in biological tissue: implications for NMR imagingPhysics in Medicine & Biology, 1978