Tuba Yılmaz Savaş
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tuba Yılmaz Savaş has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Abdulhaluk Savaş
Necmettin Erbakan University, Faculty of Dentistry, Department of Prosthodontics, Konya, Turkey
9 shared publications - Ceyda Akın
Necmettin Erbakan Universitesi
5 shared publications - Bulent Piskin
Associate Professor, Department of Prosthodontics, Gulhane Military Medical Academy, Ankara, Turkey
3 shared publications - Ali Rıza Tunçdemir
Department of Prosthodontics, Faculty of Dentistry, Necmettin Erbakan University, Konya, Turkey
2 shared publications - Alper Uyar
Researcher, Department of Prosthodontics, Gulhane Faculty of Dentistry, Health Sciences University, Ankara, Turkey
2 shared publications - Filiz Aykent
Department of Prosthodontics, Ankara Yıldırım Beyazıt University Faculty of Dentistry, Ankara, Turkey
2 shared publications
Latest Publications
- Open Access
- 24 August 2026
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 13 (2) , 184-190
Effect of Surface Treatments on the Repair Bond Strength Between Aged Glass Ceramics and Composite Resin: An In Vitro Study
Background: This study aimed to investigate the effects of glass bead particle abrasion and different primer systems on the repair bond strength of two types of aged glass ceramics and composite resins. Methods: Eighty specimens were prepared from leucite-reinforced (G-Ceram) and lithium disilicate (IPS e.max CAD) glass-ceramic materials. After thermocycling (5–55 °C, 30 s dwell time, 5000 cycles), each ceramic specimen was divided into five test groups (n=8): control (C), air abrasion with 50-µm glass beads (GB), 37% phosphoric acid etching, Clearfil Ceramic Primer Plus application (CP), Monobond Etch&Prime (MEP) application, 4.8% hydrofluoric acid etching, and Monobond N (MN) application. All specimens were coated with a universal adhesive (Nova Compo B Plus) following treatment. Clearfil Majesty Esthetic, a nanohybrid composite resin, was applied. The specimens were kept in distilled water at 37 °C for 24 h and evaluated for the shear bond strength (1 mm/min). Data were statistically analyzed using two-way ANOVA, Tukey HSD and Bonferroni post-hoc tests (α=0.05).Results: Surface treatment and its interaction with the ceramic material exhibited a statistically significant effect on the repair bond strength (P < 0.05), whereas the main effect of the ceramic type was not significant (P > 0.05). The C and GB groups demonstrated significantly lower mean bond strength values than the CP, MEP, and MN groups (P < 0.05). For the lithium disilicate ceramics, both the CP and MN groups produced the highest bond strengths, with no significant difference between them (P > 0.05). In the leucite-reinforced ceramics, the MN group showed significantly higher bond strength than the CP (P < 0.05). Although the overall effect of surface treatment was consistent across ceramic types, in the CP group, lithium disilicate specimens exhibited a higher bond strength than leucite-reinforced ceramics (P < 0.05).Conclusions: Both phosphoric acid and hydrofluoric acid etching followed by different primer applications achieved the highest bond strength for lithium disilicate ceramics, whereas silane-based treatment after hydrofluoric acid etching was the most effective for leucite-reinforced ceramics. Overall, the tested primers significantly enhanced the bonding to aged glass-ceramics, supporting their use in repair procedures.
- 24 August 2026
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 13 (2) , 184-190
Open AccessEffect of Surface Treatments on the Repair Bond Strength Between Aged Glass Ceramics and Composite Resin: An In Vitro Study
Background: This study aimed to investigate the effects of glass bead particle abrasion and different primer systems on the repair bond strength of two types of aged glass ceramics and composite resins. Methods: Eighty specimens were prepared from leucite-reinforced (G-Ceram) and lithium disilicate (IPS e.max CAD) glass-ceramic materials. After thermocycling (5–55 °C, 30 s dwell time, 5000 cycles), each ceramic specimen was divided into five test groups (n=8): control (C), air abrasion with 50-µm glass beads (GB), 37% phosphoric acid etching, Clearfil Ceramic Primer Plus application (CP), Monobond Etch&Prime (MEP) application, 4.8% hydrofluoric acid etching, and Monobond N (MN) application. All specimens were coated with a universal adhesive (Nova Compo B Plus) following treatment. Clearfil Majesty Esthetic, a nanohybrid composite resin, was applied. The specimens were kept in distilled water at 37 °C for 24 h and evaluated for the shear bond strength (1 mm/min). Data were statistically analyzed using two-way ANOVA, Tukey HSD and Bonferroni post-hoc tests (α=0.05).Results: Surface treatment and its interaction with the ceramic material exhibited a statistically significant effect on the repair bond strength (P < 0.05), whereas the main effect of the ceramic type was not significant (P > 0.05). The C and GB groups demonstrated significantly lower mean bond strength values than the CP, MEP, and MN groups (P < 0.05). For the lithium disilicate ceramics, both the CP and MN groups produced the highest bond strengths, with no significant difference between them (P > 0.05). In the leucite-reinforced ceramics, the MN group showed significantly higher bond strength than the CP (P < 0.05). Although the overall effect of surface treatment was consistent across ceramic types, in the CP group, lithium disilicate specimens exhibited a higher bond strength than leucite-reinforced ceramics (P < 0.05).Conclusions: Both phosphoric acid and hydrofluoric acid etching followed by different primer applications achieved the highest bond strength for lithium disilicate ceramics, whereas silane-based treatment after hydrofluoric acid etching was the most effective for leucite-reinforced ceramics. Overall, the tested primers significantly enhanced the bonding to aged glass-ceramics, supporting their use in repair procedures.
- 18 April 2025
- Published by Academician Publishing
- p. 73-92
Bruksizm: Etyoloji, Tanı, Protetik ve Multidisipliner Tedavi Stratejileri
Bruksizm, diş sıkma ve gıcırdatma ile karakterize edilen, multifaktöriyel etiyolojiye sahip parafonksiyonel bir alışkanlıktır. Uyku ve uyanık bruksizmi olarak ikiye ayrılan bu durum, bireyin oral ve sistemik sağlığını olumsuz etkileyebilir. Bruksizmin etiyolojisinde stres, anksiyete, uyku bozuklukları, nörolojik faktörler ve bazı ilaçların etkili olduğu düşünülmektedir. Tanı genellikle hasta anamnezi, klinik muayene ve polisomnografi gibi yöntemlerle konulmaktadır. Tedavi yaklaşımları arasında oklüzal splintler, fizyoterapi, davranışsal terapi ve farmakolojik ajanlar yer almaktadır. Ayrıca, implant destekli ve sabit protez uygulamalarında bruksizmin etkileri dikkate alınmalı, restorasyon planlamasında özel önlemler alınmalıdır. Bruksizmin yönetiminde multidisipliner yaklaşım önemlidir ve bireyselleştirilmiş tedavi planlarının uygulanması gerekmektedir. Bu bölümde, bruksizmin etiyolojisi, klinik belirtileri, tanı yöntemleri ve protetik yaklaşımlar değerlendirilmektedir. Bruxism is a parafunctional habit characterized by teeth grinding and clenching, with a multifactorial etiology. It is classified into sleep and awake bruxism, both of which can negatively affect oral and systemic health. The etiology of bruxism includes stress, anxiety, sleep disorders, neurological factors, and certain medications. Diagnosis is commonly made through patient history, clinical examination, and polysomnography. Treatment approaches include occlusal splints, physiotherapy, behavioral therapy, and pharmacological agents. Additionally, the effects of bruxism should be considered in implant-supported and fixed prosthetic restorations, with special precautions taken in treatment planning. A multidisciplinary approach is essential in managing bruxism, emphasizing individualized treatment plans. This section discusses the etiology, clinical symptoms, diagnostic methods, and prosthetic management of bruxism.
- 18 April 2025
- Published by Academician Publishing
- p. 73-92
Bruksizm: Etyoloji, Tanı, Protetik ve Multidisipliner Tedavi Stratejileri
Bruksizm, diş sıkma ve gıcırdatma ile karakterize edilen, multifaktöriyel etiyolojiye sahip parafonksiyonel bir alışkanlıktır. Uyku ve uyanık bruksizmi olarak ikiye ayrılan bu durum, bireyin oral ve sistemik sağlığını olumsuz etkileyebilir. Bruksizmin etiyolojisinde stres, anksiyete, uyku bozuklukları, nörolojik faktörler ve bazı ilaçların etkili olduğu düşünülmektedir. Tanı genellikle hasta anamnezi, klinik muayene ve polisomnografi gibi yöntemlerle konulmaktadır. Tedavi yaklaşımları arasında oklüzal splintler, fizyoterapi, davranışsal terapi ve farmakolojik ajanlar yer almaktadır. Ayrıca, implant destekli ve sabit protez uygulamalarında bruksizmin etkileri dikkate alınmalı, restorasyon planlamasında özel önlemler alınmalıdır. Bruksizmin yönetiminde multidisipliner yaklaşım önemlidir ve bireyselleştirilmiş tedavi planlarının uygulanması gerekmektedir. Bu bölümde, bruksizmin etiyolojisi, klinik belirtileri, tanı yöntemleri ve protetik yaklaşımlar değerlendirilmektedir. Bruxism is a parafunctional habit characterized by teeth grinding and clenching, with a multifactorial etiology. It is classified into sleep and awake bruxism, both of which can negatively affect oral and systemic health. The etiology of bruxism includes stress, anxiety, sleep disorders, neurological factors, and certain medications. Diagnosis is commonly made through patient history, clinical examination, and polysomnography. Treatment approaches include occlusal splints, physiotherapy, behavioral therapy, and pharmacological agents. Additionally, the effects of bruxism should be considered in implant-supported and fixed prosthetic restorations, with special precautions taken in treatment planning. A multidisciplinary approach is essential in managing bruxism, emphasizing individualized treatment plans. This section discusses the etiology, clinical symptoms, diagnostic methods, and prosthetic management of bruxism.
- 18 April 2025
- Published by Academician Publishing
- p. 93-108
Geriatrik Hastalarda Protez Uygulamaları
Geriatrik bireylerde yaşlanma süreci, fizyolojik değişikliklerle birlikte ağız sağlığı üzerinde önemli etkiler yaratmaktadır. Diş kaybı ve protez ihtiyacı yaşlı bireylerde yaygın olmakla birlikte, uygun protez uygulamaları çiğneme fonksiyonunu ve genel yaşam kalitesini iyileştirebilmektedir. Ancak, geriatrik hastalarda protez kullanımıyla ilişkili zorluklar arasında ağız hijyeninin yetersizliği, protez stomatiti ve bilişsel bozuklukların etkisi yer almaktadır. Protez uygulamalarında hasta memnuniyetini artırmak için bireyselleştirilmiş tedavi planları ve multidisipliner yaklaşımlar gereklidir. İmplant destekli protezler, geleneksel hareketli protezlere kıyasla daha iyi fonksiyonel ve estetik sonuçlar sunabilmektedir. Ayrıca, sosyoekonomik faktörler, dental bakım hizmetlerine erişimi etkileyerek geriatrik bireylerde protez kullanımını doğrudan etkilemektedir. Bu bölümde, yaşlı bireylerde protez uygulamalarının önemi, karşılaşılan zorluklar ve olası çözümler ele alınmaktadır. Geriatrik hastaların yaşam kalitesini artırmak amacıyla düzenli kontroller, hijyen eğitimi ve gelişmiş protetik çözümler önerilmektedir. The aging process in geriatric individuals leads to physiological changes that significantly impact oral health. Tooth loss and the need for prostheses are common among older adults, and appropriate prosthetic applications can improve masticatory function and overall quality of life. However, challenges related to prosthesis use in geriatric patients include inadequate oral hygiene, denture stomatitis, and cognitive impairments. Personalized treatment plans and multidisciplinary approaches are essential for enhancing patient satisfaction with prosthetic applications. Implant-supported prostheses offer superior functional and aesthetic outcomes compared to conventional removable dentures. Moreover, socioeconomic factors influence access to dental care services, directly affecting prosthesis use among elderly individuals. This section explores the significance of prosthetic applications in elderly patients, associated challenges, and potential solutions. Regular follow-ups, hygiene education, and advanced prosthetic solutions are recommended to enhance the quality of life in geriatric patients.
- 18 April 2025
- Published by Academician Publishing
- p. 93-108
Geriatrik Hastalarda Protez Uygulamaları
Geriatrik bireylerde yaşlanma süreci, fizyolojik değişikliklerle birlikte ağız sağlığı üzerinde önemli etkiler yaratmaktadır. Diş kaybı ve protez ihtiyacı yaşlı bireylerde yaygın olmakla birlikte, uygun protez uygulamaları çiğneme fonksiyonunu ve genel yaşam kalitesini iyileştirebilmektedir. Ancak, geriatrik hastalarda protez kullanımıyla ilişkili zorluklar arasında ağız hijyeninin yetersizliği, protez stomatiti ve bilişsel bozuklukların etkisi yer almaktadır. Protez uygulamalarında hasta memnuniyetini artırmak için bireyselleştirilmiş tedavi planları ve multidisipliner yaklaşımlar gereklidir. İmplant destekli protezler, geleneksel hareketli protezlere kıyasla daha iyi fonksiyonel ve estetik sonuçlar sunabilmektedir. Ayrıca, sosyoekonomik faktörler, dental bakım hizmetlerine erişimi etkileyerek geriatrik bireylerde protez kullanımını doğrudan etkilemektedir. Bu bölümde, yaşlı bireylerde protez uygulamalarının önemi, karşılaşılan zorluklar ve olası çözümler ele alınmaktadır. Geriatrik hastaların yaşam kalitesini artırmak amacıyla düzenli kontroller, hijyen eğitimi ve gelişmiş protetik çözümler önerilmektedir. The aging process in geriatric individuals leads to physiological changes that significantly impact oral health. Tooth loss and the need for prostheses are common among older adults, and appropriate prosthetic applications can improve masticatory function and overall quality of life. However, challenges related to prosthesis use in geriatric patients include inadequate oral hygiene, denture stomatitis, and cognitive impairments. Personalized treatment plans and multidisciplinary approaches are essential for enhancing patient satisfaction with prosthetic applications. Implant-supported prostheses offer superior functional and aesthetic outcomes compared to conventional removable dentures. Moreover, socioeconomic factors influence access to dental care services, directly affecting prosthesis use among elderly individuals. This section explores the significance of prosthetic applications in elderly patients, associated challenges, and potential solutions. Regular follow-ups, hygiene education, and advanced prosthetic solutions are recommended to enhance the quality of life in geriatric patients.
- Open Access
- 18 April 2025
- Published by Academician Publishing
Güncel Protetik Diş Tedavisi Çalışmaları VIII (Bahar)
Dijital Ölçü Teknolojileri ve Tarayıcıların Veri Toplama Prensipleri Mehmet KARAKUZU Caner ÖZTÜRK Üç Boyutlu Eklemeli İmalat ile Üretilen Seramik Restorasyonlar Taha Yaşar MANAV Beyza Nur TERLER NALBAT Dijital Üretim İş Akışında Endokronlar Elifnur GÜZELCE SULTANOĞLU Protetik Diş Tedavisinde Yapay Zeka: Güncel Uygulamalar ve Gelecek Perspektifleri Zeynep YEŞİL Gizem YILMAZ Bruksizm: Etyoloji, Tanı, Protetik ve Multidisipliner Tedavi Stratejileri Abdulhaluk SAVAŞ Tuba YILMAZ SAVAŞ Geriatrik Hastalarda Protez Uygulamaları Tuba YILMAZ SAVAŞ Abdulhaluk SAVAŞ Protetik Diş Tedavisinde Eklemeli Üretim: Klinik Kullanım ve Kronolojik Gelişim Rabia ÇİÇEK İpek ÇAĞLAR Laminate Veneerler ve Renk Başarısını Etkileyen Faktörler Kardelen GÜREL Gaye SAĞLAM Şükriye Ece GEDUK Polietereterketonun Yapısı, Özellikleri ve Diş Hekimliğinde Kullanımı Mustafa AYATA Ravza ERASLAN Dişeti Retraksiyonu: Mekanik, Cerrahi, Kemomekanik ve Güncel Yaklaşımlar Mustafa AYATA Ravza ERASLAN
- 18 April 2025
- Published by Academician Publishing
Open AccessGüncel Protetik Diş Tedavisi Çalışmaları VIII (Bahar)
Dijital Ölçü Teknolojileri ve Tarayıcıların Veri Toplama Prensipleri Mehmet KARAKUZU Caner ÖZTÜRK Üç Boyutlu Eklemeli İmalat ile Üretilen Seramik Restorasyonlar Taha Yaşar MANAV Beyza Nur TERLER NALBAT Dijital Üretim İş Akışında Endokronlar Elifnur GÜZELCE SULTANOĞLU Protetik Diş Tedavisinde Yapay Zeka: Güncel Uygulamalar ve Gelecek Perspektifleri Zeynep YEŞİL Gizem YILMAZ Bruksizm: Etyoloji, Tanı, Protetik ve Multidisipliner Tedavi Stratejileri Abdulhaluk SAVAŞ Tuba YILMAZ SAVAŞ Geriatrik Hastalarda Protez Uygulamaları Tuba YILMAZ SAVAŞ Abdulhaluk SAVAŞ Protetik Diş Tedavisinde Eklemeli Üretim: Klinik Kullanım ve Kronolojik Gelişim Rabia ÇİÇEK İpek ÇAĞLAR Laminate Veneerler ve Renk Başarısını Etkileyen Faktörler Kardelen GÜREL Gaye SAĞLAM Şükriye Ece GEDUK Polietereterketonun Yapısı, Özellikleri ve Diş Hekimliğinde Kullanımı Mustafa AYATA Ravza ERASLAN Dişeti Retraksiyonu: Mekanik, Cerrahi, Kemomekanik ve Güncel Yaklaşımlar Mustafa AYATA Ravza ERASLAN
- Open Access
- 30 December 2023
- Published by Cappadocia University in Kapadokya Üniversitesi
- Vol. 3 (2) , 62-75
Influence of Composition and Thickness on The Color and Translucency of Glass-Ceramic Materials for Laminate Veneer Restorations: An In Vitro study
Statement of the problem: Numerous glass-ceramic materials are commercially available, yet achieving optimal esthetic results relies significantly on material composition and thickness. The selection of suitable material and thickness poses an ongoing challenge in clinical practice. Objective: This study aimed to investigate the effect of the composition and thickness of different glass-ceramic materials on the Commission Internationale de l'éclairage (CIE) L*, a*, and b* color coordinates and the translucency parameter (TP00). Materials & Methods: Glass-ceramic blocks of A2 shade, with low translucency, encompassing feldspathic (FS), leucite-reinforced feldspathic (LR), and lithium-disilicate (LD) compositions, were sectioned into three thicknesses: 0.5 mm, 0.7 mm, and 1 mm (n=10). All specimens were polished with ceramic polishing rubbers. Using a spectrophotometer, the CIE L*, a*, and b* color coordinates of the specimens were measured over gray, white, and black backgrounds. The TP00 was calculated using the CIEDE2000 color difference formula. The CIE L*, a*, b*, and TP00 were analyzed using two-way ANOVA and Tukey HSD post-hoc tests (α=0.05). Results: Material, thickness, and their interaction significantly influenced the CIE L*, a*, b*, and TP00 values (P0.05). Conclusions: Even when sharing the same shade, glass ceramics may exhibit varying color and translucency properties due to their distinct chemical compositions and thicknesses.
- 30 December 2023
- Published by Cappadocia University in Kapadokya Üniversitesi
- Vol. 3 (2) , 62-75
Open AccessInfluence of Composition and Thickness on The Color and Translucency of Glass-Ceramic Materials for Laminate Veneer Restorations: An In Vitro study
Statement of the problem: Numerous glass-ceramic materials are commercially available, yet achieving optimal esthetic results relies significantly on material composition and thickness. The selection of suitable material and thickness poses an ongoing challenge in clinical practice. Objective: This study aimed to investigate the effect of the composition and thickness of different glass-ceramic materials on the Commission Internationale de l'éclairage (CIE) L*, a*, and b* color coordinates and the translucency parameter (TP00). Materials & Methods: Glass-ceramic blocks of A2 shade, with low translucency, encompassing feldspathic (FS), leucite-reinforced feldspathic (LR), and lithium-disilicate (LD) compositions, were sectioned into three thicknesses: 0.5 mm, 0.7 mm, and 1 mm (n=10). All specimens were polished with ceramic polishing rubbers. Using a spectrophotometer, the CIE L*, a*, and b* color coordinates of the specimens were measured over gray, white, and black backgrounds. The TP00 was calculated using the CIEDE2000 color difference formula. The CIE L*, a*, b*, and TP00 were analyzed using two-way ANOVA and Tukey HSD post-hoc tests (α=0.05). Results: Material, thickness, and their interaction significantly influenced the CIE L*, a*, b*, and TP00 values (P0.05). Conclusions: Even when sharing the same shade, glass ceramics may exhibit varying color and translucency properties due to their distinct chemical compositions and thicknesses.
- Open Access
- 30 December 2023
- Published by Cappadocia University in Kapadokya Üniversitesi
- Vol. 3 (2) , 86-98
Effects of Different Chemical Disinfectants on Physical Properties of Denture Base Acrylic Resin Material
Statement of the problem: There is still a lack of data regarding the effects of exposure to different chemical disinfectants on the color stability, light translucency, and surface roughness of dentures is limited. Objective: This study aims to investigate the impact of six different chemical disinfectants on the color change, translucency, and surface roughness properties of heat-polymerized denture base acrylic resin. Material & Methods: Totally 70 rectangular blocks (10×10×2 mm) were polymerized from the heat-polymerized acrylic denture base resin material. The surfaces of the specimens polished with 600- and 1200-grit waterproof abrasive paper. Each specimen were immersed in six denture cleansers. The total immersion time of a specimen in selected chemical disinfectant was 36 hours. Color changes, translucency and, surface roughness were measured after immersion process. The results were statistically analyzed with 1-way ANOVA and the Tukey honestly significant difference (HSD) test (α=.05). Results: According to the results of the 1-way ANOVA test, significant differences were observed in the ∆E00, TP00 and Ra properties among the acrylic resin groups following immersion in chemical disinfectants (P<0.05). ΔE00 value of the CG group was significantly higher than that of the NS, SH, G, and E groups (P<0.05). The TP00 values of the NS and G groups were demonstrated significant differences compared with C group (P<0.05). The Ra values of the SH, SP, G, CG and, E groups were significantly increased after immersion process, in comparison with C and NS groups (P<0.05). Conclusions: Color stability, translucency and surface roughness of the denture base heat polymerized acrylic resin is influenced by chemical disinfectants.
- 30 December 2023
- Published by Cappadocia University in Kapadokya Üniversitesi
- Vol. 3 (2) , 86-98
Open AccessEffects of Different Chemical Disinfectants on Physical Properties of Denture Base Acrylic Resin Material
Statement of the problem: There is still a lack of data regarding the effects of exposure to different chemical disinfectants on the color stability, light translucency, and surface roughness of dentures is limited. Objective: This study aims to investigate the impact of six different chemical disinfectants on the color change, translucency, and surface roughness properties of heat-polymerized denture base acrylic resin. Material & Methods: Totally 70 rectangular blocks (10×10×2 mm) were polymerized from the heat-polymerized acrylic denture base resin material. The surfaces of the specimens polished with 600- and 1200-grit waterproof abrasive paper. Each specimen were immersed in six denture cleansers. The total immersion time of a specimen in selected chemical disinfectant was 36 hours. Color changes, translucency and, surface roughness were measured after immersion process. The results were statistically analyzed with 1-way ANOVA and the Tukey honestly significant difference (HSD) test (α=.05). Results: According to the results of the 1-way ANOVA test, significant differences were observed in the ∆E00, TP00 and Ra properties among the acrylic resin groups following immersion in chemical disinfectants (P<0.05). ΔE00 value of the CG group was significantly higher than that of the NS, SH, G, and E groups (P<0.05). The TP00 values of the NS and G groups were demonstrated significant differences compared with C group (P<0.05). The Ra values of the SH, SP, G, CG and, E groups were significantly increased after immersion process, in comparison with C and NS groups (P<0.05). Conclusions: Color stability, translucency and surface roughness of the denture base heat polymerized acrylic resin is influenced by chemical disinfectants.
- Open Access
- 6 July 2023
- Published by Wiley in Journal of Prosthodontics
- Vol. 33 (2) , 123-131
Comparison of efficacy and usability of custom mandibular advancement devices fabricated with the conventional method and digital workflow: A pilot clinical study
Purpose: To compare the effects of fabricating methods of custom monoblock mandibular advancement devices (MADs) on usability and efficacy in patients with mild and moderate obstructive sleep apnea (OSA).Materials and Methods: Digitally fabricated custom MADs (dMADs) were produced for 11 OSA participants who had previously used conventionally fabricated custom MADs (cMADs). The participants answered a modified usability questionnaire for both MADs, and the average scores that were given to the questionnaire were evaluated by age, sex, and body mass index (BMI), and the scores of cMADs and dMADs were compared. After 6 months of usage of each MAD, the apnea‐hypopnea index (AHI), mean and lowest oxygen saturations, and total sleep time were measured for efficacy assessment. Data were analyzed with Cronbach's alpha, Mann‐Whitney U, Kruskal‐Wallis, Wilcoxon signed‐rank, one‐way repeated measures analyses of variance, and Bonferroni tests (α = 0.05).Results: Cronbach's alpha was found at 0.834 and 0.722 for the conventional and digital questionnaires, respectively. The usability scores of the dMADs were significantly higher than those of cMADs (p = 0.013). There was no difference in usability scores in terms of sex or BMI (p > 0.05). No statistically significant difference was found for cMAD (p = 0.113) among age groups; however, there was a significant difference for dMAD (p = 0.046). The AHI, mean, and lowest oxygen saturation values were significantly affected by MAD usage (p < 0.001). However, total sleep time values did not differ after the MAD treatments (p > 0.05). Significantly lower AHI and significantly higher lowest oxygen saturation values were observed with dMAD, while both appliances led to similar results for mean oxygen saturation and total sleep time values (p > 0.05).Conclusions: Participant usability scores were higher for digitally manufactured MADs than conventionally manufactured MADs. However, both conventional and digital MADs were found effective in decreasing the AHI levels and increasing the mean and lowest oxygen saturation values of the participants.
- 6 July 2023
- Published by Wiley in Journal of Prosthodontics
- Vol. 33 (2) , 123-131
Open AccessComparison of efficacy and usability of custom mandibular advancement devices fabricated with the conventional method and digital workflow: A pilot clinical study
Purpose: To compare the effects of fabricating methods of custom monoblock mandibular advancement devices (MADs) on usability and efficacy in patients with mild and moderate obstructive sleep apnea (OSA).Materials and Methods: Digitally fabricated custom MADs (dMADs) were produced for 11 OSA participants who had previously used conventionally fabricated custom MADs (cMADs). The participants answered a modified usability questionnaire for both MADs, and the average scores that were given to the questionnaire were evaluated by age, sex, and body mass index (BMI), and the scores of cMADs and dMADs were compared. After 6 months of usage of each MAD, the apnea‐hypopnea index (AHI), mean and lowest oxygen saturations, and total sleep time were measured for efficacy assessment. Data were analyzed with Cronbach's alpha, Mann‐Whitney U, Kruskal‐Wallis, Wilcoxon signed‐rank, one‐way repeated measures analyses of variance, and Bonferroni tests (α = 0.05).Results: Cronbach's alpha was found at 0.834 and 0.722 for the conventional and digital questionnaires, respectively. The usability scores of the dMADs were significantly higher than those of cMADs (p = 0.013). There was no difference in usability scores in terms of sex or BMI (p > 0.05). No statistically significant difference was found for cMAD (p = 0.113) among age groups; however, there was a significant difference for dMAD (p = 0.046). The AHI, mean, and lowest oxygen saturation values were significantly affected by MAD usage (p < 0.001). However, total sleep time values did not differ after the MAD treatments (p > 0.05). Significantly lower AHI and significantly higher lowest oxygen saturation values were observed with dMAD, while both appliances led to similar results for mean oxygen saturation and total sleep time values (p > 0.05).Conclusions: Participant usability scores were higher for digitally manufactured MADs than conventionally manufactured MADs. However, both conventional and digital MADs were found effective in decreasing the AHI levels and increasing the mean and lowest oxygen saturation values of the participants.
- 26 June 2023
- Published by Cappadocia University in Kapadokya Üniversitesi
Influence of Different Surface Conditioning Methods on Adhesion of Resin Cement to Zirconia
Statement of the problem: The challenge of enhancing the bond between zirconia and resin remains, and the efforts continue to determine a simple method for achieving a durable bond. Objective: This study aimed to evaluate the effect of different surface conditioning strategies on the bond strength between zirconia and resin ce-ment. Materials & Methods: Forty zirconia specimens (Lava Plus) were fabricated and divided into four groups: control (no surface treatment), pri-mer application (Z-Prime Plus), experimental acid (H2O:HF:H2O2) applica-tion, and the combination of the acid and primer application (n=10). A dual-cure resin cement (RelyX Ultimate) was applied over the zirconia specimens. Shear bond strength tests were conducted using a universal testing machine with a cross-head speed of 1 mm/min. The results were analyzed using one-way ANOVA followed by Tukey's post hoc test within the 95% confidence interval. Results: The results of the one-way ANOVA showed that acid appli-cation alone (22.99 ± 2.49 MPa) and acid and primer application (25.24 ± 3.19 MPa) had significantly higher bond strength than the primer (18.87 ± 3.13 MPa) and control (14.91 ± 3.72 MPa) groups (P<0.05). However, there was no significant difference between the acid group and acid and primer combination group (P=0.396). The control group had the lowest bond strength in all test groups (P<0.05). Conclusions: Experimental acid treatment alone or in combination with primer application could be effective in improving the bond strength.
- 26 June 2023
- Published by Cappadocia University in Kapadokya Üniversitesi
Influence of Different Surface Conditioning Methods on Adhesion of Resin Cement to Zirconia
Statement of the problem: The challenge of enhancing the bond between zirconia and resin remains, and the efforts continue to determine a simple method for achieving a durable bond. Objective: This study aimed to evaluate the effect of different surface conditioning strategies on the bond strength between zirconia and resin ce-ment. Materials & Methods: Forty zirconia specimens (Lava Plus) were fabricated and divided into four groups: control (no surface treatment), pri-mer application (Z-Prime Plus), experimental acid (H2O:HF:H2O2) applica-tion, and the combination of the acid and primer application (n=10). A dual-cure resin cement (RelyX Ultimate) was applied over the zirconia specimens. Shear bond strength tests were conducted using a universal testing machine with a cross-head speed of 1 mm/min. The results were analyzed using one-way ANOVA followed by Tukey's post hoc test within the 95% confidence interval. Results: The results of the one-way ANOVA showed that acid appli-cation alone (22.99 ± 2.49 MPa) and acid and primer application (25.24 ± 3.19 MPa) had significantly higher bond strength than the primer (18.87 ± 3.13 MPa) and control (14.91 ± 3.72 MPa) groups (P<0.05). However, there was no significant difference between the acid group and acid and primer combination group (P=0.396). The control group had the lowest bond strength in all test groups (P<0.05). Conclusions: Experimental acid treatment alone or in combination with primer application could be effective in improving the bond strength.
- Open Access
- 26 June 2023
- Published by Cappadocia University in Kapadokya Üniversitesi
Does the Duration of Acid Treatment Affect the Bond Strength Between Resin Cement and Zirconia
Statement of the problem: The bonding between the resin cement and zirconia still needs to be improved and the effect of the experimental acid application duration on the resin bond strength with zirconia is unk-nown. Objective: This study aimed to investigate the effect of different acid application times on the shear bond strength between zirconia and dual-cure resin cement. Materials & Methods: A total of 50 zirconia disks were prepared in 2 mm thickness and randomly divided into five treatment groups: control (no treatment was applied), 30 seconds HF:H2O:H2O2 acid application group, 60 seconds HF:H2O:H2O2 acid application group, 90 seconds HF:H2O:H2O2 acid application group, and 120 seconds HF:H2O:H2O2 acid application group. Then a dual-cure resin cement was applied over the 3 mm diameter and 3 mm thickness of the zirconia specimens. The speci-mens were immersed in distilled water and maintained at a temperature of 37°C for a duration of 24 hours. The shear bond strength tests were perfor-med using a universal testing machine with a force of 1 mm/min until the fracture occurs, and the data were analyzed using one-way ANOVA and Tukey's post-hoc test. Results: The highest mean shear bond strength was found in the 90 seconds acid application group, which was significantly higher than the control and 30 seconds acid application groups (P0.05). Conclusions: The use of a 60-, 90- and 120 seconds acid application can improve the bond strength between zirconia and resin cement. However, caution should be taken when using this acid due to its potential toxicity and hazards.
- 26 June 2023
- Published by Cappadocia University in Kapadokya Üniversitesi
Open AccessDoes the Duration of Acid Treatment Affect the Bond Strength Between Resin Cement and Zirconia
Statement of the problem: The bonding between the resin cement and zirconia still needs to be improved and the effect of the experimental acid application duration on the resin bond strength with zirconia is unk-nown. Objective: This study aimed to investigate the effect of different acid application times on the shear bond strength between zirconia and dual-cure resin cement. Materials & Methods: A total of 50 zirconia disks were prepared in 2 mm thickness and randomly divided into five treatment groups: control (no treatment was applied), 30 seconds HF:H2O:H2O2 acid application group, 60 seconds HF:H2O:H2O2 acid application group, 90 seconds HF:H2O:H2O2 acid application group, and 120 seconds HF:H2O:H2O2 acid application group. Then a dual-cure resin cement was applied over the 3 mm diameter and 3 mm thickness of the zirconia specimens. The speci-mens were immersed in distilled water and maintained at a temperature of 37°C for a duration of 24 hours. The shear bond strength tests were perfor-med using a universal testing machine with a force of 1 mm/min until the fracture occurs, and the data were analyzed using one-way ANOVA and Tukey's post-hoc test. Results: The highest mean shear bond strength was found in the 90 seconds acid application group, which was significantly higher than the control and 30 seconds acid application groups (P0.05). Conclusions: The use of a 60-, 90- and 120 seconds acid application can improve the bond strength between zirconia and resin cement. However, caution should be taken when using this acid due to its potential toxicity and hazards.
- Open Access
- 15 June 2023
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 10 (4) , 144-148
Farklı kalınlıklardaki CAD-CAM materyallerinin opalesans ve kontrast oranlarının karşılaştırılması
Amaç: Bu in vitro çalışmanın amacı, farklı kimyasal kompozisyona sahip çeşitli kalınlıklardaki üç farklı CAD-CAM materyalinin opalaseans parametresi (OP) ve kontrast oranının (CR) karşılaştırılmasıdır. Gereç ve Yöntem: Doksan adet A2 renkte örnek; lösitle güçlendirilmiş feldspatik seramik (LS, G-Ceram), lityum disilikat seramik (LD, IPS e.max CAD) ve rezin nano seramik (RN, Lava Ultimate) CAD-CAM bloklardan 0,5 mm, 0,7 mm ve 1 mm kalınlığında olacak şekilde hazırlandı (n=10). Renk ölçümleri siyah ve beyaz arka planlar üzerinde bir spektrofotometre ile gerçekleştirilerek CIE L*a*b* verileri kaydedildi. Örneklerin OP ve CR değerleri hesaplandı. İstatistiksel analiz iki yönlü ANOVA ve Bonferroni testleri ile yapıldı (α=0,05). Bulgular: Materyal ve kalınlık temel etkisi ile materyal ve kalınlık etkileşimi OP ve CR için önemli bulundu (P<0,001). OP değeri üzerinde materyal tipinin etkisi kalınlık etkisinden daha yüksek olurken (ηp2=0,973), CR değeri üzerinde kalınlığın etkisi (ηp2=0,879) daha fazla bulundu. En yüksek ortalama OP değeri RN grubunda, en düşük ortalama OP değeri ise LS grubunda elde edildi (P<0,001). Kalınlığı 0,7 mm ve 1 mm olan örnekler benzer OP değerleri sergilerken, 0,5 mm kalınlığındaki örnekler istatistiksel olarak daha düşük OP değeri gösterdi (P0,05) ancak LS grubu daha yüksek ortalama CR değeri gösterdi (P<0,001). Her üç materyal 1 mm kalınlığında benzer CR değerleri sergilese de 0,5 mm ve 0,7 mm kalınlığındaki LD ve RN grupları LS grubuna kıyasla daha düşük CR değerleri gösterdi (P<0,05). Sonuç: Materyal tipi ve kalınlığı OP ve CR değerlerini etkilemiştir. Kalınlık arttıkça CR azalmakta ancak OP artmaktadır. Kalınlık CR parametresini materyal tipine kıyasla daha çok etkilemiştir. Materyal tipi ise opalesans parametresini kalınlığa kıyasla daha çok etkilemiştir.
- 15 June 2023
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 10 (4) , 144-148
Open AccessFarklı kalınlıklardaki CAD-CAM materyallerinin opalesans ve kontrast oranlarının karşılaştırılması
Amaç: Bu in vitro çalışmanın amacı, farklı kimyasal kompozisyona sahip çeşitli kalınlıklardaki üç farklı CAD-CAM materyalinin opalaseans parametresi (OP) ve kontrast oranının (CR) karşılaştırılmasıdır. Gereç ve Yöntem: Doksan adet A2 renkte örnek; lösitle güçlendirilmiş feldspatik seramik (LS, G-Ceram), lityum disilikat seramik (LD, IPS e.max CAD) ve rezin nano seramik (RN, Lava Ultimate) CAD-CAM bloklardan 0,5 mm, 0,7 mm ve 1 mm kalınlığında olacak şekilde hazırlandı (n=10). Renk ölçümleri siyah ve beyaz arka planlar üzerinde bir spektrofotometre ile gerçekleştirilerek CIE L*a*b* verileri kaydedildi. Örneklerin OP ve CR değerleri hesaplandı. İstatistiksel analiz iki yönlü ANOVA ve Bonferroni testleri ile yapıldı (α=0,05). Bulgular: Materyal ve kalınlık temel etkisi ile materyal ve kalınlık etkileşimi OP ve CR için önemli bulundu (P<0,001). OP değeri üzerinde materyal tipinin etkisi kalınlık etkisinden daha yüksek olurken (ηp2=0,973), CR değeri üzerinde kalınlığın etkisi (ηp2=0,879) daha fazla bulundu. En yüksek ortalama OP değeri RN grubunda, en düşük ortalama OP değeri ise LS grubunda elde edildi (P<0,001). Kalınlığı 0,7 mm ve 1 mm olan örnekler benzer OP değerleri sergilerken, 0,5 mm kalınlığındaki örnekler istatistiksel olarak daha düşük OP değeri gösterdi (P0,05) ancak LS grubu daha yüksek ortalama CR değeri gösterdi (P<0,001). Her üç materyal 1 mm kalınlığında benzer CR değerleri sergilese de 0,5 mm ve 0,7 mm kalınlığındaki LD ve RN grupları LS grubuna kıyasla daha düşük CR değerleri gösterdi (P<0,05). Sonuç: Materyal tipi ve kalınlığı OP ve CR değerlerini etkilemiştir. Kalınlık arttıkça CR azalmakta ancak OP artmaktadır. Kalınlık CR parametresini materyal tipine kıyasla daha çok etkilemiştir. Materyal tipi ise opalesans parametresini kalınlığa kıyasla daha çok etkilemiştir.