Paul Nardelli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Paul Nardelli has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Timothy Charles Cope
Coulter Department of Biomedical Engineering Emory University and Georgia Institute of Technology Atlanta Georgia USA
3 shared publications - Amro Alshareef
Georgia Institute of Technology 1 Woodruff School of Mechanical Engineering Atlanta, GA 30332
2 shared publications - Gregory S. Sawicki
School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
2 shared publications - Lena H. Ting
Wallace H. Coulter Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, GA, USA
2 shared publications Giulia A. Vitali
School of Biological Sciences, Georgia Institute of Technology, Atlanta, Georgia 30332
1 shared publicationJake Adam Vincent
Department of Neuroscience, Cell Biology and Physiology, Wright State University, Dayton, Ohio 45435
1 shared publication
Latest Publications
- Open Access
- 15 November 2026
- Published by The Company of Biologists in Journal of Experimental Biology
- Vol. 229 (22)
Emulating the influence of exoskeleton stiffness on primary afferent feedback in rat isolated muscle–tendon unit
Exoskeletons assist and augment movement, but their effects on proprioceptive feedback remain poorly understood because of challenges in making direct measures of sensory signals in humans. Here, we leveraged an animal model to explore how mechanical context akin to an elastic exoskeleton operating on a human lower limb joint influences primary muscle spindle firing. In an anesthetized rat preparation, we applied controlled stretches to the medial gastrocnemius with engineered springs (0–0.5 N mm−1) in parallel to the muscle–tendon unit (MTU) while modulating muscle activation to maintain overall system stiffness. Fascicle length was measured with sonomicrometry, force and MTU length with a servo motor, and spindle instantaneous firing rate (IFR) using dorsal root recordings. Trading off increases in exoskeleton stiffness with reductions in muscle activation decreased biological muscle force (3.1±0.6 N to 1.6±0.6 N, P<0.001) and stiffness (4.4±1.5 N mm−1 to 2.3±1.3 N mm−1, P<0.01), and increased fascicle length (7.9±1.3 mm to 8.3±1.5 mm, P<0.005). We found significant correlations between spindle firing and each independent fascicle dynamics factor we investigated (P<0.005). Thus, parallel stiffness modified muscle fascicle dynamics but did not alter spindle firing, possibly due to internal trade-offs in the salient fascicle dynamics that drive spindle behavior. Leveraging in situ experiments that enable monitoring of afferent feedback in complex mechanical contexts such as added parallel stiffness can provide a window into the effects of wearable devices on underlying sensory systems.
- 15 November 2026
- Published by The Company of Biologists in Journal of Experimental Biology
- Vol. 229 (22)
Open AccessEmulating the influence of exoskeleton stiffness on primary afferent feedback in rat isolated muscle–tendon unit
Exoskeletons assist and augment movement, but their effects on proprioceptive feedback remain poorly understood because of challenges in making direct measures of sensory signals in humans. Here, we leveraged an animal model to explore how mechanical context akin to an elastic exoskeleton operating on a human lower limb joint influences primary muscle spindle firing. In an anesthetized rat preparation, we applied controlled stretches to the medial gastrocnemius with engineered springs (0–0.5 N mm−1) in parallel to the muscle–tendon unit (MTU) while modulating muscle activation to maintain overall system stiffness. Fascicle length was measured with sonomicrometry, force and MTU length with a servo motor, and spindle instantaneous firing rate (IFR) using dorsal root recordings. Trading off increases in exoskeleton stiffness with reductions in muscle activation decreased biological muscle force (3.1±0.6 N to 1.6±0.6 N, P<0.001) and stiffness (4.4±1.5 N mm−1 to 2.3±1.3 N mm−1, P<0.01), and increased fascicle length (7.9±1.3 mm to 8.3±1.5 mm, P<0.005). We found significant correlations between spindle firing and each independent fascicle dynamics factor we investigated (P<0.005). Thus, parallel stiffness modified muscle fascicle dynamics but did not alter spindle firing, possibly due to internal trade-offs in the salient fascicle dynamics that drive spindle behavior. Leveraging in situ experiments that enable monitoring of afferent feedback in complex mechanical contexts such as added parallel stiffness can provide a window into the effects of wearable devices on underlying sensory systems.
- Open Access
Oxaliplatin Induces Spontaneous Firing at Sensory Endings Across Touch and Proprioceptive Afferents
Spontaneous activity in primary sensory neurons has been implicated in neuropathic symptoms, yet its earliest origins and immediate functional consequences remain incompletely understood. This gap is especially consequential in chemotherapy-induced peripheral neuropathy (CIPN), where sensory toxicities commonly limit effective cancer treatment. Using in vivo recordings in rats, we show that a single dose of oxaliplatin (OX) induces spontaneous firing within 24 h across touch and proprioceptive low-threshold mechanoreceptor (LTMR) afferents. Spontaneous firing consistently originated distally in peripheral axons and was accompanied by enhanced responses to mechanical stimulation, identifying LTMR sensory endings as the earliest source of spontaneous firing and a common site for spontaneous and stimulus-evoked hyperexcitability. OX also induced early structural abnormalities at sensory endings; however, SF+ LTMRs retained mechanosensory response profiles, indicating that spontaneous firing can emerge within otherwise functional sensory endings. Although coincident spontaneous and stimulus-evoked activity distorted encoding in individual LTMRs, these effects had little impact on population LTMR responses or motor behavior relying on mechanosensory feedback. Together, these findings identify sensory endings as an early target of OX neurotoxicity and demonstrate that spontaneous firing spanning multiple tactile and proprioceptive LTMR submodalities can coexist with largely preserved sensory function, indicating that even broad engagement across mechanosensory pathways is insufficient to disrupt all LTMR-dependent functions. These observations indicate that abnormal afferent activity initiated at sensory endings may be sufficient to engage sensory pathways underlying some paresthetic symptoms while leaving others largely unaffected, whereas progression to chronic neuropathic symptoms may require subsequent recruitment of the dorsal root ganglion. Highlights: Oxaliplatin rapidly induces spontaneous firing across touch and proprioceptors. The earliest spontaneous firing localizes to sensory endings, not the DRG. Sensory endings are a shared site of spontaneous and evoked hyperexcitability. Spontaneous firing engages some sensory pathways while sparing others.
Open AccessOxaliplatin Induces Spontaneous Firing at Sensory Endings Across Touch and Proprioceptive Afferents
Spontaneous activity in primary sensory neurons has been implicated in neuropathic symptoms, yet its earliest origins and immediate functional consequences remain incompletely understood. This gap is especially consequential in chemotherapy-induced peripheral neuropathy (CIPN), where sensory toxicities commonly limit effective cancer treatment. Using in vivo recordings in rats, we show that a single dose of oxaliplatin (OX) induces spontaneous firing within 24 h across touch and proprioceptive low-threshold mechanoreceptor (LTMR) afferents. Spontaneous firing consistently originated distally in peripheral axons and was accompanied by enhanced responses to mechanical stimulation, identifying LTMR sensory endings as the earliest source of spontaneous firing and a common site for spontaneous and stimulus-evoked hyperexcitability. OX also induced early structural abnormalities at sensory endings; however, SF+ LTMRs retained mechanosensory response profiles, indicating that spontaneous firing can emerge within otherwise functional sensory endings. Although coincident spontaneous and stimulus-evoked activity distorted encoding in individual LTMRs, these effects had little impact on population LTMR responses or motor behavior relying on mechanosensory feedback. Together, these findings identify sensory endings as an early target of OX neurotoxicity and demonstrate that spontaneous firing spanning multiple tactile and proprioceptive LTMR submodalities can coexist with largely preserved sensory function, indicating that even broad engagement across mechanosensory pathways is insufficient to disrupt all LTMR-dependent functions. These observations indicate that abnormal afferent activity initiated at sensory endings may be sufficient to engage sensory pathways underlying some paresthetic symptoms while leaving others largely unaffected, whereas progression to chronic neuropathic symptoms may require subsequent recruitment of the dorsal root ganglion. Highlights: Oxaliplatin rapidly induces spontaneous firing across touch and proprioceptors. The earliest spontaneous firing localizes to sensory endings, not the DRG. Sensory endings are a shared site of spontaneous and evoked hyperexcitability. Spontaneous firing engages some sensory pathways while sparing others.
- Open Access
Influence of exoskeleton stiffness on primary afferent feedback during stretch perturbations of isolated muscle-tendon unit
Exoskeletons assist and augment human movement, but their effects on proprioceptive feedback remain poorly understood. We examined how parallel exoskeleton stiffness influences primary muscle spindle firing. In an anesthetized rat preparation, controlled stretches of the medial gastrocnemius were applied with springs (0–0.5 N/mm) attached in parallel to the muscle-tendon unit (MTU) to simulate passive exoskeleton assistance. Fascicle length was measured with sonomicrometry, force and MTU length with a servo motor, and spindle instantaneous firing rate (IFR) with dorsal root recordings. Increasing exoskeleton stiffness decreased biological muscle force (3.1 ± 0.6 N to 1.6 ± 0.6 N, p < 0.001) and stiffness (4.4 ± 1.5 N/mm to 2.3 ± 1.3 N/mm, p < 0.01), while fascicle length increased (7.9 ± 1.3 mm to 8.3 ± 1.5 mm, p < 0.005). Despite these altered mechanics, spindle firing did not significantly change, and showed weak correlations with muscle length, velocity, force, and yank (R 2 ≤ 0.14). These results indicate that exoskeleton stiffness modifies fascicle dynamics without altering spindle firing. Previously proposed models of primary afferent firing did not sufficiently explain these results. This is the first in situ investigation of exoskeleton effects on primary afferent feedback during active contractions.
Open AccessInfluence of exoskeleton stiffness on primary afferent feedback during stretch perturbations of isolated muscle-tendon unit
Exoskeletons assist and augment human movement, but their effects on proprioceptive feedback remain poorly understood. We examined how parallel exoskeleton stiffness influences primary muscle spindle firing. In an anesthetized rat preparation, controlled stretches of the medial gastrocnemius were applied with springs (0–0.5 N/mm) attached in parallel to the muscle-tendon unit (MTU) to simulate passive exoskeleton assistance. Fascicle length was measured with sonomicrometry, force and MTU length with a servo motor, and spindle instantaneous firing rate (IFR) with dorsal root recordings. Increasing exoskeleton stiffness decreased biological muscle force (3.1 ± 0.6 N to 1.6 ± 0.6 N, p < 0.001) and stiffness (4.4 ± 1.5 N/mm to 2.3 ± 1.3 N/mm, p < 0.01), while fascicle length increased (7.9 ± 1.3 mm to 8.3 ± 1.5 mm, p < 0.005). Despite these altered mechanics, spindle firing did not significantly change, and showed weak correlations with muscle length, velocity, force, and yank (R 2 ≤ 0.14). These results indicate that exoskeleton stiffness modifies fascicle dynamics without altering spindle firing. Previously proposed models of primary afferent firing did not sufficiently explain these results. This is the first in situ investigation of exoskeleton effects on primary afferent feedback during active contractions.