QCQingping Chen

Qingping Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Qingping Chen has a total of 51 co-authors. Here are the top co-authors by number of shared publications:

  • Maxim Zaitsev

    Division of Medical Physics, Department of Radiology, Faculty of Medicine, University Medical Center Freiburg, University of Freiburg, Freiburg, Germany

    5 shared publications
  • Sebastian Littin

    Division of Medical Physics, Department of Diagnostic and Interventional Radiology, Medical Center, University of Freiburg, Faculty of Medicine University of Freiburg Freiburg Germany

    3 shared publications
  • Ariel J. Hannum

    Department of Radiology Stanford University Stanford California USA

    2 shared publications
  • Cai Wan

    Division of Medical Physics, Department of Radiology, Faculty of Medicine, University Medical Center Freiburg, University of Freiburg, Freiburg, Germany

    2 shared publications
  • Eric Arbes

    Division of Medical Physics, Department of Radiology, University Medical Center Freiburg, Faculty of Medicine University of Freiburg Freiburg Germany

    2 shared publications
  • Jon-Fredrik Nielsen

    Department of Biomedical Engineering, University of Michigan, Ann Arbor, USA

    2 shared publications

Latest Publications

  • Open Access

    Stim‐ CODE : PNS and CNS Constraint Optimized Diffusion‐Encoding for Neuroimaging on 200 mT /m Whole‐Body Gradients

    by Ariel J. Hannum, Michael Loecher, Qingping Chen, Eric Arbes, Kawin Setsompop, Maxim Zaitsev, Daniel B. Ennis

    Purpose: Ultra‐high‐performance whole‐body MRI gradients ( 200mT/m, 200 T/m/s) can reduce echo times (TE) in diffusion‐weighted imaging (DWI), improving SNR. However, full hardware utilization is limited by cardiac (CNS) and peripheral (PNS) nerve stimulation thresholds. This work demonstrates Stimulation Constraint Optimized diffusion‐encoding (Stim‐CODE) for neuro diffusion. Methods: Stim‐CODE uses the gradient optimization (GrOpt) toolbox to optimally design diffusion‐encoding gradient waveforms subject to a CNS or PNS “constraint envelope” based on other gradient events in the sequence. Stim‐CODE was evaluated in simulations and in vivo protocols with in‐plane resolutions of 1.5 1.5 mm and 1.0 1.0 mm across G = [45, 80, 200] mT/m and T/m/s. Healthy volunteers ( N = 10) underwent neuro DWI at b = 1000 s/mm with Monopolar, Stim‐CODE‐, Bipolar, and Stim‐CODE‐ encoding. SNR, apparent diffusion coefficient (ADC) maps, and ADC uncertainty were quantified. One volunteer underwent DTI with the same encoding schemes acquired at = [1000, 3000]s/mm. Results: Stim‐CODE reduced TEs across all ‐values, with larger gains for higher resolutions, greater G, and ‐nulled waveforms. Phantom and in vivo experiments confirmed equivalent diffusion‐weighting with TE savings and SNR improvements. Stim‐CODE‐ had significant SNR gains over Bipolar scans, but some differences in global ADC were observed. DTI metrics were similar across scans, with Stim‐CODE showing lower uncertainty. Conclusion: Stim‐CODE maximizes hardware capabilities to achieve time‐optimized diffusion‐encoding while respecting CNS and PNS, enabling similar diffusion‐weighting as conventional approaches with reduced TE and higher SNR.

  • Open Access

    Correction: Automated, open-source, vendor-independent quality assurance protocol based on the Pulseq framework

    by Qingping Chen, Niklas Wehkamp, Cai Wan, Patrick Hucker, Martin Büchert, Sebastian Littin, Jon-Fredrik Nielsen, Maxim Zaitsev

  • Open Access

    OpenMRF : A Modular, Vendor‐Neutral Open‐Source Framework for Magnetic Resonance Fingerprinting Using Pulseq

    by Tom Griesler, Jannik Stebani, Sydney Kaplan, Ivaylo Angelov, Petra Albert, Tobias Wech, Martin Blaimer, Xiang Wang, Qingping Chen, Maxim Zaitsev, et al.

    Purpose: Widespread adoption and methodological advancement of magnetic resonance fingerprinting (MRF) are limited by the lack of unified, reproducible implementation frameworks and fragmented open‐source tools. To address these barriers, we introduce OpenMRF—a comprehensive Pulseq‐based solution—designed to enable standardized and transferable MRF research across vendors, sites, and field strengths. Methods: OpenMRF integrates modular Pulseq‐based sequence design, Bloch‐equation‐based dictionary generation directly from . seq files, and iterative low‐rank subspace reconstruction. The framework was evaluated through digital phantom simulations, a multi‐site ISMRM/NIST phantom study on Siemens MRI systems at 0.55, 1.5, and 3 T, as well as GE and United Imaging 3 T platforms, and representative in vivo acquisitions in the liver (0.55 T), myocardium (1.5 T), and brain (3 T). Results: Simulations demonstrated high mapping accuracy in an ISMRM/NIST‐like digital phantom, with low‐rank reconstruction yielding deviations of 0.03% ± 0.32% (T 1 ) and 0.12% ± 1.94% (T 2 ). The multi‐site phantom study yielded relaxation times consistent with reference values at all field strengths, with mean deviations of −0.1% ± 2.9% (T 1 ), −1.5% ± 8.7% (T 2 ), and −4.0% ± 7.2% (T 1ρ ). In vivo acquisitions produced high‐quality parameter maps across different anatomical applications and field strengths. Conclusion: OpenMRF provides a robust, open‐source, end‐to‐end Pulseq‐based solution for MRF designed to enable reproducible sequence implementation, physics‐accurate dictionary simulation, and advanced reconstruction across vendors and field strengths. By providing a unified platform for method development, comparison, and cross‐vendor application, OpenMRF aims to accelerate reproducible and harmonized quantitative MRI research within the community.


  • Open Access

    An Open‐Source, Reproducible MRI Data Acquisition and Reconstruction Workflow Using Pulseq: Multi‐Site and Cross‐Vendor Validation

    by Qingping Chen, Thomas H. M. Roos, Amaya Murguia, Yuhai Xie, Zheng Liu, Pengcheng Xu, Shohei Fujita, Sebastian Littin, Yogesh Rathi, Jiayu Zhu, et al.

    Purpose: Reproducibility in MRI is limited by variability in data acquisition, formatting, and reconstruction across sites and vendors. This work aimed to mitigate these challenges through an open‐source, vendor‐independent workflow originally developed for the 2023–24 ISMRM Repeat It with Me: Reproducibility Team Challenge . Methods: Pulseq, extended with advanced features including LABELs and Sequence Definitions for k‐space description and execution instructions, was used to harmonize data acquisition. Pulseq‐generated raw k‐space data were converted into the MRD format using these metadata. Open‐source, vendor‐independent image reconstruction and post‐processing were performed with Gadgetron. Additionally, vendor‐native online reconstructions on Siemens platforms (ICE and OpenRecon) were enabled for Pulseq‐based sequences. The workflow was validated using MPRAGE and EPI protocols in phantoms and in vivo across nine scanners from five sites and four vendors. Vendor‐native acquisition and reconstruction protocols were executed for comparison. Results: Pulseq‐based sequences executed successfully on all systems, with all data converted and reconstructed without errors. Pulseq‐based, Gadgetron‐reconstructed images showed good agreement with corresponding vendor‐native images across scanners; however, qualitative and quantitative differences remained. Despite detailed natural‐language descriptions and meticulous console configuration, vendor‐native protocols introduced subtle but notable cross‐platform differences in sequence execution and reconstruction. In contrast, the proposed workflow achieved highly consistent sequence execution via Pulseq and standardized reconstruction through Gadgetron across scanners. Conclusion: We established an open‐source MRI workflow that harmonizes data acquisition, formatting, and reconstruction across sites and vendors. This workflow represents a critical step toward fully open and reproducible MRI, facilitating transparency, standardization, and collaboration across the research community.


  • Open Access

    Comparative Performance Analysis of an Open Source Motion‐Compensated Cardiac Diffusion Sequence Across Different MRI Systems and Gradient Strengths—A Pilot Study

    by Eric Arbes, Ariel Hannum, Johannes Fischer, Qingping Chen, Sebastian Littin, Alexander Maier, Michael Bock, Simon Reiss

    Purpose: To validate the performance of an open‐source cardiac diffusion sequence framework and to investigate hardware‐based performance differences. Methods: Three second order motion compensated sequence files were compiled using Pulseq and applied across different MRI systems to image five volunteers. DTI and SNR analysis was performed to investigate protocol efficacy. Results: The sequences performed well at the task of imaging short axis views of the myocardium and producing data suitable for diffusion tensor imaging analysis. Significant differences in sequence performance across different systems and within the same system were revealed. Relative SNR utilizing the strongest available gradient system yielded up to 80% more SNR than the weakest tested system. Relative SNR obtained from the same sequence at different scanners differed by up to 42%, suggesting hardware impacts that warrant further investigation. Conclusion: The presented sequence framework allows for an easy starting point into cardiac diffusion tensor imaging and opens the door to further analysis of hardware impacts on performance.

  • Open Access

    Quadruple‐refocused spin‐locking: A robust method for high‐amplitude T1ρ imaging

    by Cai Wan, Maximilian Gram, Wei He, Zheng Xu, Qingping Chen, Sebastian Littin, Thomas Lange, Maxim Zaitsev

    Purpose: Longitudinal relaxation time in the rotating frame (T1ρ) is a source of tissue‐specific contrasts, with applications in detecting myocardial fibrosis, liver fibrosis, and early‐stage osteoarthritis. However, T1ρ measurements are sensitive to static (B0) and radiofrequency (B1) magnetic field inhomogeneities. Improving the accuracy of T1ρ quantification can enable earlier and more reliable detection of pathological changes, providing a basis for early intervention. Therefore, we have developed an improved, quadruple‐refocused spin‐locking (QR‐SL) technique based on existing preparation schemes to obtain a more robust compensation for B0 and B1 field inhomogeneities.Methods: The QR‐SL module consists of four 180° refocusing pulses with opposite phases and five spin‐locking (SL) pulses with phase cycling according to the rotary‐echo principle. The performance of the proposed QR‐SL module is evaluated through numerical simulations and experimental validation in comparison to composite‐SL (C‐SL), balanced‐SL (B‐SL), and triple‐refocused‐SL (TR‐SL) preparation modules.Results: Numerical simulations indicate that the QR‐SL module demonstrates improved tolerance to a range of B0 and B1 field inhomogeneities compared to the other three modules. In scenarios involving inhomogeneities of both fields, the experimental results show that the residual sum of squares of the QR‐SL module was decreased by 24.3%, 68.9%, and 12.5% for in vivo knee cartilage, respectively, compared to the composite SL, balanced SL, and triple‐refocused SL preparation modules.Conclusion: The QR‐SL module has the potential to produce more accurate T1ρ maps, while minimizing artifacts. Consequently, the QR‐SL module is more favorable for T1ρ quantification, especially for low‐field and ultralow‐field quantitative MRI.


  • Open Access

    Automated, open-source, vendor-independent quality assurance protocol based on the Pulseq framework

    by Qingping Chen, Niklas Wehkamp, Cai Wan, Patrick Hucker, Martin Büchert, Sebastian Littin, Jon-Fredrik Nielsen, Maxim Zaitsev

    Objectives: Consistent image quality and signal stability are crucial for neuroimaging, particularly fMRI studies that rely on detecting small BOLD signal changes. Regular MR system performance monitoring is essential, especially for longitudinal and multi-site studies. This work aims to establish a robust quality assurance (QA) protocol to enhance data comparability across days, scanner versions, vendors, and sites. Materials and methods: We implemented an open-source, vendor-independent QA protocol using Pulseq for standardized data acquisition and ISMRMRD/Gadgetron for harmonized image reconstruction, accompanied by an automated post-processing pipeline to evaluate structural and temporal image quality. The protocol was thoroughly tested on three Siemens 3T scanners with different software versions at one site, and one GE 3T scanner at another site. The test was repeated on an fBIRN phantom for at least 4 days. Results: The vendor-independent protocol produced image quality comparable to a closely matched vendor-based protocol. It showed similar day-to-day repeatability to the vendor-based protocol across the Siemens scanners and high inter-day repeatability on the GE scanner. Conclusion: We successfully developed and implemented an open-source, vendor-independent QA protocol, accompanied by an automated post-processing pipeline. The results demonstrate the feasibility and repeatability of the protocol across different days, system versions, vendors, and sites.


  • Open Access

    Compressed Sensing in Sodium Magnetic Resonance Imaging: Techniques, Applications, and Future Prospects

    by Qingping Chen, N. Jon Shah, Wieland A. Worthoff

    Sodium (23Na) yields the second strongest nuclear magnetic resonance (NMR) signal in biological tissues and plays a vital role in cell physiology. Sodium magnetic resonance imaging (MRI) can provide insights into cell integrity and tissue viability relative to pathologies without significant anatomical alternations, and thus it is considered to be a potential surrogate biomarker that provides complementary information for standard hydrogen (1H) MRI in a noninvasive and quantitative manner. However, sodium MRI suffers from a relatively low signal‐to‐noise ratio and long acquisition times due to its relatively low NMR sensitivity. Compressed sensing‐based (CS‐based) methods have been shown to accelerate sodium imaging and/or improve sodium image quality significantly. In this manuscript, the basic concepts of CS and how CS might be applied to improve sodium MRI are described, and the historical milestones of CS‐based sodium MRI are briefly presented. Representative advanced techniques and evaluation methods are discussed in detail, followed by an expose of clinical applications in multiple anatomical regions and diseases as well as thoughts and suggestions on potential future research prospects of CS in sodium MRI.Evidence Level: 5Technical Efficacy: Stage 1