Abstract
This paper proposes a fault-tolerant strategy to recover the full performance of modular multilevel converter (MMC) under sub-module (SM) fault condition for regenerative medium-voltage drive application. The proposed method has the feature to retrieve line voltage amplitude during post-fault condition back to its nominal value. In this method, missing capacity of converter due to fault condition is compensated by all remaining healthy SMs. The main advantage of proposed method in comparison with previous works is that it imposes a lower voltage stress on switches in post-fault condition without severe circulating current. Remaining healthy SMs, also, operate at a similar condition which leads to the feature of homogeneous distribution of loss and temperature in all parts of the converter. The proposed method is applicable for regenerative MMC-based drives as well as back-to-back configuration of MMC without adding cost or complexity to whole system. A generalized approach is presented and its result compared with other methods. Simulation and experimental results are provided to validate performance and feasibility of the proposed method which can effectively enhance the fault-tolerant capability of this converter.
Funding Information
  • Iran National Science Foundation and Alexander von Humboldt Foundation, Germany

This publication has 36 references indexed in Scilit: