Abstract
Background: Double kissing crush (DKC) is a preferred two‐stent technique for complex coronary bifurcation lesions. Proximal cell rewiring is routinely recommended to reduce technical failure, and DKC is considered effective across various bifurcation angles. However, it remains unclear whether this standard approach is optimal for all patients. Aims: This study investigates the interaction between bifurcation angle and rewiring configuration to identify anatomy‐specific strategies. Methods: Computational modeling of the DKC procedure was used to simulate 12 DKC procedures across three left main bifurcation angles (45°, 70°, and 100°) and four rewiring configurations: proximal−proximal (P−P), proximal−distal (P−D), distal−proximal (D−P), and distal−distal (D−D). Evaluation metrics included stent malapposition, side branch ostium clearance, arterial wall stress, low time‐averaged endothelial shear stress, and high shear rates. Results: DKC performed in wide bifurcations (100°) resulted in worse outcomes, with malapposition reaching 18%, side branch clearance down to 23%, and up to twice the exposure to adverse high shear rates compared to narrower angles. In contrast, intermediate (70°) and narrow (45°) angles generally resulted in more favorable outcomes, though optimal rewiring varied by angle. Proximal strategies, that is, P−P and P−D, were most effective at 70°, while D−D performed best at 45°. No single strategy was consistently superior across all bifurcation angles. Conclusions: DKC outcomes depend on bifurcation angle and can be optimized by tailoring rewiring strategies, challenging the current clinical understanding. These findings support anatomy‐specific procedural planning and intravascular imaging to guide rewiring. This study provides a mechanistic rationale to improve clinical decision‐making and tailor bifurcation interventions.Keywords
All Related Versions
This publication has 44 references indexed in Scilit:
- Are Ultrathin Stents Optimal for Bifurcation Lesions? Insights From Computational Modeling of Provisional and DK‐Crush TechniquesCatheterization and Cardiovascular Interventions, 2025
- Advancements in Coronary Bifurcation Stenting Techniques: Insights From Computational and Bench Testing StudiesInternational Journal for Numerical Methods in Biomedical Engineering, 2025
- Reliability of characterising coronary artery flow with the flow-split outflow strategy: Comparison against the multiscale approachComputer Methods and Programs in Biomedicine, 2025
- A review on the use of finite element simulations for structural analyses of coronary stenting: What can we do nowadays and what do we need to move forward?European Journal of Mechanics - A/Solids, 2023
- European Bifurcation Club white paper on stenting techniques for patients with bifurcated coronary artery lesionsCatheterization and Cardiovascular Interventions, 2020
- Biomechanical Impact of Wrong Positioning of a Dedicated Stent for Coronary Bifurcations: A Virtual Bench Testing StudyCardiovascular Engineering and Technology, 2018
- Hemodynamics in Idealized Stented Coronary Arteries: Important Stent Design ConsiderationsAnnals of Biomedical Engineering, 2015
- Construction of a Coronary Artery Atlas from CT Angiography2014
- Computational fluid dynamics of stented coronary bifurcations studied with a hybrid discretization methodEuropean Journal of Mechanics - B/Fluids, 2012
- Hemodynamic Shear Stress and Its Role in AtherosclerosisJAMA, 1999