Optical aberrations, accommodation, and visual acuity with a bioanalogic continuous focus intraocular lens after cataract surgery
Open Access
- 1 December 2017
- journal article
- Published by Medknow in Journal of Current Ophthalmology
- Vol. 29 (4) , 274-281
Abstract
To evaluate the visual outcomes, pseudoaccommodation, and wavefront aberrometry after implantation of Wichterle IOL-Continuous Focus (WIOL-CF®, Gelmed International, Kamenne Zehrovice, Czech Republic) by i-Trace aberrometry. In this retrospective interventional case series study, after cataract surgery with implantation of accommodative WIOL-CF®, the patients were evaluated with i-Trace aberrometer for measurement of modulation transfer function (MTF), point spread function (PSF), total aberrations, higher order aberrations (HOAs) at far and near and pseudoaccommodation. The pre and postoperative visual acuity at near and distance were also measured. Forty eyes of 20 patients (aged 40-77 years) were enrolled in this study with mean follow-up time of up 13.10 ± 5.52 months. The mean logMAR corrected distance visual acuity (CDVA) improved from 0.20 ± 0.14 preoperatively to 0.10 ± 0.09 at the last follow-up after surgery (P = 0.002). The results were 60% J1, 70% J2, 85% J3, 90% J4, 95% J5 and 100% for J6. The mean pseudoaccommodation, range of accommodation volume, and average of peak accommodation were -2.52 ± 1.56 diopters (D), 1.50 to 5.25 D and -3.25 ± 1.25 D, respectively. The mean MTF at 5 cycles per degree at far was 0.200 ± 0.10 and for near was 0.207 ± 0.10. PSF at far and near was 0.0002 and 0.001, respectively. The mean root mean square (RMS) value of HOAs; total, coma spherical aberration, trefoil, and secondary astigmatism were 1.08 ± 0.48 μm, 0.89 ± 0.45 μm, -0.33 ± 0.23 μm, 0.25 ± 0.17 μm, and 0.15 ± 0.13 μm for far and 0.88 ± 0.49 μm, 0.73 ± 0.46 μm, -0.25 ± 0.22 μm, 0.19 ± 0.16 μm and 0.11 ± 0.10 μm for near, respectively. There was a decrease in HOAs at near relative to far (P < 0.05). WIOL-CF® seems to be an acceptable accommodative intraocular lens (IOL) in terms of uncorrected near and distant visual outcomes, MTF and HOA.Keywords
This publication has 18 references indexed in Scilit:
- Objective Accommodation Measurement of the Crystalens HD Compared to Monofocal Intraocular LensesJournal of Refractive Surgery, 2013
- Real and Pseudoaccommodation in Accommodative LensesJournal of Ophthalmology, 2011
- Visual function and spectacle independence after cataract surgery: Bilateral diffractive multifocal intraocular lenses versus monovision pseudophakiaJournal of Cataract & Refractive Surgery, 2011
- Wavefront analysis and modulation transfer function of three multifocal intraocular lensesIndian Journal Of Ophthalmology, 2010
- Objective accommodation measurements in pseudophakic subjects using an autorefractor and an aberrometerJournal of Cataract & Refractive Surgery, 2009
- Meta-analysis of accommodating intraocular lensesJournal of Cataract & Refractive Surgery, 2007
- Clinical evaluation of the Crystalens AT-45 accommodating intraocular lensJournal of Cataract & Refractive Surgery, 2006
- Accommodation measurements in a prepresbyopic and presbyopic populationJournal of Cataract & Refractive Surgery, 2004
- High-order aberrations in pseudophakia with different intraocular lensesJournal of Cataract & Refractive Surgery, 2004
- Multifocal versus monofocal intraocular lenses in cataract surgeryOphthalmology, 2003