Asymmetric Capacitive Pixel Array (E-CaP) for Mapping of Epidermal Vectored Movement
- 26 April 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal on Flexible Electronics
- Vol. 1 (2) , 134-140
Abstract
We demonstrate a 3×3 Epidermal asymmetric Capacitive Pixel array (E-CaP) with direction-sensitive capabilities. The conformally laminated E-CaP has a capacitive sensing mechanism and effectively maps the direction and the pressure of epidermal movements. The difference in the previously retained and the present value of the response represents the rate of change of capacitance. This rate of change per unit displacement is crucial to determine the vectored response of the strain-induced in the E-CaP. The nominal capacitance of the array is 3.370 pF and shows a prominent change (d) of 1.341î+2.007ĵ+8.750k pF/mm. The micro-meshed (μ-meshed) PDMS structure is fabricated using SU-8 μ-mould and is sandwiched between the asymmetric electrodes. The μ-meshed design offers greater shear displacement, allowing the E-CaP to move conformally with the skin. The possible movement domain associated with the limbs that are laminated with E-CaP can map the entire generated vector response (directional specific). The E-CaP is simulated and tested for mapping the directional sensitive epidermal movement.Keywords
This publication has 24 references indexed in Scilit:
- Technology in Parkinson's disease: Challenges and opportunitiesMovement Disorders, 2016
- Haptic Edge Detection Through ShearScientific Reports, 2016
- A novel all-elastomer MEMS tactile sensor for high dynamic range shear and normal force sensingJournal of Micromechanics and Microengineering, 2015
- Wearable Sensors for Human Activity Monitoring: A ReviewIEEE Sensors Journal, 2014
- Development of a flexible three-axis tactile sensor based on screen-printed carbon nanotube-polymer compositeJournal of Micromechanics and Microengineering, 2014
- One-step surface modification for irreversible bonding of various plastics with a poly(dimethylsiloxane) elastomer at room temperatureLab on a Chip, 2014
- Parametric evaluation of shear sensitivity in piezoresistive interfacial force sensorsJournal of Micromechanics and Microengineering, 2011
- Tactile Sensing—From Humans to HumanoidsIEEE Transactions on Robotics, 2010
- Mechanism leading to the development of pressure ulcers based on shear force and pressures during a bed operation: Influence of body types, body positions, and knee positionsWound Repair and Regeneration, 2009
- Human tactile perception as a standard for artificial tactile sensing—a reviewThe International Journal of Medical Robotics and Computer Assisted Surgery, 2004