MGManu Garg

Manu Garg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Manu Garg has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Thermally Stable, BEOL-Configured MEMS-Based One-Time Programmable (OTP) Memory for Cryogenic Embedded Application

    by Khanjan Miteshkumar Joshi, Manu Garg, Nitish Kumar, Yi Chiu, Pushpapraj Singh

    In this letter, we demonstrate a MEMS-based one-time programmable(OTP) memory cell integrated into the back-end-of-line (BEOL) layers of a TSMC $0.35~\mu $ m 2P4M CMOS process, designed for operation down to 4 K. This novel design eliminates the need for fusing currents, relying instead on surface-adhesion phenomena for programming. The memory cells operate with a low read voltage of 0.05 V and read current of $80~\mu $ A, ensuring low power consumption and minimal heat generation (~2.8 K). The read resistance ranges from 0.5 to 5.5k $\Omega $ in the logic ‘1’ (ON-state) and ~2.4 T $\Omega $ in the logic ‘0’ (OFF-state), achieving an on-off ratio in the order of $10^{9}$ . The switching energy is limited to 0.5–2.6 pJ, with a demonstrated memory retention of 4 hours at 300, 120, and 4 K. These features make it highly suitable for storing micro-operations permanently in cryogenic embedded applications.[2025-0028]


  • Capacitorless MEMS-Based Temporary Memory (CMTM) With Extended Refresh Interval

    by Khanjan Miteshkumar Joshi, Manu Garg, Mujeeb Yosuf, Sushil Kumar, Pushpapraj Singh

    Microelectromechanical system (MEMS)-based mechanical memories are a promising solution in edge devices that require the usage of charge-free storage. Herein this article, we present a capacitorless MEMS-based temporary memory (CMTM) cell offering charge-free storage. This CMTM cell is capable of both memory access and bit storage thereby eliminating the need for multiple elements in a single-bit cell. The implementation of the CMTM cell relies on the structural engineering of the ratio $\xi $ between the surface adhesion force of the contact electrodes (source and drain) and the restoring force supplied by the actuating MEMS structure. Three different memory cells having $\xi $ values of 0.9, 0.7, and 0.6 are designed, fabricated, and tested for harnessing $\xi $ property for temporary storage. Fabricated CMOS-compatible memory cell having $\xi =0.9$ showcases a noteworthy refresh interval ( $\tau _{\text {hold}}$ ) of 100 ms. The retention characteristics of the programmed CMTM cell for one second are also demonstrated.

  • Ultrasensitive Reduced Vanadium Dioxide-Based MEMS Pirani Gauge with Extended Dynamic Range

    by Manu Garg, Khanjan Joshi, Dhairya S. Arya, Sushil Kumar, Mujeeb Yousuf, Ankur Goswami, Pushpapraj Singh

  • Open Access

    Electrostatically actuated all metal MEMS Pirani gauge with tunable dynamic range

    by Manu Garg, Dhairya Singh Arya, Sushil Kumar, Khanjan Joshi, Mujeeb Yousuf, Yi Chiu, Pushpapraj Singh

    An electrostatically actuated all-metal microelectromechanical systems (MEMS) Pirani gauge with a tunable dynamic range is proposed. Contrary to the conventional fixed gap Pirani gauges, an electrostatic mechanism is employed to tune the gaseous conduction gap. Due to the electrostatic force between the heating element and heat sink, this tuning results in shifting the transition pressure to a higher pressure. As a result, the operating range of the Pirani gauge can be tuned depending on the magnitude of the actuation voltage. Theoretical estimation of the transition pressure corresponding to different gaseous conduction gaps is also presented. Depending on the available margin of gap tuning, the electromechanical and electrothermal analyses are carried out in COMSOL Multiphysics. The analytical approach is validated by experimentally characterizing the fabricated device. The experimentally tested device with the proposed actuation mechanism shows an 11.2 dB increase in dynamic range in comparison to the conventional design. In a complementary metal-oxide-semiconductor (CMOS)-compatible fabrication process flow, the proposed gauge can be used to monitor vacuum from 40 Pa to 5 × 105 Pa with the electrostatic actuation.


  • Nanogap CMOS-MEMS Pirani Gauge Based on Titanium-Nitride Heating Element for Broad-Range Vacuum Characterization

    by Manu Garg, Pushpapraj Singh, Yi Chiu

    This article presents a titanium-nitride composite (TiN-C)-based complementary metal–oxide– semiconductor microelectromechanical system (CMOS-MEMS) Pirani gauge integrated into the back-end-of-line (BEOL) layers. A microbeam architecture is utilized as the sensing element consisting of a stack of TiN and SiO2. The structure utilizes the sandwiched (TiN/AlCu/TiN) metal line configuration to craft the suspended sensing element having a nanogap from the substrate. TiN serves as the heating element in the sensing element, while SiO2 provides mechanical support to the structure. Gauges with lengths varying from 60 to $90~\mu \text{m}$ are proposed, while the width is kept the same, i.e., $4~\mu \text{m}$ . Since the BEOL-integrated MEMS devices are prone to suffer from residual stress, an optical profilometer analysis is performed to quantify the effective value of the suspended gap. Furthermore, temperature profiles of the proposed designs are evaluated using COMSOL Multiphysics. Finally, the fabricated gauges are tested for pressure-dependent response from 1 to $10^{{6}}$ Pa and a performance comparison is established. In the monolithic CMOS-MEMS implementation, a lower detection limit of 15.5, 12.3, 10.3, and 8.3 Pa is obtained for different gauge lengths, while the upper detection range is the same, i.e., $10^{{6}}$ Pa.


  • Erratum: “Reducing solid conduction in electrothermally driven MEMS Pirani gauge using integrated polymeric thin film” [Appl. Phys. Lett. 120(8), 084101 (2022)]

    by Manu Garg, Dhairya S. Arya, Sushil Kumar, Yi Chiu, Pushpapraj Singh

    This article1 was originally published with an error in the affiliation information for the first and the fourth author. The corrected affiliations should appea

  • A Sensitive and Flexible Poroelastic Barium Titanate Matrix for Pressure Sensing Applications

    by Mujeeb Yousuf, Nadeem Tariq Beigh, Dhairya Singh Arya, Manu Garg, Dhiman Mallick, Pushpapraj Singh

    This paper reports on Poroelastic Barium Titanate Matrix (PBM) for flexible pressure sensor applications. The fabrication of PBM is a simple and cost-effective process that allows an optimized composition of polydimethylsiloxane (PDMS) and barium titanate (BTO) to penetrate through the sugar template via capillary action. The fabricated PBM undergoes large deformation if compared to the state-of-the-art pressure sensors. Around a twofold increase in sensitivity is observed with the appropriate weight percent (%) of BTO in PDMS and the %porosity in the PBM structure. The PBM generates a peak voltage of ∼1.1 V, whereas the non-porous composite (BTO+PDMS) generates only ∼500 mV. The response of PBM is highly linear (coefficient of linearity 0.983) and repeatable with a deviation of 0.47%. Furthermore, the operating range of PBM is 5-100 kPa. Finite Element simulations are carried out to find the relation between the substrate porosity, % weight ratio of BTO, and the generated voltage. The optimized PBM can be exploited for applications like gait biomechanics.


  • Skin-Inspired Bimodal Magneto-Dielectric-Based Flexible and Sensitive Capacitive Sensor for Limb Motion Tracking

    by Mujeeb Yousuf, Manu Garg, Dhairya Singh Arya, Pushpapraj Singh

    Flexible devices featuring bimodality finds wide application in wearable electronics for tracking simple-to-complex human activities. Such tracking requires high sensitivity and broad working range which is still a concern for wearable electronics. Herein, a magneto-dielectric layer (MDL)-based bimodal sensing (strain and proximity) device with a broad working range and higher sensitivity is proposed. Nanoparticles in MDL (magnetic nanoparticles (MNP) within the PDMS matrix) change their position dynamically ( ${g}{\rightarrow }{g}^{\prime }$ ) according to different bending load conditions. Increased sensitivity ( $S_{ST}~\approx ~4\text{x}$ -times and $S_{Prox}~\approx ~1.5\text{x}$ -times) and wider working range (from 6 to 20 mm) are achieved in contrast to regular devices with PDMS as a dielectric. Linear device response (0.99 coefficient of linearity), long-endurance (1000 cycles), and rapid detection (200 and 250 ms) features add further advantages. Single capacitive readout and standard interdigitated electrodes (IDEs) simplify the device implementation. Moreover, IDE design automates contactless sensing along with identification of the nature of the sensing object (conducting/nonconducting), which is applied directly when it comes to object-sensitive human perception (e.g., visually impaired person).


  • Stress engineered SU-8 dielectric-microbridge based polymer MEMS Pirani gauge for broad range hermetic characterization

    by Manu Garg, Dhairya Singh Arya, Sushil Kumar, Mujeeb Yousuf, Yi Chiu, Pushpapraj Singh

    The paper introduces a SU-8 dielectric µ -bridge based polymer microelectromechanical systems (MEMS) Pirani gauge which can be employed for hermetic characterization of packaged electronic sensors. The µ -bridge structure is adopted due to its simplicity in fabrication and lower footprint, which makes it feasible for heterogeneous integration. Further, the integration of SU-8 polymer with the active thermistor offers superior thermal isolation from the substrate and extends the dynamic range. Before fabricating the actual device, the SU-8 based µ -bridge is optimized for stress-free release. A stress engineering is performed and thermal processing of SU-8 is optimized. The measurement results reveal that the removal of quenching from the baking steps leads to the successful fabrication of freely suspended µ -bridge with SU-8 polymer as a structural layer. A quantitative comparison of the proposed gauge is established by comparing the gauge performance with conventional dielectric materials like silicon dioxide (SiO 2 ), silicon nitride (Si 3 N 4 ), and aluminum oxide (Al 2 O 3 ). The fabricated SU-8 polymer-based MEMS Pirani gauge with a 40 µ m × 7 µ m footprint can be used for hermetic characterization from 30 Pa to 10 5 Pa and is an ideal candidate for heterogeneous integration.


  • Asymmetric Capacitive Pixel Array (E-CaP) for Mapping of Epidermal Vectored Movement

    by Mujeeb Yousuf, Dhairya Singh Arya, Manu Garg, Divyansh Varshney, Pushpapraj Singh

    We demonstrate a 3×3 Epidermal asymmetric Capacitive Pixel array (E-CaP) with direction-sensitive capabilities. The conformally laminated E-CaP has a capacitive sensing mechanism and effectively maps the direction and the pressure of epidermal movements. The difference in the previously retained and the present value of the response represents the rate of change of capacitance. This rate of change per unit displacement is crucial to determine the vectored response of the strain-induced in the E-CaP. The nominal capacitance of the array is 3.370 pF and shows a prominent change (d) of 1.341î+2.007ĵ+8.750k pF/mm. The micro-meshed (μ-meshed) PDMS structure is fabricated using SU-8 μ-mould and is sandwiched between the asymmetric electrodes. The μ-meshed design offers greater shear displacement, allowing the E-CaP to move conformally with the skin. The possible movement domain associated with the limbs that are laminated with E-CaP can map the entire generated vector response (directional specific). The E-CaP is simulated and tested for mapping the directional sensitive epidermal movement.