Dhairya Singh Arya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dhairya Singh Arya has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Pushpapraj Singh
Center of Applied Research in Electronics, Indian Institute of Technology Delhi, New Delhi, India
10 shared publications - Manu Garg
International College of Semiconductor Technology, National Yang Ming Chiao Tung University (NYCU), Hsinchu, Taiwan
9 shared publications - Sushil Kumar
Centre for Applied Research in Electronics (CARE), Indian Institute of Technology at Delhi (IITD), New Delhi, India
7 shared publications - Mujeeb Yousuf
Center of Applied Research in Electronics, Indian Institute of Technology Delhi, New Delhi, India
4 shared publications - Nikhil Chourasiya
Centre for Applied Research in Electronics, Indian Institute of Technology, New Delhi, India
2 shared publications Pushpapraj Singh
Centre for Applied Research in Electronics, IIT Delhi, New Delhi, India
2 shared publications
Latest Publications
- 31 May 2024
- Published by Springer Nature
- p. 311-318
Ultrasensitive Reduced Vanadium Dioxide-Based MEMS Pirani Gauge with Extended Dynamic Range
- 31 May 2024
- Published by Springer Nature
- p. 311-318
Ultrasensitive Reduced Vanadium Dioxide-Based MEMS Pirani Gauge with Extended Dynamic Range
- 2 October 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (14)
Erratum: “Reducing solid conduction in electrothermally driven MEMS Pirani gauge using integrated polymeric thin film” [Appl. Phys. Lett. 120(8), 084101 (2022)]
This article1 was originally published with an error in the affiliation information for the first and the fourth author. The corrected affiliations should appea
- 2 October 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (14)
Erratum: “Reducing solid conduction in electrothermally driven MEMS Pirani gauge using integrated polymeric thin film” [Appl. Phys. Lett. 120(8), 084101 (2022)]
This article1 was originally published with an error in the affiliation information for the first and the fourth author. The corrected affiliations should appea
- 30 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 7 (2) , 1-4
A Sensitive and Flexible Poroelastic Barium Titanate Matrix for Pressure Sensing Applications
This paper reports on Poroelastic Barium Titanate Matrix (PBM) for flexible pressure sensor applications. The fabrication of PBM is a simple and cost-effective process that allows an optimized composition of polydimethylsiloxane (PDMS) and barium titanate (BTO) to penetrate through the sugar template via capillary action. The fabricated PBM undergoes large deformation if compared to the state-of-the-art pressure sensors. Around a twofold increase in sensitivity is observed with the appropriate weight percent (%) of BTO in PDMS and the %porosity in the PBM structure. The PBM generates a peak voltage of ∼1.1 V, whereas the non-porous composite (BTO+PDMS) generates only ∼500 mV. The response of PBM is highly linear (coefficient of linearity 0.983) and repeatable with a deviation of 0.47%. Furthermore, the operating range of PBM is 5-100 kPa. Finite Element simulations are carried out to find the relation between the substrate porosity, % weight ratio of BTO, and the generated voltage. The optimized PBM can be exploited for applications like gait biomechanics.
- 30 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 7 (2) , 1-4
A Sensitive and Flexible Poroelastic Barium Titanate Matrix for Pressure Sensing Applications
This paper reports on Poroelastic Barium Titanate Matrix (PBM) for flexible pressure sensor applications. The fabrication of PBM is a simple and cost-effective process that allows an optimized composition of polydimethylsiloxane (PDMS) and barium titanate (BTO) to penetrate through the sugar template via capillary action. The fabricated PBM undergoes large deformation if compared to the state-of-the-art pressure sensors. Around a twofold increase in sensitivity is observed with the appropriate weight percent (%) of BTO in PDMS and the %porosity in the PBM structure. The PBM generates a peak voltage of ∼1.1 V, whereas the non-porous composite (BTO+PDMS) generates only ∼500 mV. The response of PBM is highly linear (coefficient of linearity 0.983) and repeatable with a deviation of 0.47%. Furthermore, the operating range of PBM is 5-100 kPa. Finite Element simulations are carried out to find the relation between the substrate porosity, % weight ratio of BTO, and the generated voltage. The optimized PBM can be exploited for applications like gait biomechanics.
- 2 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 70 (3) , 1338-1343
Skin-Inspired Bimodal Magneto-Dielectric-Based Flexible and Sensitive Capacitive Sensor for Limb Motion Tracking
Flexible devices featuring bimodality finds wide application in wearable electronics for tracking simple-to-complex human activities. Such tracking requires high sensitivity and broad working range which is still a concern for wearable electronics. Herein, a magneto-dielectric layer (MDL)-based bimodal sensing (strain and proximity) device with a broad working range and higher sensitivity is proposed. Nanoparticles in MDL (magnetic nanoparticles (MNP) within the PDMS matrix) change their position dynamically ( ${g}{\rightarrow }{g}^{\prime }$ ) according to different bending load conditions. Increased sensitivity ( $S_{ST}~\approx ~4\text{x}$ -times and $S_{Prox}~\approx ~1.5\text{x}$ -times) and wider working range (from 6 to 20 mm) are achieved in contrast to regular devices with PDMS as a dielectric. Linear device response (0.99 coefficient of linearity), long-endurance (1000 cycles), and rapid detection (200 and 250 ms) features add further advantages. Single capacitive readout and standard interdigitated electrodes (IDEs) simplify the device implementation. Moreover, IDE design automates contactless sensing along with identification of the nature of the sensing object (conducting/nonconducting), which is applied directly when it comes to object-sensitive human perception (e.g., visually impaired person).
- 2 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 70 (3) , 1338-1343
Skin-Inspired Bimodal Magneto-Dielectric-Based Flexible and Sensitive Capacitive Sensor for Limb Motion Tracking
Flexible devices featuring bimodality finds wide application in wearable electronics for tracking simple-to-complex human activities. Such tracking requires high sensitivity and broad working range which is still a concern for wearable electronics. Herein, a magneto-dielectric layer (MDL)-based bimodal sensing (strain and proximity) device with a broad working range and higher sensitivity is proposed. Nanoparticles in MDL (magnetic nanoparticles (MNP) within the PDMS matrix) change their position dynamically ( ${g}{\rightarrow }{g}^{\prime }$ ) according to different bending load conditions. Increased sensitivity ( $S_{ST}~\approx ~4\text{x}$ -times and $S_{Prox}~\approx ~1.5\text{x}$ -times) and wider working range (from 6 to 20 mm) are achieved in contrast to regular devices with PDMS as a dielectric. Linear device response (0.99 coefficient of linearity), long-endurance (1000 cycles), and rapid detection (200 and 250 ms) features add further advantages. Single capacitive readout and standard interdigitated electrodes (IDEs) simplify the device implementation. Moreover, IDE design automates contactless sensing along with identification of the nature of the sensing object (conducting/nonconducting), which is applied directly when it comes to object-sensitive human perception (e.g., visually impaired person).
- 21 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 6 (7) , 1-4
Zero-Biased and Broadband (0.1–1.5 THz) Terahertz Detector Using Dirac Semimetal-Platinum Telluride (PtTe2)
This letter demonstrates the Dirac semimetal-platinum telluride (PtTe 2 )-based terahertz detector. The reported detector has a broadband response ranging from 0.1 to 1.5 THz at room temperature. The antenna-coupled PtTe 2 device can perform at zero bias with a maximum responsivity of 16.4 A/W at 0.2 THz. In contrast, the two fold increase in responsivity is observed with bias (100 mV). Furthermore, even at the highest source frequency (1.5 THz), the detector at zero bias exhibits higher responsivity (6.1 A/W), lower noise-equivalent power (1.5 × 10 −11 WHz −1/2 ), and higher detectivity (5.3 × 10 9 cm·Hz 0.5 /W). Therefore, the proposed PtTe 2 -based detector manifests better performance than variously reported terahertz detectors. These improved device performances and one mask fabrication process validate their worth for detection and sensing in the terahertz domain.
- 21 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 6 (7) , 1-4
Zero-Biased and Broadband (0.1–1.5 THz) Terahertz Detector Using Dirac Semimetal-Platinum Telluride (PtTe2)
This letter demonstrates the Dirac semimetal-platinum telluride (PtTe 2 )-based terahertz detector. The reported detector has a broadband response ranging from 0.1 to 1.5 THz at room temperature. The antenna-coupled PtTe 2 device can perform at zero bias with a maximum responsivity of 16.4 A/W at 0.2 THz. In contrast, the two fold increase in responsivity is observed with bias (100 mV). Furthermore, even at the highest source frequency (1.5 THz), the detector at zero bias exhibits higher responsivity (6.1 A/W), lower noise-equivalent power (1.5 × 10 −11 WHz −1/2 ), and higher detectivity (5.3 × 10 9 cm·Hz 0.5 /W). Therefore, the proposed PtTe 2 -based detector manifests better performance than variously reported terahertz detectors. These improved device performances and one mask fabrication process validate their worth for detection and sensing in the terahertz domain.
- 26 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal on Flexible Electronics
- Vol. 1 (2) , 134-140
Asymmetric Capacitive Pixel Array (E-CaP) for Mapping of Epidermal Vectored Movement
We demonstrate a 3×3 Epidermal asymmetric Capacitive Pixel array (E-CaP) with direction-sensitive capabilities. The conformally laminated E-CaP has a capacitive sensing mechanism and effectively maps the direction and the pressure of epidermal movements. The difference in the previously retained and the present value of the response represents the rate of change of capacitance. This rate of change per unit displacement is crucial to determine the vectored response of the strain-induced in the E-CaP. The nominal capacitance of the array is 3.370 pF and shows a prominent change (d) of 1.341î+2.007ĵ+8.750k pF/mm. The micro-meshed (μ-meshed) PDMS structure is fabricated using SU-8 μ-mould and is sandwiched between the asymmetric electrodes. The μ-meshed design offers greater shear displacement, allowing the E-CaP to move conformally with the skin. The possible movement domain associated with the limbs that are laminated with E-CaP can map the entire generated vector response (directional specific). The E-CaP is simulated and tested for mapping the directional sensitive epidermal movement.
- 26 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal on Flexible Electronics
- Vol. 1 (2) , 134-140
Asymmetric Capacitive Pixel Array (E-CaP) for Mapping of Epidermal Vectored Movement
We demonstrate a 3×3 Epidermal asymmetric Capacitive Pixel array (E-CaP) with direction-sensitive capabilities. The conformally laminated E-CaP has a capacitive sensing mechanism and effectively maps the direction and the pressure of epidermal movements. The difference in the previously retained and the present value of the response represents the rate of change of capacitance. This rate of change per unit displacement is crucial to determine the vectored response of the strain-induced in the E-CaP. The nominal capacitance of the array is 3.370 pF and shows a prominent change (d) of 1.341î+2.007ĵ+8.750k pF/mm. The micro-meshed (μ-meshed) PDMS structure is fabricated using SU-8 μ-mould and is sandwiched between the asymmetric electrodes. The μ-meshed design offers greater shear displacement, allowing the E-CaP to move conformally with the skin. The possible movement domain associated with the limbs that are laminated with E-CaP can map the entire generated vector response (directional specific). The E-CaP is simulated and tested for mapping the directional sensitive epidermal movement.
- 20 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 42 (10) , 1456-1459
Solid Diffusion Based Micromachining-Free Transresistive Nanoelectromechanical ROM for High-Speed and Rugged Embedded Applications
We demonstrate a prototype of 1 kB high speed and scalable Nanoelectromechanical Read-Only-Memory (NEMS-ROM). The ROM cell current in fused-state is ~100 mA, and the average fused-state resistance is ~67 K${\Omega } $ (Logic ‘1’), whereas, in the open state (Logic ‘0’), it is$\sim \text{G}~{\Omega } $ . The fabrication of the NEMS-ROM involves the process of solid diffusion for the formation of the sub-nanometer coarse gap. The device fabrication is linearly scalable and is an etch-less process. The proposed NEMS-ROM is insensitive to thermal fluctuations (−100°C to +350 °C). The read delay of the NEMS-ROM unit cell is ~8.2 ps. NEMS-ROM core is suitable for storing the micro-operations for high-speed rugged embedded applications.- 20 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 42 (10) , 1456-1459
Solid Diffusion Based Micromachining-Free Transresistive Nanoelectromechanical ROM for High-Speed and Rugged Embedded Applications
We demonstrate a prototype of 1 kB high speed and scalable Nanoelectromechanical Read-Only-Memory (NEMS-ROM). The ROM cell current in fused-state is ~100 mA, and the average fused-state resistance is ~67 K${\Omega } $ (Logic ‘1’), whereas, in the open state (Logic ‘0’), it is$\sim \text{G}~{\Omega } $ . The fabrication of the NEMS-ROM involves the process of solid diffusion for the formation of the sub-nanometer coarse gap. The device fabrication is linearly scalable and is an etch-less process. The proposed NEMS-ROM is insensitive to thermal fluctuations (−100°C to +350 °C). The read delay of the NEMS-ROM unit cell is ~8.2 ps. NEMS-ROM core is suitable for storing the micro-operations for high-speed rugged embedded applications.- 17 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 30 (5) , 683-685
Piezoelectric Deactuation-Based Bi-Stable MEMS Switch: MEM-Z NVM
This letter proposes a bi-stable microelectromechanical impedance (MEM-Z) based non-volatile memory (NVM) element. The MEM-Z NVM cell has two stable impedance states. In context to bi-stable mechanical systems, the MEM-Z cell has a novel de-actuation mechanism. The MEM-Z shows ~20 times decrease in impedance from Off-state (logic-0) to On-state (logic-1). The letter also summarizes the fabrication and the design guidelines for the bi-stable MEM-Z NVM. Furthermore, the fabrication of the MEM-Z is important, because the bi-stability is the fine-play of locking of micro-ball ($\mu $ -ball) and micro-socket ($\mu $ -socket). The prototype bi-stable MEM-Z NVM is the first of its kind, and the reported fabrication is CMOS compatible. The device is tested in a vacuum for its operability and bi-stability. [2021-0135]- 17 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 30 (5) , 683-685
Piezoelectric Deactuation-Based Bi-Stable MEMS Switch: MEM-Z NVM
This letter proposes a bi-stable microelectromechanical impedance (MEM-Z) based non-volatile memory (NVM) element. The MEM-Z NVM cell has two stable impedance states. In context to bi-stable mechanical systems, the MEM-Z cell has a novel de-actuation mechanism. The MEM-Z shows ~20 times decrease in impedance from Off-state (logic-0) to On-state (logic-1). The letter also summarizes the fabrication and the design guidelines for the bi-stable MEM-Z NVM. Furthermore, the fabrication of the MEM-Z is important, because the bi-stability is the fine-play of locking of micro-ball ($\mu $ -ball) and micro-socket ($\mu $ -socket). The prototype bi-stable MEM-Z NVM is the first of its kind, and the reported fabrication is CMOS compatible. The device is tested in a vacuum for its operability and bi-stability. [2021-0135]- 29 April 2021
- Published by Springer Nature in Microsystem Technologies
- Vol. 27 (8) , 2925-2934
Maskless lithography: an approach to SU-8 based sensitive and high-g Z-axis polymer MEMS accelerometer
- 29 April 2021
- Published by Springer Nature in Microsystem Technologies
- Vol. 27 (8) , 2925-2934
Maskless lithography: an approach to SU-8 based sensitive and high-g Z-axis polymer MEMS accelerometer
- 22 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 30 (3) , 340-342
Highly Responsive Metal Oxide (V2O5)-Based NEMS Pirani Gauge for In-Situ Hermeticity Monitoring
The letter reports highly sensitive metal oxide (V 2 O 5 ) based NanoElectromechanical Systems (NEMS) Pirani gauge for pressure monitoring of a packaged device. The absence of additional supplementary material in the sensing element increases the sensing area and enables the in-situ monitoring capability. Considering the feasibility of the idea, the design is simulated and verified with the experimental results of the fabricated device. The device shows a sensitivity of 5.76 % per decade-Pa in the working range from 4 Pa to 2.7×10 3 Pa. The maximum average temperature of the sensing element is 48 °C at 4 Pa. It ensures corrosion-free operation and increases the lifetime of the device. The computed thermal response time of the device is ~500 ms at a power consumption of 285μW. [2020-0335]
- 22 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 30 (3) , 340-342
Highly Responsive Metal Oxide (V2O5)-Based NEMS Pirani Gauge for In-Situ Hermeticity Monitoring
The letter reports highly sensitive metal oxide (V 2 O 5 ) based NanoElectromechanical Systems (NEMS) Pirani gauge for pressure monitoring of a packaged device. The absence of additional supplementary material in the sensing element increases the sensing area and enables the in-situ monitoring capability. Considering the feasibility of the idea, the design is simulated and verified with the experimental results of the fabricated device. The device shows a sensitivity of 5.76 % per decade-Pa in the working range from 4 Pa to 2.7×10 3 Pa. The maximum average temperature of the sensing element is 48 °C at 4 Pa. It ensures corrosion-free operation and increases the lifetime of the device. The computed thermal response time of the device is ~500 ms at a power consumption of 285μW. [2020-0335]