Changes in intraocular pressure values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology tonometer (CST) in the early phase after small incision lenticule extraction (SMILE)
Open Access
- 18 November 2016
- journal article
- research article
- Published by Springer Nature in BMC Ophthalmology
- Vol. 16 (1) , 1-8
Abstract
Corneal biomechanical properties are always compromised after corneal refractive surgeries thus leading to underestimated intraocular pressure (IOP) that complicates the management of IOP. We investigated the changes in postoperative baseline of IOP values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology (CST) in the early phase after small incision lenticule extraction (SMILE). Twenty-two eyes (−6.76 ± 1.39D) of 22 moderate and high myopes, (28.36 ± 7.14 years, 12 male and 10 female) were involved in this prospective study. IOP values were measured using a non-contact tomometer (NCT-IOP), an ocular response analyzer (corneal-compensated IOP, IOPcc and Goldmann-correlated IOP, IOPg) and a Corvis scheimpflug technology tonometer (CST-IOP) preoperatively, at 20 min and 24 h, postoperatively. Repeated measures analysis of variance (RM-ANOVA), Pearson’s correlation analysis and multiple linear regression models (stepwise) were performed. Cut-off P values were 0.05. Except for IOPcc, NCT-IOP, IOPg, and CST-IOP values significantly decreased after SMILE procedure (All P values 0.05). Multiple linear regression models (stepwise) showed that the practical post-operative IOP value was the main predictor of the theoretical post-operative NCT-IOP, IOPcc and IOPg values (all P values <0.001). The postoperative applanation time 1 (AT1) value (B = 8.079, t = 4.866, P < 0.001), preoperative central corneal thickness (CCT) value (B = 0.035, t = 2.732, P = 0.014) and postoperative peak distance (PD) value (B = 0.515, t = 2.176, P = 0.043) were the main predictors of the theoretical post-operative CST-IOP value. IOP values are underestimated when assessed after SMILE by using NCT-IOP, IOPg and CST-IOP. The practical postoperative IOPcc value and theoretical post-operative CST-IOP value may be more preferable for IOP assessment in the early phase after SMILE. Current Controlled Trials ChiCTRONRC13003114 . Retrospectively registered 17 March 2013Keywords
Funding Information
- National Natural Science Foundation of China (81570879)
- Outstanding Academic Leaders Program of Shanghai Health System (XBR2013098)
- Liaoning Province Science and Technology Project (2013225303)
This publication has 29 references indexed in Scilit:
- Effects of Central Corneal Stromal Thickness and Epithelial Thickness on Intraocular Pressure Using Goldmann Applanation and Non-Contact TonometersPLOS ONE, 2016
- Interrelation of Hydration, Collagen Cross-Linking Treatment, and Biomechanical Properties of the CorneaCurrent Eye Research, 2015
- Differences in the Corneal Biomechanical Changes After SMILE and LASIKJournal of Refractive Surgery, 2014
- Changes in Corneal Deformation Parameters after Lenticule Creation and Extraction during Small Incision Lenticule Extraction (SMILE) ProcedurePLOS ONE, 2014
- Diagnosis of steroid-induced elevated intraocular pressure and associated lamellar keratitis after laser in situ keratomileusis using optical coherence tomographyJournal of Cataract & Refractive Surgery, 2009
- Biomechanical evidence of the distribution of cross-links in corneastreated with riboflavin and ultraviolet A lightJournal of Cataract & Refractive Surgery, 2006
- Effect of Corneal Curvature and Corneal Thickness on the Assessment of Intraocular Pressure Using Noncontact Tonometry in Patients After Myopic LASIK SurgeryCornea, 2006
- Determining in vivo biomechanical properties of the cornea with an ocular response analyzerJournal of Cataract & Refractive Surgery, 2005
- Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen.2002
- Über ApplanationstonometrieOphthalmologica, 1957