HMHuamao Miao

Huamao Miao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Huamao Miao has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Long-term observation of the in vivo safety of a new design of phakic refractive lens

    by Yinjie Jiang, Xun Chen, Mingrui Cheng, I-Chun Lin, Boliang Li, Xinjie Zhu, Guanghan Xu, Huamao Miao, Xiaoying Wang, Xingtao Zhou

    To evaluate the biosafety, reduction in anterior capsule opacification, and fluctuation in intraocular pressure (IOP) of a new phakic refractive lens (PRL) with a sinusoidal drainage groove design. This self-controlled experiment was performed on eight eyes of four rabbits. Each rabbit was implanted with a sinusoidal PRL (PRL-S5) in the right eye and a conventional posterior chamber PRL (PC-PRL) in the left eye. Slit-lamp examinations, optical coherence tomography, and IOP evaluation were performed before surgery and at 1 day, 1 week, 3 months, 6 months, and 1 year postoperatively in each eye. Gross examination, histopathology, and electron microscopy of the capsule and PRL were performed 1 year postoperatively. On slit-lamp examination, the inflammatory reactions recovered one week after surgery. The PC-PRL group developed anterior subcapsular cataracts at 3 months postoperatively and diffuse and dense opacification of the cortex at 1 year. PRL-S5 showed mild local opacification in the optical zone 6 months postoperatively, which did not progress significantly. At 1 year, PC-PRLs had greater opacification (27.37–72.17%) than PRL S5 (6.63–66.96%). Three months after surgery, one eye in the PC-PRL group had scleral staphyloma, one eye had corneal edema, and one eye experienced nasal hepatic prolapse into the anterior chamber. One eye in the PRL-S5 group had papillary membranes but recovered 6 months postoperatively. Histopathological examination revealed liquefaction and necrosis of the opacified area in the center of the subcapsular membrane in both groups. Numerous granular bodies and fibrous precipitates were observed in epithelial cells in the opaque area. Electron microscopy showed that epithelial cells proliferated on the surface of all anterior capsule membranes, with no significant differences between the two groups. The capsular PC-PRL group showed anterior cortical proliferation and fibrosis. An IOP elevation was noted on the first postoperative day (18.8 to 37.9 mmHg). However, both the PC-PRL and PRL-S5 groups exhibited relatively stable IOP levels 1 week, 3 months, 6 months, and 1 year postoperatively. The new PRL exhibited robust long-term biocompatibility. The sinusoidal groove design facilitated the maintenance of IOP stability without necessitating iridectomy and effectively mitigated the onset and progression of cataracts.

  • One-year analysis of the refractive stability, axial elongation and related factors in a high myopia population after Implantable Collamer Lens implantation

    by Xun Chen, Zhi Chen, Huamao Miao, Xuanqi Wang, Xiaoying Wang, Xingtao Zhou

    Purpose To investigate the refractive stability, axial length (AL) changes and their related factors in a high myopia population after Implantable Collamer Lens (ICL) implantation. Methods This prospective study included 116 eyes of 116 patients divided into several groups based on the spherical equivalent refractive error (SE)—SE > − 6 D, − 12 ≤ SE < − 6 D and SE < − 12 D groups—and AL—AL < 28 mm and AL ≥ 28 mm groups. The uncorrected and corrected distance visual acuity, refraction, AL and intraocular pressure were followed for 1 year. Results SE changed from − 11.53 ± 5.25 D preoperatively to − 0.33 ± 0.70 D at 1 week, and further changed to − 0.48 ± 0.77 D at 1 year after ICL implantation, with average progression being − 0.15 ± 0.37 D from 1 week to 1 year after surgery. AL changed from 27.95 ± 2.33 mm preoperatively to 27.98 ± 2.36 mm 1 year after surgery, with an average axial elongation of 0.03 ± 0.12 mm. The mean axial elongation rate was 0.05 mm/year in the SE < − 12 D group, being significantly faster than the other refractive groups (P < 0.05); it was 0.06 mm/year in the AL ≥ 28 mm group, being significantly faster than the AL < 28 mm group (P < 0.05). Conclusion Patients with high myopia and long AL showed a continuous myopic progression and axial elongation at an adult age one year after ICL surgery, especially in those with myopia higher than − 12.00 D and AL longer than 28.00 mm.


  • Open Access

    Safety and satisfaction of myopic small-incision lenticule extraction combined with monovision

    by Dan Fu, Li Zeng, Jing Zhao, Hua-Mao Miao, Zhi-Qiang Yu, Xing-Tao Zhou

    To investigate the safety and optical quality of small-incision lenticule extraction (SMILE) combined with monovision, and patient satisfaction with the procedure. The present study assessed a non-random case series involving 60 eyes of 30 patients (mean age 45.53 ± 3.20 years [range 41 to 52 years]) treated bilaterally using the VisuMax 500 system (Carl Zeiss Meditec, Jena, Germany) between January and July 2016. The target refraction was plano for the distance eye, and between − 0.5 and − 1.75 diopters (D) for the near eye. Visual acuity, refraction errors, ocular aberrations, and satisfaction questionnaire scores were calculated 1 year after surgery. All surgeries were uneventful, with a mean safety index of 1.03 and 1.04 in dominant and nondominant eyes, respectively. Binocular uncorrected distance visual acuity of all patients was ≥20/32, while binocular uncorrected near visual acuity was ≥20/40 1 year postoperatively. Higher-order aberration (0.45 ± 0.14, 0.51 ± 0.15 μm), spherical (0.18 ± 0.15, 0.21 ± 0.14 μm) and coma aberration (0.31 ± 0.16, 0.27 ± 0.17 μm) were identical between dominant and nondominant eyes after surgery. The overall satisfaction rate was 86.7% (26/30), with large contributions from age (OR = 1.76 95% CI: 1.03–2.53; P = 0.036). Binocular uncorrected distance visual acuity was related to preoperative spherical diopter (r = − 0.500; P = 0.005). Monovision appears to be a safe and effective option for myopia patients with presbyopia who are considering the SMILE procedure. Patients with younger age were more satisfied with the procedure.


  • Open Access

    Changes in intraocular pressure values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology tonometer (CST) in the early phase after small incision lenticule extraction (SMILE)

    by Yang Shen, Xiangjian Su, Xiu Liu, Huamao Miao, Xuejun Fang, Xingtao Zhou

    Corneal biomechanical properties are always compromised after corneal refractive surgeries thus leading to underestimated intraocular pressure (IOP) that complicates the management of IOP. We investigated the changes in postoperative baseline of IOP values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology (CST) in the early phase after small incision lenticule extraction (SMILE). Twenty-two eyes (−6.76 ± 1.39D) of 22 moderate and high myopes, (28.36 ± 7.14 years, 12 male and 10 female) were involved in this prospective study. IOP values were measured using a non-contact tomometer (NCT-IOP), an ocular response analyzer (corneal-compensated IOP, IOPcc and Goldmann-correlated IOP, IOPg) and a Corvis scheimpflug technology tonometer (CST-IOP) preoperatively, at 20 min and 24 h, postoperatively. Repeated measures analysis of variance (RM-ANOVA), Pearson’s correlation analysis and multiple linear regression models (stepwise) were performed. Cut-off P values were 0.05. Except for IOPcc, NCT-IOP, IOPg, and CST-IOP values significantly decreased after SMILE procedure (All P values 0.05). Multiple linear regression models (stepwise) showed that the practical post-operative IOP value was the main predictor of the theoretical post-operative NCT-IOP, IOPcc and IOPg values (all P values <0.001). The postoperative applanation time 1 (AT1) value (B = 8.079, t = 4.866, P < 0.001), preoperative central corneal thickness (CCT) value (B = 0.035, t = 2.732, P = 0.014) and postoperative peak distance (PD) value (B = 0.515, t = 2.176, P = 0.043) were the main predictors of the theoretical post-operative CST-IOP value. IOP values are underestimated when assessed after SMILE by using NCT-IOP, IOPg and CST-IOP. The practical postoperative IOPcc value and theoretical post-operative CST-IOP value may be more preferable for IOP assessment in the early phase after SMILE. Current Controlled Trials ChiCTRONRC13003114 . Retrospectively registered 17 March 2013


  • Open Access

    Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c)

    by Xun Chen, Huamao Miao, Rajeev Krishnan Naidu, Xiaoying Wang, Xingtao Zhou

    To objectively compare the early changes in vault over time following implantation of an Implantable Collamer Lens without (ICL V4) and with (ICL V4c) a central hole and the respective factors affecting vault change in moderate to high myopia. This prospective study comprised of 38 eyes of 38 patients implanted with ICL V4 and 39 eyes of 39 patients implanted with ICL V4c intraocular lenses. We quantitatively assessed the postoperative values of vault and pupil size at 1 day, 1 week, and 1 month following implantation using a rotating Scheimpflug camera (Pentacam). We compared these postoperative values within and between the two groups and identified the factors affecting vault change. The mean vaults at 1 day, 1 week, and 1 month following ICL V4 implantation were 303.68 ± 185.11, 517.89 ± 160.07 and 521.32 ± 155.72 μm respectively, and those following ICL V4c were 316.67 ± 186.89, 495.13 ± 180.84 and 510.77 ± 175.51 μm, respectively. There was a significant difference in vault between 1 day and 1 week postoperatively. There was a significant association between the vault change and the pupil size change in both groups from 1 day to 1 month postoperatively (Pearman correlation coefficient; ICL V4: r = 0.585, P = 0.001; ICL V4c: r = 0.588, P <0.001). The vault value 1 month after implantation of ICL V4 and ICL V4c was associated with the preoperative anterior chamber depth, horizontal corneal diameter, horizontal and vertical sulcus-to-sulcus. Pupil movement is a critical factor in vault change, with increasing vault observed postoperatively from 1 day to 1 week associated with the declining effects of pharmacological miosis and increasing pupil size. The anterior chamber depth, horizontal corneal diameter, horizontal and vertical sulcus-to-sulcus show some correlation with vault.


  • Open Access

    Enhancement of femtosecond lenticule extraction for visual symptomatic eye after myopia correction

    by Jing Zhao, Peijun Yao, Zhi Chen, Meiyan Li, Yang Shen, Huamao Miao, Xingtao Zhou

    The novel Femtosecond lenticule extraction (FLEx) procedure has been considered safe, predictable, and effective in treating myopia and myopic astigmatism, with few complications. However, an enhancement procedure after FLEx may be required in some cases, but has not been reported in detail.