XFXuejun Fang

Xuejun Fang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xuejun Fang has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparison of 1-Year Outcomes Between Small Incision Lenticule Extraction With Prophylactic Cross-Linking and Femtosecond Laser-Assisted In Situ Keratomileusis With Prophylactic Cross-Linking

    by Chunlei Liu, Zheng Wang, De Wu, Tian Luo, Yun Su, Junbai Mo, Xuejun Fang

    Purpose: To compare small incision lenticule extraction with prophylactic cross-linking (SMILE Xtra) and femtosecond laser-assisted in situ keratomileusis with prophylactic cross-linking (FS-LASIK Xtra) in their safety, efficacy, predictability, and stability. Methods: This is a prospective cohort study. Forty-eight eyes subjected to SMILE Xtra and 90 eyes subjected to FS-LASIK Xtra were enrolled. The enrolled eyes exhibited either borderline corneal topography or high myopia with thin cornea. The following parameters were evaluated before surgery and at 1 day; 1 week; and 1, 3, 6, and 12 months after surgery: corrected distance visual acuity, uncorrected distance visual acuity, manifest refractive spherical equivalent (MRSE), keratometry values, and thinnest corneal thickness. Results: After 1 month, no eye showed loss of 1 or more lines of corrected distance visual acuity. At 12 months, uncorrected distance visual acuity was 20/20 or better for 98% and 99% eyes in the SMILE Xtra and FS-LASIK Xtra groups, respectively (P = 0.657). For 93.8% eyes in the SMILE Xtra group and 90% eyes in the FS-LASIK Xtra group, the achieved MRSE was within ±0.50 diopter of the intended MRSE (P = 0.669). The correlation coefficients for predictability of MRSE correction by SMILE Xtra and FS-LASIK Xtra were 0.987 and 0.983, respectively. The mean MRSE values, keratometry values, and thinnest corneal thickness measured at the different time points showed no significant intra- or intergroup differences. Conclusions: Our evaluations of 1-year outcomes suggest that the safety, efficacy, predictability, and stability of SMILE Xtra are comparable with those of FS-LASIK Xtra.


  • Influence of Cap Thickness on Opaque Bubble Layer Formation in SMILE: 110 Versus 140 µm

    by De Wu, Bin Li, Min Huang, Xuejun Fang

    PURPOSE: To investigate the impact of cap thickness on the formation of an opaque bubble layer (OBL) during small incision lenticule extraction procedures. METHODS: In total, 100 eyes from 50 patients were prospectively examined. One of two corneal cap thicknesses was randomly assigned to each eye and differed in the contralateral eye: 110 µm in one eye and 140 µm in the other. OBL area and density were quantitatively assessed. RESULTS: The proportion of OBL areas in the anterior lenticule plane was 11.70% ± 7.35% in the 110-µm group, which was significantly higher than the 140-µm group (6.64% ± 4.68%, P < .001). For OBL areas located in the posterior lenticule plane, mean areas for the 110-µm group were also higher than those for the 140-µm group (1.32% ± 1.20% and 0.94% ± 0.59%, respectively; P = .002). Mean gray values of the OBL in the posterior lenticule plane were slightly different between the two groups ( P < .001), but no significant difference in OBL of the anterior lenticule plane was observed ( P = .055). Eyes with a 110-µm cap thickness had more focal OBLs, revealed by cap scanning (chi-square = 10.256, P = .001). CONCLUSIONS: Corneal cap thickness is predictive of opaque bubble layer during small incision lenticule extraction procedures. [ J Refract Surg . 2020;36(9):592–596.]


  • Influence of Cap Thickness on Corneal Curvature and Corneal Biomechanics After SMILE: A Prospective, Contralateral Eye Study

    by De Wu, Chunlei Liu, Bin Li, Diya Wang, Xuejun Fang

    PURPOSE: To evaluate the impact of cap thickness for small incision lenticule extraction (SMILE) on changes in corneal curvature and biomechanics. METHODS: One hundred eyes (50 patients) were enrolled in this prospective contralateral eye study. The difference in manifest refraction spherical equivalent (MRSE) in the same patient was less than 0.50 diopters. SMILE was performed with a randomized cap thickness of 110 µm in one eye and 140 µm in the other eye. MRSE, uncorrected distance visual acuity (UDVA), and corneal curvature and biomechanics were evaluated. The anterior and posterior surfaces of the corneal curvature (mean keratometry [Km] values 2, 4, and 6 mm from the pupil center) were measured by Pentacam HR (Oculus Optikgeräte, Wetzlar, Germany) and changes in corneal biomechanics at 6 months postoperatively by Scheimpflug technology. RESULTS: There was no significant between-group difference in UDVA or MRSE postoperatively. Postoperative changes in Km at the anterior surface (ΔKm-ant) in the 4-mm zone were significantly higher in the 110-µm group than in the 140-µm group at 1 day and 1, 3, and 6 months postoperatively ( P = .043, .045, .003, and .049, respectively); at 3 months, the ΔKm-ant in the 6-mm zone was higher in the 110-µm group ( P = .035). The changes in second appla-nation time, deformation amplitude, and integrated radius were significantly less in the 110-µm group ( P = .031, .049, and < .001, respectively). CONCLUSIONS: A thicker corneal cap caused less change in anterior surface curvature after SMILE for moderate or low myopia, with no significant difference in UDVA and MRSE. [ J Refract Surg . 2020;36(2):82–88.]


  • Short-term Observation of Intraocular Scattering and Bowman's Layer Microdistortions After SMILE-CCL

    by Huamao Miao, Xiu Liu, Mi Tian, Jing Zhao, Xuejun Fang, Xingtao Zhou

    PURPOSE: To investigate changes in intraocular scattering and Bowman's layer microdistortions after femtosecond laser small incision lenticule extraction using the continuous curvilinear lenticulerhexis technique (SMILE-CCL). METHODS: In this prospective study, 93 eyes of 93 patients (44 women, 49 men) were treated with SMILE-CCL. Mean age was 26.09 ± 4.39 years and mean spherical equivalent was −6.31 ± 2.16 diopters. The Objective Scatter Index (OSI) was examined with an objective optical quality analysis system. Bowman's layer microdistortions in the central 4-mm optical zone were measured using Fourier-domain optical coherence tomography. RESULTS: The mean OSI value increased from 0.67 preoperatively to 1.09 at 20 days, and then decreased to 0.84 at 3 months (P < .05). Microdistortions were observed in 62.37% of the eyes at 20 days and 48.39% at 3 months postoperatively (P < .05). The width of the microdistortions per meridian was 283.18 ± 197.19 μm at 20 days; this decreased to 156.00 ± 159.86 μm at 3 months (P < 0.05). Regression analysis models revealed that older age (b = 0.02, P = .03) and higher preoperative spherical equivalent (b = −0.09, P < .05) resulted in higher postoperative OSI values; no significant association was found between postoperative OSI values and microdistortion-related parameters (P > .05). Higher preoperative spherical equivalent (b = −0.28, P = .01) and thinner preoperative corneal thickness (b = −0.02, P = .01) were associated with more microdistortions. CONCLUSIONS: SMILE induced a temporary increase in OSI values and Bowman's layer microdistortions. The microdistortions did not influence intraocular scattering. [J Refract Surg. 2018;34(6):387–392.]


  • Open Access

    Changes in intraocular pressure values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology tonometer (CST) in the early phase after small incision lenticule extraction (SMILE)

    by Yang Shen, Xiangjian Su, Xiu Liu, Huamao Miao, Xuejun Fang, Xingtao Zhou

    Corneal biomechanical properties are always compromised after corneal refractive surgeries thus leading to underestimated intraocular pressure (IOP) that complicates the management of IOP. We investigated the changes in postoperative baseline of IOP values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology (CST) in the early phase after small incision lenticule extraction (SMILE). Twenty-two eyes (−6.76 ± 1.39D) of 22 moderate and high myopes, (28.36 ± 7.14 years, 12 male and 10 female) were involved in this prospective study. IOP values were measured using a non-contact tomometer (NCT-IOP), an ocular response analyzer (corneal-compensated IOP, IOPcc and Goldmann-correlated IOP, IOPg) and a Corvis scheimpflug technology tonometer (CST-IOP) preoperatively, at 20 min and 24 h, postoperatively. Repeated measures analysis of variance (RM-ANOVA), Pearson’s correlation analysis and multiple linear regression models (stepwise) were performed. Cut-off P values were 0.05. Except for IOPcc, NCT-IOP, IOPg, and CST-IOP values significantly decreased after SMILE procedure (All P values 0.05). Multiple linear regression models (stepwise) showed that the practical post-operative IOP value was the main predictor of the theoretical post-operative NCT-IOP, IOPcc and IOPg values (all P values <0.001). The postoperative applanation time 1 (AT1) value (B = 8.079, t = 4.866, P < 0.001), preoperative central corneal thickness (CCT) value (B = 0.035, t = 2.732, P = 0.014) and postoperative peak distance (PD) value (B = 0.515, t = 2.176, P = 0.043) were the main predictors of the theoretical post-operative CST-IOP value. IOP values are underestimated when assessed after SMILE by using NCT-IOP, IOPg and CST-IOP. The practical postoperative IOPcc value and theoretical post-operative CST-IOP value may be more preferable for IOP assessment in the early phase after SMILE. Current Controlled Trials ChiCTRONRC13003114 . Retrospectively registered 17 March 2013