Comparing Image Quality of Flat-Panel Chest Radiography with Storage Phosphor Radiography and Film-Screen Radiography
Authors:
- Marika GantenMGMarika Ganten
- Boris RadeleffBRBoris Radeleff
- Annette KampschulteAKAnnette Kampschulte
- Mark D. DanielsMDMark D. Daniels
- Günter W. KauffmannGKGünter W. Kauffmann
- Jochen HansmannJHJochen Hansmann
- 1 July 2003
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 181 (1) , 171-176
Abstract
OBJECTIVE. To evaluate image quality of a large-area direct-readout flat-panel detector system in chest radiography, we conducted an observer preference study. A clinical comparative study was conducted of the flat-panel system versus the storage phosphor and standard film-screen systems. MATERIALS AND METHODS. Routine chest radiographs (posteroanterior) of 30 patients that were obtained using flat-panel, storage phosphor, and film screen systems were compared. The visibility of 10 anatomic regions and the overall image quality criteria were rated independently by three radiologists using a 5-point scale. The significance of the differences in diagnostic performance was tested with a Wilcoxon's signed rank test. Dose measurements for the three modalities were performed. RESULTS. The flat-panel radiography system showed an improved visibility in most anatomic structures when compared with a state-of-the-art conventional film-screen system and an equal visibility when compared with a storage phosphor system. The flat-panel system showed the greatest enhancement in the depiction of small detailed structures (p < 0.05) and achieved this with a reduction in overall radiation dose of more than 50%. CONCLUSION. The visibility of anatomic structures provided by this flat-panel detector system is as good as if not better than that provided by conventional or storage phosphor systems while emitting a reduced radiation dose.Keywords
This publication has 13 references indexed in Scilit:
- Performance of a Flat-Panel Detector in Detecting Artificial Bone Lesions: Comparison with Conventional Screen-Film and Storage-Phosphor RadiographyRadiology, 2002
- Clinical Comparative Study with a Large-Area Amorphous Silicon Flat-Panel DetectorAmerican Journal of Roentgenology, 2002
- Digital Chest Radiography with a Selenium-Based Flat-Panel Detector Versus a Storage Phosphor SystemAmerican Journal of Roentgenology, 2000
- Chest Radiography With a Large-Area Detector Based on Cesium-Iodide/Amorphous-Silicon TechnologyJournal of Thoracic Imaging, 2000
- Performance of a 41×41‐cm amorphous silicon flat panel x‐ray detector for radiographic imaging applicationsMedical Physics, 2000
- Digital Radiography with a Large-Area, Amorphous-Silicon, Flat-Panel X-Ray Detector SystemInvestigative Radiology, 2000
- Comparison of low contrast detectability between a digital amorphous silicon and a screen‐film based imaging system for thoracic radiographyMedical Physics, 1999
- Principles of Digital Radiography with Large-Area, Electronically Readable Detectors: A Review of the BasicsRadiology, 1999
- Digitale Flachbilddetektortechnik basierend auf Cäsiumjodid und amorphem Silizium: Experimentelle Untersuchungen und erste klinische ErgebnisseRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1999
- Detection of Simulated Chest Lesions with Normal and Reduced Radiation DoseInvestigative Radiology, 1998