Multi-Channel, Actively Shielded, Power Efficient MRI Z-Gradient Cylindrical Coil Design Using Target-Field Method
Open Access
- 26 September 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 103840-103851
Abstract
Gradient coils are essential for MRI where fast and large electrical current pulses are typically applied to conventional, single-channel gradient coils, particularly for high-performance gradient applications. However, these pulses result in significant power losses and heating of the coil. We investigate the design of power-efficient multi-channel Z-gradient coils operating in the conventional mode comparing them to conventional single-channel coils designed using similar dimensions and alike DC performance characteristics. The power-efficiencies of thirteen different two-channel configurations having various section lengths for two different dimensions are analyzed. The current density of each section is approximated by Fourier series expansion where a linear equation relating the desired target field and current density is formulated and then solved. A stream function is derived from the obtained current density and then used to extract the final winding patterns of each section using a particular track width and a specific number of turns. The design process involves optimizing the current driving each channel, the distribution of coil windings, and the section size. Similarly, the performance of three-channel coils is also investigated. Results show that a power dissipation reduction of 17-28% and ~23% can be achieved using two- and three-channel coils, respectively. Moreover, we showed that multi-channel coils may have a slightly better shielding efficiency compared to conventional coils. A new methodology for designing two- and three-channel coils is presented where an advantage in terms of power efficiency can be gained depending on design parameters, coil’s dimensions, number of turns, and other metrics.Keywords
Funding Information
- African Biomedical Engineering Mobility (ABEM) for his Ph.D. program at Cairo University
- The ABEM project is funded by the Intra-Africa Academic Mobility Scheme of the Education, Audiovisual and Culture Executive Agency of European Commission
- Ph.D. program at Cairo University by the Yemeni ministry of higher education
This publication has 35 references indexed in Scilit:
- An optimized target-field method for MRI transverse biplanar gradient coil designMeasurement Science and Technology, 2011
- Magnetic field modeling with a set of individual localized coilsJournal of Magnetic Resonance, 2010
- A DIVERGENCE-FREE BEM METHOD TO MODEL QUASI-STATIC CURRENTS: APPLICATION TO MRI COIL DESIGNProgress In Electromagnetics Research B, 2010
- Diffusion Tensor MR Imaging and Fiber Tractography: Technical ConsiderationsAmerican Journal of Neuroradiology, 2008
- Diffusion Tensor MR Imaging and Fiber Tractography: Theoretic UnderpinningsAmerican Journal of Neuroradiology, 2008
- Target-field method for MRI biplanar gradient coil designJournal of Physics D: Applied Physics, 2007
- Gradient coil with active endcap shieldingConcepts in Magnetic Resonance Part B, 2007
- An inverse method for designing RF phased array coils in MRI—theoretical considerationsMeasurement Science and Technology, 2006
- A novel target-field method for magnetic resonance shim coils: III. Shielded zonal and tesseral coilsJournal of Physics D: Applied Physics, 2002
- Determining complicated winding patterns for shim coils using stream functions and the target‐field methodConcepts in Magnetic Resonance, 2001