Abdel-Monem M El-Sharkawy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abdel-Monem M El-Sharkawy has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed M. Badawi
Cairo Univ. (Egypt)
2 shared publications - Haile Baye Kassahun
Systems and Biomedical Engineering, Faculty of Engineering, Cairo University, Giza, Egypt
1 shared publication Sadeq S Alsharafi
Systems and Biomedical Engineering, Faculty of Engineering, Cairo University, Giza, Egypt
1 shared publication- Sadeq S. Alsharafi
Systems and Biomedical Engineering, Faculty of Engineering Cairo University Giza Egypt
1 shared publication
Latest Publications
- 19 July 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (5) , 2158-2174
Eddy currents analysis methods for an MRI longitudinal gradient coil
Purpose: The rapid switching of the gradient fields induces eddy currents in neighboring metallic structures, causing undesirable effects. Numerical computations are thus required to understand eddy‐currents effects for designing/implementing mitigation (involving passive shielding) and compensating techniques (using pre‐emphasis). Previously, the network‐analysis (NA) method was introduced to compute z‐gradient eddy currents, although limited to a circularly symmetric and unconnected coil. Multi‐layer integral method (MIM) method was recently introduced, modifying the circuit equation involving stream functions. We tailor MIM (TMIM) for a more general eddy‐currents analysis in thin structures. Z‐gradient eddy currents are analyzed and then compared using three methods (NA, TMIM, and Ansys). The analysis helps to evaluate the efficiency of passive shielding and to compensate eddy currents.Methods: NA and TMIM computational frameworks for harmonic and transient eddy‐currents analysis were implemented and cross‐validated against Ansys Maxwell. A pre‐emphasis pulse was modeled for compensating eddy currents.Results: Eddy‐currents analysis of an unconnected z‐gradient coil in both the passive shield and cryostat were computed, and results were comparable to the least computationally efficient Ansys simulations. Although NA computations are fast, TMIM is implemented with reasonable efficiency and applied to circularly unsymmetric geometries. TMIM computations were further validated against Ansys using a connected z‐gradient. Our computations allowed the effective evaluation of the performance of three various passive‐shielding configurations, non‐capped, capped, and slitted (for the first time), and an effective pre‐emphasis compensation model was computed.Conclusion: Three eddy‐currents analysis methods were studied and compared. Computationally efficient TMIM allows both harmonic and transient eddy‐currents analysis involving different/complex gradient configurations/situations as well as involved shielding structures. Eddy‐currents pre‐emphasis compensation was demonstrated.
- 19 July 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (5) , 2158-2174
Eddy currents analysis methods for an MRI longitudinal gradient coil
Purpose: The rapid switching of the gradient fields induces eddy currents in neighboring metallic structures, causing undesirable effects. Numerical computations are thus required to understand eddy‐currents effects for designing/implementing mitigation (involving passive shielding) and compensating techniques (using pre‐emphasis). Previously, the network‐analysis (NA) method was introduced to compute z‐gradient eddy currents, although limited to a circularly symmetric and unconnected coil. Multi‐layer integral method (MIM) method was recently introduced, modifying the circuit equation involving stream functions. We tailor MIM (TMIM) for a more general eddy‐currents analysis in thin structures. Z‐gradient eddy currents are analyzed and then compared using three methods (NA, TMIM, and Ansys). The analysis helps to evaluate the efficiency of passive shielding and to compensate eddy currents.Methods: NA and TMIM computational frameworks for harmonic and transient eddy‐currents analysis were implemented and cross‐validated against Ansys Maxwell. A pre‐emphasis pulse was modeled for compensating eddy currents.Results: Eddy‐currents analysis of an unconnected z‐gradient coil in both the passive shield and cryostat were computed, and results were comparable to the least computationally efficient Ansys simulations. Although NA computations are fast, TMIM is implemented with reasonable efficiency and applied to circularly unsymmetric geometries. TMIM computations were further validated against Ansys using a connected z‐gradient. Our computations allowed the effective evaluation of the performance of three various passive‐shielding configurations, non‐capped, capped, and slitted (for the first time), and an effective pre‐emphasis compensation model was computed.Conclusion: Three eddy‐currents analysis methods were studied and compared. Computationally efficient TMIM allows both harmonic and transient eddy‐currents analysis involving different/complex gradient configurations/situations as well as involved shielding structures. Eddy‐currents pre‐emphasis compensation was demonstrated.
- Open Access
- 26 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 103840-103851
Multi-Channel, Actively Shielded, Power Efficient MRI Z-Gradient Cylindrical Coil Design Using Target-Field Method
Gradient coils are essential for MRI where fast and large electrical current pulses are typically applied to conventional, single-channel gradient coils, particularly for high-performance gradient applications. However, these pulses result in significant power losses and heating of the coil. We investigate the design of power-efficient multi-channel Z-gradient coils operating in the conventional mode comparing them to conventional single-channel coils designed using similar dimensions and alike DC performance characteristics. The power-efficiencies of thirteen different two-channel configurations having various section lengths for two different dimensions are analyzed. The current density of each section is approximated by Fourier series expansion where a linear equation relating the desired target field and current density is formulated and then solved. A stream function is derived from the obtained current density and then used to extract the final winding patterns of each section using a particular track width and a specific number of turns. The design process involves optimizing the current driving each channel, the distribution of coil windings, and the section size. Similarly, the performance of three-channel coils is also investigated. Results show that a power dissipation reduction of 17-28% and ~23% can be achieved using two- and three-channel coils, respectively. Moreover, we showed that multi-channel coils may have a slightly better shielding efficiency compared to conventional coils. A new methodology for designing two- and three-channel coils is presented where an advantage in terms of power efficiency can be gained depending on design parameters, coil’s dimensions, number of turns, and other metrics.
- 26 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 103840-103851
Open AccessMulti-Channel, Actively Shielded, Power Efficient MRI Z-Gradient Cylindrical Coil Design Using Target-Field Method
Gradient coils are essential for MRI where fast and large electrical current pulses are typically applied to conventional, single-channel gradient coils, particularly for high-performance gradient applications. However, these pulses result in significant power losses and heating of the coil. We investigate the design of power-efficient multi-channel Z-gradient coils operating in the conventional mode comparing them to conventional single-channel coils designed using similar dimensions and alike DC performance characteristics. The power-efficiencies of thirteen different two-channel configurations having various section lengths for two different dimensions are analyzed. The current density of each section is approximated by Fourier series expansion where a linear equation relating the desired target field and current density is formulated and then solved. A stream function is derived from the obtained current density and then used to extract the final winding patterns of each section using a particular track width and a specific number of turns. The design process involves optimizing the current driving each channel, the distribution of coil windings, and the section size. Similarly, the performance of three-channel coils is also investigated. Results show that a power dissipation reduction of 17-28% and ~23% can be achieved using two- and three-channel coils, respectively. Moreover, we showed that multi-channel coils may have a slightly better shielding efficiency compared to conventional coils. A new methodology for designing two- and three-channel coils is presented where an advantage in terms of power efficiency can be gained depending on design parameters, coil’s dimensions, number of turns, and other metrics.