External beam radiotherapy is extensively used to treat cervical carcinomas. A single planning CT scan enables the calculation of the dose distribution. The treatment is delivered over 5 weeks. Large per-treatment anatomical variations may hamper the dose delivery, with the potential of an organs at risk (OAR) overdose and a tumor underdose. To anticipate these deformations, a recent approach proposed three planning CTs with variable bladder volumes, which had the limitation of not covering all per-treatment anatomical variations. An original patient-specific population-based library has been proposed. It consisted of generating two representative anatomies, in addition to the standard planning CT anatomy. First, the cervix and bladder meshes of a population of 20 patients (314 images) were registered to an anatomical template, using a deformable mesh registration. An iterative point-matching algorithm was developed based on local shape context (histogram of polar or cylindrical coordinates and geodesic distance to the base) and on a topology constraint filter. Second, a standard principal component analysis (PCA) model of the cervix and bladder was generated to extract the dominant deformation modes. Finally, specific deformations were obtained using posterior PCA models, with a constraint representing the top of the uterus deformation. For a new patient, the cervix-uterus and bladder were registered to the template, and the patient’s modeled planning library was built according to the model deformations. This method was applied following a leave-one-patient-out cross-validation. The performances of the modeled library were compared to those of the three-CT-based library and showing an improvement in both target coverage and OAR sparing.Keywords
Funding Information
- Agence Nationale de la Recherche (ANR-11-LABX-0004)
- Ligue Contre le Cancer
- French organization “La Vannetaise.”
This publication has 40 references indexed in Scilit:
- Individualized Nonadaptive and Online-Adaptive Intensity-Modulated Radiotherapy Treatment Strategies for Cervical Cancer Patients Based on Pretreatment Acquired Variable Bladder Filling Computed Tomography ScansInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- The thin plate spline robust point matching (TPS-RPM) algorithm: A revisitPattern Recognition Letters, 2011
- A population-based model to describe geometrical uncertainties in radiotherapy: applied to prostate casesPhysics in Medicine & Biology, 2011
- Motion and deformation of the target volumes during IMRT for cervical cancer: What margins do we need?Radiotherapy and Oncology, 2008
- 3D statistical models for tooth surface reconstructionComputers in Biology and Medicine, 2007
- Interfractional dose variation during intensity-modulated radiation therapy for cervical cancer assessed by weekly CT evaluationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Modelling individual geometric variation based on dominant eigenmodes of organ deformation: implementation and evaluationPhysics in Medicine & Biology, 2005
- A new point matching algorithm for non-rigid registrationComputer Vision and Image Understanding, 2003
- Shape matching and object recognition using shape contextsIEEE Transactions on Pattern Analysis and Machine Intelligence, 2002
- Elastic model-based segmentation of 3-D neuroradiological data setsIEEE Transactions on Medical Imaging, 1999