Bastien Rigaud
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bastien Rigaud has a total of 110 co-authors. Here are the top co-authors by number of shared publications:
Pascal Haigron
CLCC Eugène Marquis, University of Rennes, Inserm , Rennes , France
8 shared publications- Antoine Simon
LTSI, Universite de Rennes 1, Bât. 22, Campus de Beaulieu, Rennes, 35065, FRANCE
7 shared publications - Joel Castelli
University of Rennes, CLCC Eugène Marquis, Inserm, LTSI–UMR 1099, Rennes, France
7 shared publications Caroline Lafond
Univ Rennes
6 shared publications- Renaud de Crevoisier
Département de radiothérapie, centre régional de lutte contre le cancer Eugène-Marquis, 35042 Rennes, France
5 shared publications Antoine Simon
CLCC Eugène Marquis, University of Rennes, Inserm , Rennes , France
4 shared publications
Latest Publications
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Radiothérapie adaptative guidée par l’imagerie anatomique
Le traitement standard des cancers du col de l’utérus localement avancés repose sur une radiothérapie en parallèle à une chimiothérapie, suivie d’une curiethérapie. La radiothérapie externe comporte une phase de planification du traitement faite à partir d’une unique acquisition scanner et une phase de délivrance. Cependant, la position et la forme de la cible clinique varient fortement durant le traitement, avec des conséquences en termes de contrôle de la tumeur et de toxicité. L’objectif de cette thèse est donc de développer des stratégies optimisées de radiothérapie adaptative personnalisées permettant de prendre en compte et de compenser l’incidence de ces déformations anatomiques. Les images acquises lors de la planification et de la délivrance du traitement jouant alors un rôle central, ceci passe par le développement de méthodes de recalage, de fusion et d’analyse d’images ainsi que d’outils d’aide à la décision. Les travaux de thèse ont permis la définition de deux nouvelles stratégies de traitement : (1) une stratégie reposant sur une librairie évolutive permettant d’exploiter l’anatomie de la patiente en cours de traitement pour enrichir une librairie préexistante ; (2) une stratégie de librairie modélisée à partir d’un scanner de planification unique reposant sur l’analyse des déformations d’une population. Pour la mise en correspondance des anatomies des deux traitements par radiothérapie (avec et sans applicateur), une méthode de recalage déformable basée sur un modèle biomécanique est proposée et évaluée par rapport aux méthodes classiques et à un outil commercial. Les résultats, reposant notamment sur des critères géométriques, montrent que les approches proposées permettent d’assurer, pour toutes les patientes, une bonne couverture de la cible, tout en limitant l’irradiation des organes sains et donc, à terme, des meilleurs résultats cliniques.
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Radiothérapie adaptative guidée par l’imagerie anatomique
Le traitement standard des cancers du col de l’utérus localement avancés repose sur une radiothérapie en parallèle à une chimiothérapie, suivie d’une curiethérapie. La radiothérapie externe comporte une phase de planification du traitement faite à partir d’une unique acquisition scanner et une phase de délivrance. Cependant, la position et la forme de la cible clinique varient fortement durant le traitement, avec des conséquences en termes de contrôle de la tumeur et de toxicité. L’objectif de cette thèse est donc de développer des stratégies optimisées de radiothérapie adaptative personnalisées permettant de prendre en compte et de compenser l’incidence de ces déformations anatomiques. Les images acquises lors de la planification et de la délivrance du traitement jouant alors un rôle central, ceci passe par le développement de méthodes de recalage, de fusion et d’analyse d’images ainsi que d’outils d’aide à la décision. Les travaux de thèse ont permis la définition de deux nouvelles stratégies de traitement : (1) une stratégie reposant sur une librairie évolutive permettant d’exploiter l’anatomie de la patiente en cours de traitement pour enrichir une librairie préexistante ; (2) une stratégie de librairie modélisée à partir d’un scanner de planification unique reposant sur l’analyse des déformations d’une population. Pour la mise en correspondance des anatomies des deux traitements par radiothérapie (avec et sans applicateur), une méthode de recalage déformable basée sur un modèle biomécanique est proposée et évaluée par rapport aux méthodes classiques et à un outil commercial. Les résultats, reposant notamment sur des critères géométriques, montrent que les approches proposées permettent d’assurer, pour toutes les patientes, une bonne couverture de la cible, tout en limitant l’irradiation des organes sains et donc, à terme, des meilleurs résultats cliniques.
- Open Access
- 25 May 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (8) , e13991
Contour‐guided deep learning based deformable image registration for dose monitoring during CBCT‐guided radiotherapy of prostate cancer
Purpose: To evaluate deep learning (DL)‐based deformable image registration (DIR) for dose accumulation during radiotherapy of prostate cancer patients.Methods and Materials: Data including 341 CBCTs (209 daily, 132 weekly) and 23 planning CTs from 23 patients was retrospectively analyzed. Anatomical deformation during treatment was estimated using free‐form deformation (FFD) method from Elastix and DL‐based VoxelMorph approaches. The VoxelMorph method was investigated using anatomical scans (VMorph_Sc) or label images (VMorph_Msk), or the combination of both (VMorph_Sc_Msk). Accumulated doses were compared with the planning dose.Results: The DSC ranges, averaged for prostate, rectum and bladder, were 0.60–0.71, 0.67–0.79, 0.93–0.98, and 0.89–0.96 for the FFD, VMorph_Sc, VMorph_Msk, and VMorph_Sc_Msk methods, respectively. When including both anatomical and label images, VoxelMorph estimated more complex deformations resulting in heterogeneous determinant of Jacobian and higher percentage of deformation vector field (DVF) folding (up to a mean value of 1.90% in the prostate). Large differences were observed between DL‐based methods regarding estimation of the accumulated dose, showing systematic overdosage and underdosage of the bladder and rectum, respectively. The difference between planned mean dose and accumulated mean dose with VMorph_Sc_Msk reached a median value of +6.3 Gy for the bladder and −5.1 Gy for the rectum.Conclusion: The estimation of the deformations using DL‐based approach is feasible for male pelvic anatomy but requires the inclusion of anatomical contours to improve organ correspondence. High variability in the estimation of the accumulated dose depending on the deformable strategy suggests further investigation of DL‐based techniques before clinical deployment.
- 25 May 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (8) , e13991
Open AccessContour‐guided deep learning based deformable image registration for dose monitoring during CBCT‐guided radiotherapy of prostate cancer
Purpose: To evaluate deep learning (DL)‐based deformable image registration (DIR) for dose accumulation during radiotherapy of prostate cancer patients.Methods and Materials: Data including 341 CBCTs (209 daily, 132 weekly) and 23 planning CTs from 23 patients was retrospectively analyzed. Anatomical deformation during treatment was estimated using free‐form deformation (FFD) method from Elastix and DL‐based VoxelMorph approaches. The VoxelMorph method was investigated using anatomical scans (VMorph_Sc) or label images (VMorph_Msk), or the combination of both (VMorph_Sc_Msk). Accumulated doses were compared with the planning dose.Results: The DSC ranges, averaged for prostate, rectum and bladder, were 0.60–0.71, 0.67–0.79, 0.93–0.98, and 0.89–0.96 for the FFD, VMorph_Sc, VMorph_Msk, and VMorph_Sc_Msk methods, respectively. When including both anatomical and label images, VoxelMorph estimated more complex deformations resulting in heterogeneous determinant of Jacobian and higher percentage of deformation vector field (DVF) folding (up to a mean value of 1.90% in the prostate). Large differences were observed between DL‐based methods regarding estimation of the accumulated dose, showing systematic overdosage and underdosage of the bladder and rectum, respectively. The difference between planned mean dose and accumulated mean dose with VMorph_Sc_Msk reached a median value of +6.3 Gy for the bladder and −5.1 Gy for the rectum.Conclusion: The estimation of the deformations using DL‐based approach is feasible for male pelvic anatomy but requires the inclusion of anatomical contours to improve organ correspondence. High variability in the estimation of the accumulated dose depending on the deformable strategy suggests further investigation of DL‐based techniques before clinical deployment.
- 1 April 2023
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 307 (2) , e221373
Ablative Margins of Colorectal Liver Metastases Using Deformable CT Image Registration and Autosegmentation
Ablative margin quantified using biomechanical deformable CT image registration with artificial intelligence–based autosegmentation was strongly associated and spatially localized within local dise... Background Confirming ablation completeness with sufficient ablative margin is critical for local tumor control following colorectal liver metastasis (CLM) ablation. An image-based confirmation met...
- 1 April 2023
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 307 (2) , e221373
Ablative Margins of Colorectal Liver Metastases Using Deformable CT Image Registration and Autosegmentation
Ablative margin quantified using biomechanical deformable CT image registration with artificial intelligence–based autosegmentation was strongly associated and spatially localized within local dise... Background Confirming ablation completeness with sufficient ablative margin is critical for local tumor control following colorectal liver metastasis (CLM) ablation. An image-based confirmation met...
- 15 December 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (24) , 245020
Automatic segmentation for plan-of-the-day selection in CBCT-guided adaptive radiation therapy of cervical cancer
Objective. Plan-of-the-day (PoD) adaptive radiation therapy (ART) is based on a library of treatment plans, among which, at each treatment fraction, the PoD is selected using daily images. However, this strategy is limited by PoD selection uncertainties. This work aimed to propose and evaluate a workflow to automatically and quantitatively identify the PoD for cervix cancer ART based on daily CBCT images. Approach. The quantification was based on the segmentation of the main structures of interest in the CBCT images (clinical target volume [CTV], rectum, bladder, and bowel bag) using a deep learning model. Then, the PoD was selected from the treatment plan library according to the geometrical coverage of the CTV. For the evaluation, the resulting PoD was compared to the one obtained considering reference CBCT delineations. Main results. In experiments on a database of 23 patients with 272 CBCT images, the proposed method obtained an agreement between the reference PoD and the automatically identified PoD for 91.5% of treatment fractions (99.6% when considering a 5% margin on CTV coverage). Significance. The proposed automatic workflow automatically selected PoD for ART using deep-learning methods. The results showed the ability of the proposed process to identify the optimal PoD in a treatment plan library.
- 15 December 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (24) , 245020
Automatic segmentation for plan-of-the-day selection in CBCT-guided adaptive radiation therapy of cervical cancer
Objective. Plan-of-the-day (PoD) adaptive radiation therapy (ART) is based on a library of treatment plans, among which, at each treatment fraction, the PoD is selected using daily images. However, this strategy is limited by PoD selection uncertainties. This work aimed to propose and evaluate a workflow to automatically and quantitatively identify the PoD for cervix cancer ART based on daily CBCT images. Approach. The quantification was based on the segmentation of the main structures of interest in the CBCT images (clinical target volume [CTV], rectum, bladder, and bowel bag) using a deep learning model. Then, the PoD was selected from the treatment plan library according to the geometrical coverage of the CTV. For the evaluation, the resulting PoD was compared to the one obtained considering reference CBCT delineations. Main results. In experiments on a database of 23 patients with 272 CBCT images, the proposed method obtained an agreement between the reference PoD and the automatically identified PoD for 91.5% of treatment fractions (99.6% when considering a 5% margin on CTV coverage). Significance. The proposed automatic workflow automatically selected PoD for ART using deep-learning methods. The results showed the ability of the proposed process to identify the optimal PoD in a treatment plan library.
- Open Access
Deep Learning Models for Automated Assessment of Breast Density Using Multiple Mammographic Image Types
Recently, convolutional neural network (CNN) models have been proposed to automate the assessment of breast density, breast cancer detection or risk stratification using single image modality. However, analysis of breast density using multiple mammographic types using clinical data has not been reported in the literature. In this study, we investigate pre-trained EfficientNetB0 deep learning (DL) models for automated assessment of breast density using multiple mammographic types with and without clinical information to improve reliability and versatility of reporting. 120,000 for-processing and for-presentation full-field digital mammograms (FFDM), digital breast tomosynthesis (DBT), and synthesized 2D images from 5032 women were retrospectively analyzed. Each participant underwent up to 3 screening examinations and completed a questionnaire at each screening encounter. Pre-trained EfficientNetB0 DL models with or without clinical history were optimized. The DL models were evaluated using BI-RADS (fatty, scattered fibroglandular densities, heterogeneously dense, or extremely dense) versus binary (non-dense or dense) density classification. Pre-trained EfficientNetB0 model performances were compared using inter-observer and commercial software (Volpara) variabilities. Results show that the average Fleiss’ Kappa score between-observers ranged from 0.31–0.50 and 0.55–0.69 for the BI-RADS and binary classifications, respectively, showing higher uncertainty among experts. Volpara-observer agreement was 0.33 and 0.54 for BI-RADS and binary classifications, respectively, showing fair to moderate agreement. However, our proposed pre-trained EfficientNetB0 DL models-observer agreement was 0.61–0.66 and 0.70–0.75 for BI-RADS and binary classifications, respectively, showing moderate to substantial agreement. Overall results show that the best breast density estimation was achieved using for-presentation FFDM and DBT images without added clinical information. Pre-trained EfficientNetB0 model can automatically assess breast density from any images modality type, with the best results obtained from for-presentation FFDM and DBT, which are the most common image archived in clinical practice.
Open AccessDeep Learning Models for Automated Assessment of Breast Density Using Multiple Mammographic Image Types
Recently, convolutional neural network (CNN) models have been proposed to automate the assessment of breast density, breast cancer detection or risk stratification using single image modality. However, analysis of breast density using multiple mammographic types using clinical data has not been reported in the literature. In this study, we investigate pre-trained EfficientNetB0 deep learning (DL) models for automated assessment of breast density using multiple mammographic types with and without clinical information to improve reliability and versatility of reporting. 120,000 for-processing and for-presentation full-field digital mammograms (FFDM), digital breast tomosynthesis (DBT), and synthesized 2D images from 5032 women were retrospectively analyzed. Each participant underwent up to 3 screening examinations and completed a questionnaire at each screening encounter. Pre-trained EfficientNetB0 DL models with or without clinical history were optimized. The DL models were evaluated using BI-RADS (fatty, scattered fibroglandular densities, heterogeneously dense, or extremely dense) versus binary (non-dense or dense) density classification. Pre-trained EfficientNetB0 model performances were compared using inter-observer and commercial software (Volpara) variabilities. Results show that the average Fleiss’ Kappa score between-observers ranged from 0.31–0.50 and 0.55–0.69 for the BI-RADS and binary classifications, respectively, showing higher uncertainty among experts. Volpara-observer agreement was 0.33 and 0.54 for BI-RADS and binary classifications, respectively, showing fair to moderate agreement. However, our proposed pre-trained EfficientNetB0 DL models-observer agreement was 0.61–0.66 and 0.70–0.75 for BI-RADS and binary classifications, respectively, showing moderate to substantial agreement. Overall results show that the best breast density estimation was achieved using for-presentation FFDM and DBT images without added clinical information. Pre-trained EfficientNetB0 model can automatically assess breast density from any images modality type, with the best results obtained from for-presentation FFDM and DBT, which are the most common image archived in clinical practice.
- Open Access
Black bone MRI morphometry for mandibular cortical bone measurement in head and neck cancer patients: Prospective method comparison with CT
Objectives: To determine the utility of low-flip angle “black bone” magnetic resonance imaging (MRI) for cortical mandibular bone assessment by comparing interdentium cortical measurements and inter-observer morphometric variability in relation to computed tomography (CT). Methods: Quantification of cortical mandible bone width was performed as per Hamada et al. at 15 cross-sectional interdentium locations on pre-treatment black bone MRI and CT for 15 oropharyngeal cancer patients, with inter-observer analyses on a subset of 3 patients by 11 observers. Bland-Altman limits of agreement and bias estimation, Lin’s concordance correlation (LCC), and Deming orthogonal regression were used to compare CT and MRI measurements. The absolute variance and intraclass correlation coefficient (ICC) were implemented for the inter-observer error quantification. Results: Both the Bland Altman and Deming regression analyses showed CT and black bone MRI measurements were comparable within ±0.85 mm limits of agreement, and systematically smaller for MRI. LCC (0.60[0.52;0.67]) showed moderate equivalence between modalities. The average absolute variance between the observers was similar on CT (1.13±0.06 mm) and MRI (1.15 ±0.06 mm). The ICC analyses showed that measurement consistency was significantly higher (p<0.001) for the black bone MRI (0.43[0.32;0.56]) than CT (0.22[0.13;0.35]); nonetheless, the ICC was poor for both modalities. Conclusions: Black bone MR sequence is usable as an alternative to CT for cortical mandible bone measurements, allowing use for early detection of cortical alteration (e.g. osteonecrosis). The cortical bone measurements showed substantive but equivalent inter-observer variation on both CT and black bone MRI. (Semi)automated measurement may mitigate this in future work.
Open AccessBlack bone MRI morphometry for mandibular cortical bone measurement in head and neck cancer patients: Prospective method comparison with CT
Objectives: To determine the utility of low-flip angle “black bone” magnetic resonance imaging (MRI) for cortical mandibular bone assessment by comparing interdentium cortical measurements and inter-observer morphometric variability in relation to computed tomography (CT). Methods: Quantification of cortical mandible bone width was performed as per Hamada et al. at 15 cross-sectional interdentium locations on pre-treatment black bone MRI and CT for 15 oropharyngeal cancer patients, with inter-observer analyses on a subset of 3 patients by 11 observers. Bland-Altman limits of agreement and bias estimation, Lin’s concordance correlation (LCC), and Deming orthogonal regression were used to compare CT and MRI measurements. The absolute variance and intraclass correlation coefficient (ICC) were implemented for the inter-observer error quantification. Results: Both the Bland Altman and Deming regression analyses showed CT and black bone MRI measurements were comparable within ±0.85 mm limits of agreement, and systematically smaller for MRI. LCC (0.60[0.52;0.67]) showed moderate equivalence between modalities. The average absolute variance between the observers was similar on CT (1.13±0.06 mm) and MRI (1.15 ±0.06 mm). The ICC analyses showed that measurement consistency was significantly higher (p<0.001) for the black bone MRI (0.43[0.32;0.56]) than CT (0.22[0.13;0.35]); nonetheless, the ICC was poor for both modalities. Conclusions: Black bone MR sequence is usable as an alternative to CT for cortical mandible bone measurements, allowing use for early detection of cortical alteration (e.g. osteonecrosis). The cortical bone measurements showed substantive but equivalent inter-observer variation on both CT and black bone MRI. (Semi)automated measurement may mitigate this in future work.
- 1 September 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (17) , 175018
Biomechanical modeling of neck flexion for deformable alignment of the salivary glands in head and neck cancer images
During head and neck (HN) cancer radiation therapy, analysis of the dose-response relationship for the parotid glands (PG) relies on the ability to accurately align soft tissue organs between longitudinal images. In order to isolate the response of the salivary glands to delivered dose, from deformation due to patient position, it is important to resolve the patient postural changes, mainly due to neck flexion. In this study we evaluate the use of a biomechanical model-based deformable image registration (DIR) algorithm to estimate the displacements and deformations of the salivary glands due to postural changes. A total of 82 pairs of CT images of HN cancer patients with varying angles of neck flexion were retrospectively obtained. The pairs of CTs of each patient were aligned using bone-based rigid registration. The images were then deformed using biomechanical model-based DIR method that focused on the mandible, C1 vertebrae, C3 vertebrae, and external contour. For comparison, an intensity-based DIR was also performed. The accuracy of the biomechanical model-based DIR was assessed using Dice similarity coefficient (DSC) for all images and for the subset of images where the PGs had a volume change within 20%. The accuracy was compared to the intensity-based DIR. The PG mean ± STD DSC were 0.63 ± 0.18, 0.80 ± 0.08, and 0.82 ± 0.15 for the rigid registration, biomechanical model-based DIR, and intensity based DIR, respectively, for patients with a PG volume change up to 20%. For the entire cohort of patients, where the PG volume change was up to 57%, the PG mean ± STD DSC were 0.60 ± 0.18, 0.78 ± 0.09, and 0.81 ± 0.14 for the rigid registration, biomechanical model-based DIR, and intensity based DIR, respectively. The difference in DSC of the intensity and biomechanical model-based DIR methods was not statistically significant when the volume change was less than 20% (two-sided paired t -test, p = 0.12). When all volume changes were considered, there was a significant difference between the two registration approaches, although the magnitude was small. These results demonstrate that the proposed biomechanical model with boundary conditions on the bony anatomy can serve to describe the varying angles of neck flexion appearing in images during radiation treatment and to align the salivary glands for proper analysis of dose-response relationships. It also motivates the need for dose response modeling following neck flexion for cases where parotid gland response is noted.
- 1 September 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (17) , 175018
Biomechanical modeling of neck flexion for deformable alignment of the salivary glands in head and neck cancer images
During head and neck (HN) cancer radiation therapy, analysis of the dose-response relationship for the parotid glands (PG) relies on the ability to accurately align soft tissue organs between longitudinal images. In order to isolate the response of the salivary glands to delivered dose, from deformation due to patient position, it is important to resolve the patient postural changes, mainly due to neck flexion. In this study we evaluate the use of a biomechanical model-based deformable image registration (DIR) algorithm to estimate the displacements and deformations of the salivary glands due to postural changes. A total of 82 pairs of CT images of HN cancer patients with varying angles of neck flexion were retrospectively obtained. The pairs of CTs of each patient were aligned using bone-based rigid registration. The images were then deformed using biomechanical model-based DIR method that focused on the mandible, C1 vertebrae, C3 vertebrae, and external contour. For comparison, an intensity-based DIR was also performed. The accuracy of the biomechanical model-based DIR was assessed using Dice similarity coefficient (DSC) for all images and for the subset of images where the PGs had a volume change within 20%. The accuracy was compared to the intensity-based DIR. The PG mean ± STD DSC were 0.63 ± 0.18, 0.80 ± 0.08, and 0.82 ± 0.15 for the rigid registration, biomechanical model-based DIR, and intensity based DIR, respectively, for patients with a PG volume change up to 20%. For the entire cohort of patients, where the PG volume change was up to 57%, the PG mean ± STD DSC were 0.60 ± 0.18, 0.78 ± 0.09, and 0.81 ± 0.14 for the rigid registration, biomechanical model-based DIR, and intensity based DIR, respectively. The difference in DSC of the intensity and biomechanical model-based DIR methods was not statistically significant when the volume change was less than 20% (two-sided paired t -test, p = 0.12). When all volume changes were considered, there was a significant difference between the two registration approaches, although the magnitude was small. These results demonstrate that the proposed biomechanical model with boundary conditions on the bony anatomy can serve to describe the varying angles of neck flexion appearing in images during radiation treatment and to align the salivary glands for proper analysis of dose-response relationships. It also motivates the need for dose response modeling following neck flexion for cases where parotid gland response is noted.
- 3 June 2019
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 58 (9) , 1225-1237
Deformable image registration for radiation therapy: principle, methods, applications and evaluation
Background: Deformable image registration (DIR) is increasingly used in the field of radiation therapy (RT) to account for anatomical deformations. The aims of this paper are to describe the main applications of DIR in RT and discuss current DIR evaluation methods. Methods: Articles on DIR published from January 2000 to October 2018 were extracted from PubMed and Science Direct. Our search was restricted to articles that report data obtained from humans, were written in English, and address DIR methods for RT. A total of 207 articles were selected from among 2506 identified in the search process. Results: At planning, DIR is used for organ delineation using atlas-based segmentation, deformation-based planning target volume definition, functional planning and magnetic resonance imaging-based dose calculation. In image-guided RT, DIR is used for contour propagation and dose calculation on per-treatment imaging. DIR is also used to determine the accumulated dose from fraction to fraction in external beam RT and brachytherapy, both for dose reporting and adaptive RT. In the case of re-irradiation, DIR can be used to estimate the cumulated dose of the two irradiations. Finally, DIR can be used to predict toxicity in voxel-wise population analysis. However, the evaluation of DIR remains an open issue, especially when dealing with complex cases such as the disappearance of matter. To quantify DIR uncertainties, most evaluation methods are limited to geometry-based metrics. Software companies have now integrated DIR tools into treatment planning systems for clinical use, such as contour propagation and fraction dose accumulation. Conclusions: DIR is increasingly important in RT applications, from planning to toxicity prediction. DIR is routinely used to reduce the workload of contour propagation. However, its use for complex dosimetric applications must be carefully evaluated by combining quantitative and qualitative analyses.
- 3 June 2019
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 58 (9) , 1225-1237
Deformable image registration for radiation therapy: principle, methods, applications and evaluation
Background: Deformable image registration (DIR) is increasingly used in the field of radiation therapy (RT) to account for anatomical deformations. The aims of this paper are to describe the main applications of DIR in RT and discuss current DIR evaluation methods. Methods: Articles on DIR published from January 2000 to October 2018 were extracted from PubMed and Science Direct. Our search was restricted to articles that report data obtained from humans, were written in English, and address DIR methods for RT. A total of 207 articles were selected from among 2506 identified in the search process. Results: At planning, DIR is used for organ delineation using atlas-based segmentation, deformation-based planning target volume definition, functional planning and magnetic resonance imaging-based dose calculation. In image-guided RT, DIR is used for contour propagation and dose calculation on per-treatment imaging. DIR is also used to determine the accumulated dose from fraction to fraction in external beam RT and brachytherapy, both for dose reporting and adaptive RT. In the case of re-irradiation, DIR can be used to estimate the cumulated dose of the two irradiations. Finally, DIR can be used to predict toxicity in voxel-wise population analysis. However, the evaluation of DIR remains an open issue, especially when dealing with complex cases such as the disappearance of matter. To quantify DIR uncertainties, most evaluation methods are limited to geometry-based metrics. Software companies have now integrated DIR tools into treatment planning systems for clinical use, such as contour propagation and fraction dose accumulation. Conclusions: DIR is increasingly important in RT applications, from planning to toxicity prediction. DIR is routinely used to reduce the workload of contour propagation. However, its use for complex dosimetric applications must be carefully evaluated by combining quantitative and qualitative analyses.
- 31 May 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (11) , 115023
Deformable image registration for dose mapping between external beam radiotherapy and brachytherapy images of cervical cancer
For locally advanced cervical cancer (LACC), anatomy correspondence with and without BT applicator needs to be quantified to merge the delivered doses of external beam radiation therapy (EBRT) and brachytherapy (BT). This study proposed and evaluated different deformable image registration (DIR) methods for this application. Twenty patients who underwent EBRT and BT for LACC were retrospectively analyzed. Each patient had a pre-BT CT at EBRT boost (without applicator) and a CT and MRI at BT (with applicator). The evaluated DIR methods were the diffeomorphic Demons, commercial intensity and hybrid methods, and three different biomechanical models. The biomechanical models considered different boundary conditions (BCs). The impact of the BT devices insertion on the anatomy was quantified. DIR method performances were quantified using geometric criteria between the original and deformed contours. The BT dose was deformed toward the pre-CT BT by each DIR method. The impact of boundary conditions to drive the biomechanical model was evaluated based on the deformation vector field and dose differences. The GEC-ESTRO guideline dose indices were reported. Large organ displacements, deformations, and volume variations were observed between the pre-BT and BT anatomies. Rigid registration and intensity-based DIR resulted in poor geometric accuracy with mean Dice similarity coefficient (DSC) inferior to 0.57, 0.63, 0.42, 0.32, and 0.43 for the rectum, bladder, vagina, cervix and uterus, respectively. Biomechanical models provided a mean DSC of 0.96 for all the organs. By considering the cervix-uterus as one single structure, biomechanical models provided a mean DSC of 0.88 and 0.94 for the cervix and uterus, respectively. The deformed doses were represented for each DIR method. Caution should be used when performing DIR for this application as standard techniques may have unacceptable results. The biomechanical model with the cervix-uterus as one structure provided the most realistic deformations to propagate the BT dose toward the EBRT boost anatomy.
- 31 May 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (11) , 115023
Deformable image registration for dose mapping between external beam radiotherapy and brachytherapy images of cervical cancer
For locally advanced cervical cancer (LACC), anatomy correspondence with and without BT applicator needs to be quantified to merge the delivered doses of external beam radiation therapy (EBRT) and brachytherapy (BT). This study proposed and evaluated different deformable image registration (DIR) methods for this application. Twenty patients who underwent EBRT and BT for LACC were retrospectively analyzed. Each patient had a pre-BT CT at EBRT boost (without applicator) and a CT and MRI at BT (with applicator). The evaluated DIR methods were the diffeomorphic Demons, commercial intensity and hybrid methods, and three different biomechanical models. The biomechanical models considered different boundary conditions (BCs). The impact of the BT devices insertion on the anatomy was quantified. DIR method performances were quantified using geometric criteria between the original and deformed contours. The BT dose was deformed toward the pre-CT BT by each DIR method. The impact of boundary conditions to drive the biomechanical model was evaluated based on the deformation vector field and dose differences. The GEC-ESTRO guideline dose indices were reported. Large organ displacements, deformations, and volume variations were observed between the pre-BT and BT anatomies. Rigid registration and intensity-based DIR resulted in poor geometric accuracy with mean Dice similarity coefficient (DSC) inferior to 0.57, 0.63, 0.42, 0.32, and 0.43 for the rectum, bladder, vagina, cervix and uterus, respectively. Biomechanical models provided a mean DSC of 0.96 for all the organs. By considering the cervix-uterus as one single structure, biomechanical models provided a mean DSC of 0.88 and 0.94 for the cervix and uterus, respectively. The deformed doses were represented for each DIR method. Caution should be used when performing DIR for this application as standard techniques may have unacceptable results. The biomechanical model with the cervix-uterus as one structure provided the most realistic deformations to propagate the BT dose toward the EBRT boost anatomy.
- 16 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 38 (2) , 406-416
Statistical Shape Model to Generate a Planning Library for Cervical Adaptive Radiotherapy
External beam radiotherapy is extensively used to treat cervical carcinomas. A single planning CT scan enables the calculation of the dose distribution. The treatment is delivered over 5 weeks. Large per-treatment anatomical variations may hamper the dose delivery, with the potential of an organs at risk (OAR) overdose and a tumor underdose. To anticipate these deformations, a recent approach proposed three planning CTs with variable bladder volumes, which had the limitation of not covering all per-treatment anatomical variations. An original patient-specific population-based library has been proposed. It consisted of generating two representative anatomies, in addition to the standard planning CT anatomy. First, the cervix and bladder meshes of a population of 20 patients (314 images) were registered to an anatomical template, using a deformable mesh registration. An iterative point-matching algorithm was developed based on local shape context (histogram of polar or cylindrical coordinates and geodesic distance to the base) and on a topology constraint filter. Second, a standard principal component analysis (PCA) model of the cervix and bladder was generated to extract the dominant deformation modes. Finally, specific deformations were obtained using posterior PCA models, with a constraint representing the top of the uterus deformation. For a new patient, the cervix-uterus and bladder were registered to the template, and the patient’s modeled planning library was built according to the model deformations. This method was applied following a leave-one-patient-out cross-validation. The performances of the modeled library were compared to those of the three-CT-based library and showing an improvement in both target coverage and OAR sparing.
- 16 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 38 (2) , 406-416
Statistical Shape Model to Generate a Planning Library for Cervical Adaptive Radiotherapy
External beam radiotherapy is extensively used to treat cervical carcinomas. A single planning CT scan enables the calculation of the dose distribution. The treatment is delivered over 5 weeks. Large per-treatment anatomical variations may hamper the dose delivery, with the potential of an organs at risk (OAR) overdose and a tumor underdose. To anticipate these deformations, a recent approach proposed three planning CTs with variable bladder volumes, which had the limitation of not covering all per-treatment anatomical variations. An original patient-specific population-based library has been proposed. It consisted of generating two representative anatomies, in addition to the standard planning CT anatomy. First, the cervix and bladder meshes of a population of 20 patients (314 images) were registered to an anatomical template, using a deformable mesh registration. An iterative point-matching algorithm was developed based on local shape context (histogram of polar or cylindrical coordinates and geodesic distance to the base) and on a topology constraint filter. Second, a standard principal component analysis (PCA) model of the cervix and bladder was generated to extract the dominant deformation modes. Finally, specific deformations were obtained using posterior PCA models, with a constraint representing the top of the uterus deformation. For a new patient, the cervix-uterus and bladder were registered to the template, and the patient’s modeled planning library was built according to the model deformations. This method was applied following a leave-one-patient-out cross-validation. The performances of the modeled library were compared to those of the three-CT-based library and showing an improvement in both target coverage and OAR sparing.