Mean glandular dose coefficients (DgN) for x-ray spectra used in contemporary breast imaging systems
Authors:
- 8 September 2015
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (18) , 7179-7190
Abstract
To develop tables of normalized glandular dose coefficients for a range of anode–filter combinations and tube voltages used in contemporary breast imaging systems. Previously published mono-energetic values were used with various spectra to mathematically compute coefficients. The tungsten anode spectra from TASMICS were used; molybdenum and rhodium anode-spectra were generated using MCNPX Monte Carlo code. The spectra were filtered with various thicknesses of Al, Rh, Mo or Cu. An initial half value layer (HVL) calculation was made using the anode and filter material. A range of the HVL values was produced with the addition of small thicknesses of polymethyl methacrylate (PMMA) as a surrogate for the breast compression paddle, to produce a range of HVL values at each tube voltage. Using a spectral weighting method, coefficients for the generated spectra were calculated for breast glandular densities of 0%, 12.5%, 25%, 37.5%, 50% and 100% for a range of compressed breast thicknesses from 3 to 8 cm. Eleven tables of normalized glandular dose () coefficients were produced for the following anode/filter combinations: W + 50 μm Ag, W + 500 μm Al, W + 700 μm Al, W + 200 μm Cu, W + 300 μm Cu, W + 50 μm Rh, Mo + 400 μm Cu, Mo + 30 μm Mo, Mo + 25 μm Rh, Rh + 400 μm Cu and Rh + 25 μm Rh. Where possible, these results were compared to previously published values and were found to be on average less than 2% different than previously reported values. Over 200 pages of coefficients were computed for modeled x-ray system spectra that are used in a number of new breast imaging applications. The reported values were found to be in excellent agreement when compared to published values.Keywords
Funding Information
- National Institute of Biomedical Imaging and Bioengineering (R01 EB002138)
This publication has 19 references indexed in Scilit:
- Tungsten anode spectral model using interpolating cubic splines: Unfiltered x‐ray spectra from 20 kV to 640 kVMedical Physics, 2014
- Dedicated breast CT: radiation dose for circle-plus-line trajectoryMedical Physics, 2012
- Estimation of mean glandular dose for breast tomosynthesis: factors for use with the UK, European and IAEA breast dosimetry protocolsPhysics in Medicine & Biology, 2010
- The myth of the 50‐50 breastMedical Physics, 2009
- Technique factors and their relationship to radiation dose in pendant geometry breast CTMedical Physics, 2005
- Normalized glandular dose (DgN) coefficients for arbitrary x‐ray spectra in mammography: Computer‐fit values of Monte Carlo derived dataMedical Physics, 2002
- Glandular Breast Dose for Monoenergetic and High-Energy X-ray Beams: Monte Carlo AssessmentRadiology, 1999
- An accurate method for computer‐generating tungsten anode x‐ray spectra from 30 to 140 kVMedical Physics, 1997
- Parametrization of mammography normalized average glandular dose tablesMedical Physics, 1997
- Recommendations of the International Commission on Radiological Protection (ICRP) 1990European Journal of Nuclear Medicine and Molecular Imaging, 1992