Pulmonary Masses: Initial Results of Cone-beam CT Guidance with Needle Planning Software for Percutaneous Lung Biopsy
- 7 December 2011
- journal article
- research article
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 35 (6) , 1414-1421
Abstract
Purpose To evaluate the outcome of percutaneous lung biopsy (PLB) findings using cone-beam computed tomographic (CT) guidance (CBCT guidance) and compared to conventional biopsy guidance techniques. Methods CBCT guidance is a stereotactic technique for needle interventions, combining 3D soft-tissue cone-beam CT, needle planning software, and real-time fluoroscopy. Between March 2007 and August 2010, we performed 84 Tru-Cut PLBs, where bronchoscopy did not provide histopathologic diagnosis. Mean patient age was 64.6 (range 24–85) years; 57 patients were men, and 25 were women. Records were prospectively collected for calculating sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. We also registered fluoroscopy time, room time, interventional time, dose–area product (DAP), and complications. Procedures were divided into subgroups (e.g., location, size, operator). Results Mean lesion diameter was 32.5 (range 3.0–93.0) mm, and the mean number of samples per biopsy procedure was 3.2 (range 1–7). Mean fluoroscopy time was 161 (range 104–551) s, room time was 34 (range 15–79) min, mean DAP value was 25.9 (range 3.9–80.5) Gy·cm−2, and interventional time was 18 (range 5–65) min. Of 84 lesions, 70 were malignant (83.3%) and 14 were benign (16.7%). Seven (8.3%) of the biopsy samples were nondiagnostic. All nondiagnostic biopsied lesions proved to be malignant during surgical resection. The outcome for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was 90% (95% confidence interval [CI] 86–96), 100% (95% CI 82–100), 100% (95% CI 96–100), 66.7% (95% CI 55–83), and 91.7% (95% CI 86–96), respectively. Sixteen patients (19%) had minor and 2 (2.4%) had major complications. Conclusion CBCT guidance is an effective method for PLB, with results comparable to CT/CT fluoroscopy guidance.Keywords
This publication has 20 references indexed in Scilit:
- Quality Improvement Guidelines for Percutaneous Needle BiopsyJournal of Vascular and Interventional Radiology, 2010
- Real-Time 3D Fluoroscopy Guidance During Needle Interventions: Technique, Accuracy, and FeasibilityAmerican Journal of Roentgenology, 2010
- Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systemsEuropean Radiology, 2010
- Interventional radiology of the thoraxRespirology, 2010
- CT Fluoroscopy-Guided Biopsy of 1,000 Pulmonary Lesions Performed With 20-Gauge Coaxial Cutting NeedlesChest, 2009
- Lung Biopsy: Special TechniquesSeminars in Respiratory and Critical Care Medicine, 2008
- Ultrasound-assisted transthoracic biopsy: fine-needle aspiration or cutting-needle biopsy?European Respiratory Journal, 2006
- Accuracy and complications in computed tomography fluoroscopy-guided needle biopsies of lung massesEuropean Radiology, 2006
- CT Fluoroscopy–guided Biopsy of the Lung or Upper Abdomen with a Breath-hold Monitoring and Feedback System: A Prospective Randomized Controlled Clinical TrialRadiology, 2005
- US Guidance for Thoracic Biopsy: A Valuable Alternative to CTRadiology, 1999