Marco J. L. van Strijen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marco J. L. van Strijen has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Johannes P. M. van Heesewijk
St. Antonius Hospital, NL
2 shared publications - Sicco J. Braak
Department of Radiology, St. Antonius Hospital, P.O. Box 2500, 3430 EM, Nieuwegein, The Netherlands
2 shared publications - Anna M. Sailer
Department of Radiology, Stanford University School of Medicine, Stanford, CA, USA
1 shared publication - Daniel A. F. van Den Heuvel
Department of Radiology, St. Antonius Hospital, Nieuwegein, The Netherlands
1 shared publication - E Meijer
St. Antonius Hospital, NL
1 shared publication - Frank de Lange
Department of Radiology and Nuclear Medicine, Radboud University Medical Center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 1 November 2018
- Published by Springer Nature in Trials
- Vol. 19 (1) , 603
Fluoroscopy with MRA fusion image guidance in endovascular iliac artery interventions: study protocol for a randomized controlled trial (3DMR-Iliac-roadmapping study)
Endovascular iliac artery interventions rely on the use of two-dimensional digital subtraction angiographies with an iodinated contrast agent and ionizing radiation. The amount of iodinated contrast agent should be limited because of its potentially nephrotoxic effects. Three-dimensional (3D) image fusion requires registration of a preprocedural magnetic resonance angiogram (MRA) or computed tomography (CT) angiogram to a perprocedurally acquired cone-beam CT or two fluoroscopic orthogonal projections. After registration, the 3D angiography images can be overlaid on the fluoroscopy screen and will follow table and C-arm movements. This study will assess the added value of the 3D image fusion technique in iliac artery interventions regarding the amount of the iodinated contrast agent administered. The study cohort will comprise 106 patients (> 18 years) with symptomatic common and/or external iliac artery stenoses or occlusions and a recent (< 6 months) diagnostic MRA from the pelvis through the lower extremities, for which an endovascular intervention is indicated. Patients will be randomized into the control or study group (i.e. treatment without or with 3D image fusion guidance). The primary endpoint is the amount of administered iodinated contrast agent (mL). Secondary outcomes are technical success of the procedure, defined as < 30% residual stenosis over the treated lesion, fluoroscopy time, and radiation dose as dose area product (mGycm2). Patient participation in the study will be completed after hospital discharge. This study is a randomized controlled multicenter trial to provide evidence on the effect of the 3D image fusion technique on the amount of administered iodinated contrast during endovascular common and/or external iliac artery interventions. Nederlands Trial Register, NTR5008 . Registered on 16 December 2014.
- 1 November 2018
- Published by Springer Nature in Trials
- Vol. 19 (1) , 603
Open AccessFluoroscopy with MRA fusion image guidance in endovascular iliac artery interventions: study protocol for a randomized controlled trial (3DMR-Iliac-roadmapping study)
Endovascular iliac artery interventions rely on the use of two-dimensional digital subtraction angiographies with an iodinated contrast agent and ionizing radiation. The amount of iodinated contrast agent should be limited because of its potentially nephrotoxic effects. Three-dimensional (3D) image fusion requires registration of a preprocedural magnetic resonance angiogram (MRA) or computed tomography (CT) angiogram to a perprocedurally acquired cone-beam CT or two fluoroscopic orthogonal projections. After registration, the 3D angiography images can be overlaid on the fluoroscopy screen and will follow table and C-arm movements. This study will assess the added value of the 3D image fusion technique in iliac artery interventions regarding the amount of the iodinated contrast agent administered. The study cohort will comprise 106 patients (> 18 years) with symptomatic common and/or external iliac artery stenoses or occlusions and a recent (< 6 months) diagnostic MRA from the pelvis through the lower extremities, for which an endovascular intervention is indicated. Patients will be randomized into the control or study group (i.e. treatment without or with 3D image fusion guidance). The primary endpoint is the amount of administered iodinated contrast agent (mL). Secondary outcomes are technical success of the procedure, defined as < 30% residual stenosis over the treated lesion, fluoroscopy time, and radiation dose as dose area product (mGycm2). Patient participation in the study will be completed after hospital discharge. This study is a randomized controlled multicenter trial to provide evidence on the effect of the 3D image fusion technique on the amount of administered iodinated contrast during endovascular common and/or external iliac artery interventions. Nederlands Trial Register, NTR5008 . Registered on 16 December 2014.
- Open Access
- 19 April 2016
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (9) , 1322-1326
The Use of Laser Guidance Reduces Fluoroscopy Time for C-Arm Cone-Beam Computed Tomography-Guided Biopsies
Purpose When using laser guidance for cone-beam computed tomography (CBCT)-guided needle interventions, planned needle paths are visualized to the operator without the need to switch between entry- and progress-view during needle placement. The current study assesses the effect of laser guidance during CBCT-guided biopsies on fluoroscopy and procedure times. Materials and Methods Prospective data from 15 CBCT-guided biopsies of 8–65 mm thoracic and abdominal lesions assisted by a ceiling-mounted laser guidance technique were compared to retrospective data of 36 performed CBCT-guided biopsies of lesions >20 mm using the freehand technique. Fluoroscopy time, procedure time, and number of CBCT-scans were recorded. All data are presented as median (ranges). Results For biopsies using the freehand technique, more fluoroscopy time was necessary to guide the needle onto the target, 165 s (83–333 s) compared to 87 s (44–190 s) for laser guidance (p < 0.001). Procedure times were shorter for freehand-guided biopsies, 24 min versus 30 min for laser guidance (p < 0.001). Conclusion The use of laser guidance during CBCT-guided biopsies significantly reduces fluoroscopy time.
- 19 April 2016
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (9) , 1322-1326
Open AccessThe Use of Laser Guidance Reduces Fluoroscopy Time for C-Arm Cone-Beam Computed Tomography-Guided Biopsies
Purpose When using laser guidance for cone-beam computed tomography (CBCT)-guided needle interventions, planned needle paths are visualized to the operator without the need to switch between entry- and progress-view during needle placement. The current study assesses the effect of laser guidance during CBCT-guided biopsies on fluoroscopy and procedure times. Materials and Methods Prospective data from 15 CBCT-guided biopsies of 8–65 mm thoracic and abdominal lesions assisted by a ceiling-mounted laser guidance technique were compared to retrospective data of 36 performed CBCT-guided biopsies of lesions >20 mm using the freehand technique. Fluoroscopy time, procedure time, and number of CBCT-scans were recorded. All data are presented as median (ranges). Results For biopsies using the freehand technique, more fluoroscopy time was necessary to guide the needle onto the target, 165 s (83–333 s) compared to 87 s (44–190 s) for laser guidance (p < 0.001). Procedure times were shorter for freehand-guided biopsies, 24 min versus 30 min for laser guidance (p < 0.001). Conclusion The use of laser guidance during CBCT-guided biopsies significantly reduces fluoroscopy time.
- Open Access
- 26 February 2016
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 100 (1) , 40
Operator Radiation Exposure in Cone-Beam Computed Tomography Guidance
Quantitative analysis of operator dose in cone-beam computed tomography guidance (CBCT-guidance) and the effect of protective shielding. Using a Rando phantom, a model was set-up to measure radiation dose for the operator hand, thyroid and gonad region. The effect of sterile radiation-absorbing drapes and ceiling/couch shielding was measured. Using this model we calculated the dose, based on relevant clinical parameters. The procedures were divided in thoracic and abdominal group. Furthermore, dosimetry measurements were performed during clinical cases to correlate with our calculations. One hundred thirteen procedures were included between December 2007 and January 2010 (47 thoracic, 66 abdominal). The mean hand doses were 34.2 and 54.6 µSv (thoracic/abdominal respectively). The thyroid and gonad regions doses were 83.2 and 34.3 µSv in the thoracic, and 66.2 and 47.2 µSv in the abdominal group. Combined shielding reduced the dose by 98.2-98.9% (p<0.05). The radiation dose in clinical setting in the thoracic group (n=17) was 32.9 µSv (hand), 11.4 µSv (thyroid) and 16.0 µSv (gonad region). In the abdominal group (n=20) the doses were 43.4, 21.7 and 18.8 µSv respectively. The operator dose in CBCT-guidance without shielding is quite low, compared to the literature. Based on our data, between 375-830 cases can be performed staying below the yearly limit of 20 mSv effective whole-body dose.
- 26 February 2016
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 100 (1) , 40
Open AccessOperator Radiation Exposure in Cone-Beam Computed Tomography Guidance
Quantitative analysis of operator dose in cone-beam computed tomography guidance (CBCT-guidance) and the effect of protective shielding. Using a Rando phantom, a model was set-up to measure radiation dose for the operator hand, thyroid and gonad region. The effect of sterile radiation-absorbing drapes and ceiling/couch shielding was measured. Using this model we calculated the dose, based on relevant clinical parameters. The procedures were divided in thoracic and abdominal group. Furthermore, dosimetry measurements were performed during clinical cases to correlate with our calculations. One hundred thirteen procedures were included between December 2007 and January 2010 (47 thoracic, 66 abdominal). The mean hand doses were 34.2 and 54.6 µSv (thoracic/abdominal respectively). The thyroid and gonad regions doses were 83.2 and 34.3 µSv in the thoracic, and 66.2 and 47.2 µSv in the abdominal group. Combined shielding reduced the dose by 98.2-98.9% (p<0.05). The radiation dose in clinical setting in the thoracic group (n=17) was 32.9 µSv (hand), 11.4 µSv (thyroid) and 16.0 µSv (gonad region). In the abdominal group (n=20) the doses were 43.4, 21.7 and 18.8 µSv respectively. The operator dose in CBCT-guidance without shielding is quite low, compared to the literature. Based on our data, between 375-830 cases can be performed staying below the yearly limit of 20 mSv effective whole-body dose.
- Open Access
- 1 May 2015
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 26 (5) , 642-650.e1
Evaluation of a Noise Reduction Imaging Technology in Iliac Digital Subtraction Angiography: Noninferior Clinical Image Quality with Lower Patient and Scatter Dose
- 1 May 2015
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 26 (5) , 642-650.e1
Open AccessEvaluation of a Noise Reduction Imaging Technology in Iliac Digital Subtraction Angiography: Noninferior Clinical Image Quality with Lower Patient and Scatter Dose
- 18 July 2014
- Vol. 55 (5) , 581-92
Experience with new techniques for the treatment of type II endoleaks post-EVAR.
Endovascular aneurysm management (EVAR) is hampered by persistent arterial blood flow in the aneurysm sac after treatment, known as endoleak (EL). Type II EL consist of blood flow from one or more aortic branch vessels; they only require treatment when the aneurysm sac fails to shrink. Post-EVAR follow up is mostly done with contrast enhanced computed tomography. If a type II EL requiring treatment is found, a variety of options exist, depending on the source of EL and the anatomy. Inferior mesenteric artery EL is best treated by endovascular embolization through the superior mesenteric artery and Riolans' arc. In hypogastric to lumbar artery EL success of endovascular treatment is limited. In these cases a successful embolization of the EL can often be performed by a direct percutaneous approach to the EL inside the aneurysmal sac. CT guidance provides a good way to exactly puncture the EL percutaneously in most cases, but limited workspace and lack of fluoroscopy availability for the ensuing catheter manipulation hampers this technique. A novel way to puncture the EL and subsequently treat it is performed on flat panel detector angiography units. By a rotation around the patients these units provide the possibility to create a cone-beam CT (CBCT) in the angio suite. Using the 3-dimensional dataset thus acquired, a needle path can be planned and the EL nidus can be punctured with great confidence and without danger of inadvertently perforating vital structures. After the EL has been punctured, microcatheters can be inserted to embolize the origins of branch vessels and/or the aneurysm sac can be filled with thrombogenic agents or glue. CBCT guided procedures incur lower radiation dose and have higher accuracy compared to conventional CT guided procedures. Details of CBCT guided procedures; the materials and technique used are detailed in this manuscript.
- 18 July 2014
- Vol. 55 (5) , 581-92
Experience with new techniques for the treatment of type II endoleaks post-EVAR.
Endovascular aneurysm management (EVAR) is hampered by persistent arterial blood flow in the aneurysm sac after treatment, known as endoleak (EL). Type II EL consist of blood flow from one or more aortic branch vessels; they only require treatment when the aneurysm sac fails to shrink. Post-EVAR follow up is mostly done with contrast enhanced computed tomography. If a type II EL requiring treatment is found, a variety of options exist, depending on the source of EL and the anatomy. Inferior mesenteric artery EL is best treated by endovascular embolization through the superior mesenteric artery and Riolans' arc. In hypogastric to lumbar artery EL success of endovascular treatment is limited. In these cases a successful embolization of the EL can often be performed by a direct percutaneous approach to the EL inside the aneurysmal sac. CT guidance provides a good way to exactly puncture the EL percutaneously in most cases, but limited workspace and lack of fluoroscopy availability for the ensuing catheter manipulation hampers this technique. A novel way to puncture the EL and subsequently treat it is performed on flat panel detector angiography units. By a rotation around the patients these units provide the possibility to create a cone-beam CT (CBCT) in the angio suite. Using the 3-dimensional dataset thus acquired, a needle path can be planned and the EL nidus can be punctured with great confidence and without danger of inadvertently perforating vital structures. After the EL has been punctured, microcatheters can be inserted to embolize the origins of branch vessels and/or the aneurysm sac can be filled with thrombogenic agents or glue. CBCT guided procedures incur lower radiation dose and have higher accuracy compared to conventional CT guided procedures. Details of CBCT guided procedures; the materials and technique used are detailed in this manuscript.
- 7 December 2011
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 35 (6) , 1414-1421
Pulmonary Masses: Initial Results of Cone-beam CT Guidance with Needle Planning Software for Percutaneous Lung Biopsy
Purpose To evaluate the outcome of percutaneous lung biopsy (PLB) findings using cone-beam computed tomographic (CT) guidance (CBCT guidance) and compared to conventional biopsy guidance techniques. Methods CBCT guidance is a stereotactic technique for needle interventions, combining 3D soft-tissue cone-beam CT, needle planning software, and real-time fluoroscopy. Between March 2007 and August 2010, we performed 84 Tru-Cut PLBs, where bronchoscopy did not provide histopathologic diagnosis. Mean patient age was 64.6 (range 24–85) years; 57 patients were men, and 25 were women. Records were prospectively collected for calculating sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. We also registered fluoroscopy time, room time, interventional time, dose–area product (DAP), and complications. Procedures were divided into subgroups (e.g., location, size, operator). Results Mean lesion diameter was 32.5 (range 3.0–93.0) mm, and the mean number of samples per biopsy procedure was 3.2 (range 1–7). Mean fluoroscopy time was 161 (range 104–551) s, room time was 34 (range 15–79) min, mean DAP value was 25.9 (range 3.9–80.5) Gy·cm−2, and interventional time was 18 (range 5–65) min. Of 84 lesions, 70 were malignant (83.3%) and 14 were benign (16.7%). Seven (8.3%) of the biopsy samples were nondiagnostic. All nondiagnostic biopsied lesions proved to be malignant during surgical resection. The outcome for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was 90% (95% confidence interval [CI] 86–96), 100% (95% CI 82–100), 100% (95% CI 96–100), 66.7% (95% CI 55–83), and 91.7% (95% CI 86–96), respectively. Sixteen patients (19%) had minor and 2 (2.4%) had major complications. Conclusion CBCT guidance is an effective method for PLB, with results comparable to CT/CT fluoroscopy guidance.
- 7 December 2011
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 35 (6) , 1414-1421
Pulmonary Masses: Initial Results of Cone-beam CT Guidance with Needle Planning Software for Percutaneous Lung Biopsy
Purpose To evaluate the outcome of percutaneous lung biopsy (PLB) findings using cone-beam computed tomographic (CT) guidance (CBCT guidance) and compared to conventional biopsy guidance techniques. Methods CBCT guidance is a stereotactic technique for needle interventions, combining 3D soft-tissue cone-beam CT, needle planning software, and real-time fluoroscopy. Between March 2007 and August 2010, we performed 84 Tru-Cut PLBs, where bronchoscopy did not provide histopathologic diagnosis. Mean patient age was 64.6 (range 24–85) years; 57 patients were men, and 25 were women. Records were prospectively collected for calculating sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. We also registered fluoroscopy time, room time, interventional time, dose–area product (DAP), and complications. Procedures were divided into subgroups (e.g., location, size, operator). Results Mean lesion diameter was 32.5 (range 3.0–93.0) mm, and the mean number of samples per biopsy procedure was 3.2 (range 1–7). Mean fluoroscopy time was 161 (range 104–551) s, room time was 34 (range 15–79) min, mean DAP value was 25.9 (range 3.9–80.5) Gy·cm−2, and interventional time was 18 (range 5–65) min. Of 84 lesions, 70 were malignant (83.3%) and 14 were benign (16.7%). Seven (8.3%) of the biopsy samples were nondiagnostic. All nondiagnostic biopsied lesions proved to be malignant during surgical resection. The outcome for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was 90% (95% confidence interval [CI] 86–96), 100% (95% CI 82–100), 100% (95% CI 96–100), 66.7% (95% CI 55–83), and 91.7% (95% CI 86–96), respectively. Sixteen patients (19%) had minor and 2 (2.4%) had major complications. Conclusion CBCT guidance is an effective method for PLB, with results comparable to CT/CT fluoroscopy guidance.