SBSicco J. Braak

Sicco J. Braak

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sicco J. Braak has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Use of Laser Guidance Reduces Fluoroscopy Time for C-Arm Cone-Beam Computed Tomography-Guided Biopsies

    by Maarten W. Kroes, Marco J. L. van Strijen, Sicco J. Braak, Yvonne L. Hoogeveen, Frank de Lange, Leo J. Schultze Kool

    Purpose When using laser guidance for cone-beam computed tomography (CBCT)-guided needle interventions, planned needle paths are visualized to the operator without the need to switch between entry- and progress-view during needle placement. The current study assesses the effect of laser guidance during CBCT-guided biopsies on fluoroscopy and procedure times. Materials and Methods Prospective data from 15 CBCT-guided biopsies of 8–65 mm thoracic and abdominal lesions assisted by a ceiling-mounted laser guidance technique were compared to retrospective data of 36 performed CBCT-guided biopsies of lesions >20 mm using the freehand technique. Fluoroscopy time, procedure time, and number of CBCT-scans were recorded. All data are presented as median (ranges). Results For biopsies using the freehand technique, more fluoroscopy time was necessary to guide the needle onto the target, 165 s (83–333 s) compared to 87 s (44–190 s) for laser guidance (p < 0.001). Procedure times were shorter for freehand-guided biopsies, 24 min versus 30 min for laser guidance (p < 0.001). Conclusion The use of laser guidance during CBCT-guided biopsies significantly reduces fluoroscopy time.


  • Feasibility Study of Needle Placement in Percutaneous Vertebroplasty: Cone-Beam Computed Tomography Guidance Versus Conventional Fluoroscopy

    by Sicco J. Braak, Kirsten Zuurmond, Hans C. J. Aerts, Marc van Leersum, Timotheus T. Th. Overtoom, Johannes P. M. van Heesewijk, Marco J. L. van Strijen

    To investigate the accuracy, procedure time, fluoroscopy time, and dose area product (DAP) of needle placement during percutaneous vertebroplasty (PVP) using cone-beam computed tomography (CBCT) guidance versus fluoroscopy.


  • Open Access

    3D cone-beam CT guidance, a novel technique in renal biopsy—results in 41 patients with suspected renal masses

    by Sicco J. Braak, Harm H. E. van Melick, Mircea G. Onaca, Johannes P. M. van Heesewijk, Marco J. L. van Strijen

    Objective To determine whether 3D cone-beam computed tomography (CBCT) guidance allows safe and accurate biopsy of suspected small renal masses (SRM), especially in hard-to-reach anatomical locations. Materials and methods CBCT guidance was used to perform 41 stereotactic biopsy procedures of lesions that were inaccessible for ultrasound guidance or CT guidance. In CBCT guidance, a 3D-volume data set is acquired by rotating a C-arm flat-panel detector angiosystem around the patient. In the data set, a needle trajectory is determined and, after co-registration, a fusion image is created from fluoroscopy and a slice from the data set, enabling the needle to be positioned in real time. Results Of the 41 lesions, 22 were malignant, 17 were benign, and 2 were nondiagnostic. The two nondiagnostic lesions proved to be renal cell carcinoma. There was no growth during follow-up imaging of the benign lesions (mean 29 months). This resulted in a sensitivity, specificity, PPV, NPV, and accuracy of 91.7, 100, 100, 89.5, and 95.1%, respectively. Mean dose-area product value was 44.0 Gy·cm2 (range 16.5–126.5). There was one minor bleeding complication. Conclusion With CBCT guidance, safe and accurate biopsy of a suspected SRM is feasible, especially in hard-to-reach locations of the kidney. Key Points • Cone-beam computed tomography has potential advantages over conventional CT for interventional procedures. • CBCT guidance incorporates 3D CBCT data, fluoroscopy, and guidance software. • In hard-to-reach renal masses, CBCT guidance offers an alternative biopsy method. • CBCT guidance offers good outcome and safety and has potential clinical significance.


  • Pulmonary Masses: Initial Results of Cone-beam CT Guidance with Needle Planning Software for Percutaneous Lung Biopsy

    by Sicco J. Braak, Gerarda J. M. Herder, Johannes P. M. van Heesewijk, Marco J. L. van Strijen

    Purpose To evaluate the outcome of percutaneous lung biopsy (PLB) findings using cone-beam computed tomographic (CT) guidance (CBCT guidance) and compared to conventional biopsy guidance techniques. Methods CBCT guidance is a stereotactic technique for needle interventions, combining 3D soft-tissue cone-beam CT, needle planning software, and real-time fluoroscopy. Between March 2007 and August 2010, we performed 84 Tru-Cut PLBs, where bronchoscopy did not provide histopathologic diagnosis. Mean patient age was 64.6 (range 24–85) years; 57 patients were men, and 25 were women. Records were prospectively collected for calculating sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. We also registered fluoroscopy time, room time, interventional time, dose–area product (DAP), and complications. Procedures were divided into subgroups (e.g., location, size, operator). Results Mean lesion diameter was 32.5 (range 3.0–93.0) mm, and the mean number of samples per biopsy procedure was 3.2 (range 1–7). Mean fluoroscopy time was 161 (range 104–551) s, room time was 34 (range 15–79) min, mean DAP value was 25.9 (range 3.9–80.5) Gy·cm−2, and interventional time was 18 (range 5–65) min. Of 84 lesions, 70 were malignant (83.3%) and 14 were benign (16.7%). Seven (8.3%) of the biopsy samples were nondiagnostic. All nondiagnostic biopsied lesions proved to be malignant during surgical resection. The outcome for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was 90% (95% confidence interval [CI] 86–96), 100% (95% CI 82–100), 100% (95% CI 96–100), 66.7% (95% CI 55–83), and 91.7% (95% CI 86–96), respectively. Sixteen patients (19%) had minor and 2 (2.4%) had major complications. Conclusion CBCT guidance is an effective method for PLB, with results comparable to CT/CT fluoroscopy guidance.


    • 1 June 2009
      • Vol. 47  (2) , 166-71

    Percutaneous embolization on hereditary hemorrhagic telangiectasia patients with severe epistaxis.

    by S J Braak, C A De Witt, F J M Disch, T Th C Overtoom, J J Westermann

    To evaluate the results of embolization in patients with hereditary hemorrhagic telangiectasia (HHT) because of severe epistaxis. All HHT patients who underwent an embolization (between 1992 and 2006) were asked to participate in this retrospective study. Twelve patients who had in total 19 embolization procedures were interviewed. A questionnaire was used assessing the frequency, severity, duration of epistaxis and their Impact on Lifestyle (IoL). Haemoglobin values were collected from the patients' records. Embolization of the pathologically enhancing lesions was performed using PVA particles. The direct effect of the embolization is very good in 95% of patients. The Impact factor (daily frequency x severity) of epistaxis improved in the first month (p = 0.000) and one year after embolization (p = 0.009). Eleven embolizations (61%) were still associated with significant improvement. There was a reduction in the duration of epistaxis by 16 minutes per day one month after embolization (p = 0.005). However, this reduction was not found one year after embolization. Mean haemoglobin rose significantly after 1 year by an average of 0.8 mmol/l (p = 0.045). Impact on Lifestyle improved in 68% of the procedures and was unchanged in 32%. Embolizations remain a therapeutic option in experienced hands. The indication should be made carefully, because of possible (major) complications.