Latest Publications

  • Open Access

    Slice encoding for metal artifact correction with noise reduction

    by Wenmiao Lu, Kim B. Pauly, Garry E. Gold, John M. Pauly, Brian A. Hargreaves

    Magnetic resonance imaging (MRI) near metallic implants is often hampered by severe metal artifacts. To obtain distortion‐free MR images near metallic implants, SEMAC (Slice Encoding for Metal Artifact Correction) corrects metal artifacts via robust encoding of excited slices against metal‐induced field inhomogeneities, followed by combining the data resolved from multiple SEMAC‐encoded slices. However, as many of the resolved data elements only contain noise, SEMAC‐corrected images can suffer from relatively low signal‐to‐noise ratio. Improving the signal‐to‐noise ratio of SEMAC‐corrected images is essential to enable SEMAC in routine clinical studies. In this work, a new reconstruction procedure is proposed to reduce noise in SEMAC‐corrected images. A singular value decomposition denoising step is first applied to suppress quadrature noise in multi‐coil SEMAC‐encoded slices. Subsequently, the singular value decomposition‐denoised data are selectively included in the correction of through‐plane distortions. The experimental results demonstrate that the proposed reconstruction procedure significantly improves the SNR without compromising the correction of metal artifacts. Magn Reson Med, 2011.


  • Open Access

    SEMAC: Slice encoding for metal artifact correction in MRI

    by Wenmiao Lu, Kim Butts Pauly, Garry E. Gold, John M. Pauly, Brian A. Hargreaves

    Magnetic resonance imaging (MRI) near metallic implants remains an unmet need because of severe artifacts, which mainly stem from large metal‐induced field inhomogeneities. This work addresses MRI near metallic implants with an innovative imaging technique called “Slice Encoding for Metal Artifact Correction” (SEMAC). The SEMAC technique corrects metal artifacts via robust encoding of each excited slice against metal‐induced field inhomogeneities. The robust slice encoding is achieved by extending a view‐angle‐tilting (VAT) spin‐echo sequence with additional z‐phase encoding. Although the VAT compensation gradient suppresses most in‐plane distortions, the z‐phase encoding fully resolves distorted excitation profiles that cause through‐plane distortions. By positioning all spins in a region‐of‐interest to their actual spatial locations, the through‐plane distortions can be corrected by summing up the resolved spins in each voxel. The SEMAC technique does not require additional hardware and can be deployed to the large installed base of whole‐body MRI systems. The efficacy of the SEMAC technique in eliminating metal‐induced distortions with feasible scan times is validated in phantom and in vivo spine and knee studies. Magn Reson Med 62:66–76, 2009.