Recent advances in nuclear cardiology instrumentation have enabled myocardial perfusion imaging (MPI) with improved image quality and faster scan times. These developments also can be exploited to reduce the effective radiation dose to the patient. In this review, we discuss these technologies including new single photon emission computed tomography (SPECT) and positron emission tomography (PET) scanners, as well as novel reconstruction software with regard to their potential for the reduction of the patient radiation dose. New advances in nuclear cardiology instrumentation will allow routine rest/stress MPI imaging with low radiation doses (<5 mSv) and fast imaging times, even by the software-only solutions. It is possible to further reduce the MPI radiation dose to less than 2 to 3 mSv range with standard acquisition times. PET perfusion imaging also can be performed with very low doses especially by the three-dimensional scanners allowing hybrid PET/computed tomographic angiography (CTA) imaging with low overall dose. In addition, stress-only protocols can be utilized to further reduce the radiation dose and the overall test time.Keywords
This publication has 56 references indexed in Scilit:
- Motion frozen 18F-FDG cardiac PETJournal of Nuclear Cardiology, 2010
- Agreement of Visual Estimation of Coronary Artery Calcium From Low-Dose CT Attenuation Correction Scans in Hybrid PET/CT and SPECT/CT With Standard Agatston ScoreJACC, 2010
- Human Biodistribution and Radiation Dosimetry of 82RbJournal of Nuclear Medicine, 2010
- New Imaging Protocols for New Single Photon Emission CT TechnologiesCurrent Cardiovascular Imaging Reports, 2010
- Enhanced definition PET for cardiac imagingJournal of Nuclear Cardiology, 2010
- Multicenter investigation comparing a highly efficient half-time stress-only attenuation correction approach against standard rest-stress Tc-99m SPECT imagingJournal of Nuclear Cardiology, 2009
- Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: multicenter comparison with standard dual detector camerasJournal of Nuclear Cardiology, 2009
- The Linear No-Threshold Relationship Is Inconsistent with Radiation Biologic and Experimental DataRadiology, 2009
- Half-Time SPECT Myocardial Perfusion Imaging with Attenuation CorrectionJournal of Nuclear Medicine, 2009
- High-Speed Myocardial Perfusion ImagingJACC: Cardiovascular Imaging, 2008