AMAnton Mans

Anton Mans

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Anton Mans has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reduction of systematic dosimetric uncertainties in volumetric modulated arc therapy triggered by patient-specific quality assurance

    by Anton Mans, Roel Rozendaal, Tomas Janssen, Eugène Damen, Jochem Kaas, Anke van Mourik, Ben Mijnheer


  • Characterization of Gas Electron Multiplier‐based detector for external beam radiation therapy dosimetry

    by Daniel Muñoz, Igor Olaciregui‐Ruiz, Gunnar Norberg, Uulke A. van der Heide, Anton Mans

    Purpose Electronic Portal Imaging Devices (EPIDs) are commonly installed on modern linear accelerators (LINACs) and are convenient for imaging and, potentially, dosimetry. However, owing to their construction with metal and scintillating layers of high atomic number, they exhibit non‐water‐equivalent response and oversensitivity to low‐energy photons. Therefore, EPIDs are not ideal for dosimetry purposes. Additionally, non‐linearities due to the combined use of scintillators and photodiodes have been reported. Here, an EPID which employs a variable gain Gas Electron Multiplier (GEM) and direct detection of electrons is introduced. To investigate its dosimetric performance, measurements characterizing the novel EPID are performed and compared with measurements from ionization chambers and conventional EPIDs. Methods Linearity, dose rate dependence, field size dependence, off‐axis response and transmission response were measured for all available energy settings (6 MV, 10 MV, 6 MV Flattening Filter Free (FFF) and 10 MVFFF) using three different detector gain settings. Additionally, an evaluation of the ghosting and image lag of the panel was completed. Reference ionization chamber measurements were performed for the off‐axis and transmission response and existing data for conventional EPIDs and ionization chambers from equivalent measurements were used for comparison of the field size dependence. Elsewhere, values from the linac monitoring chambers were used. Results In the range from 10 to 1000 Monitor Units (MU), the detector was linear within 1 % for all combinations of gain settings and energies. The dose rate dependence was also within 1% for all energies and for 2 out of 3 gain settings. Regarding field size dependency, the ratio of ionization chamber and panel values was 0.94 and 0.98 for the conventional EPID and GEMini respectively, at 20 x 20 cm2 and 10MV. For 6MV, 6MVFFF and 10MVFFF these ratios were 0.97, 0.98, 0.99 for the GEMini, and 0.95, 0.97 and 0.97 for the conventional EPID. Similar performance between the GEMini and conventional EPID is observed for field sizes smaller than 10 x 10 cm2. The transmission response was within 5 % for all energies for thicknesses up to 30 cm, compared to 10 – 20 % for a conventional EPID. The off‐axis response for shifts up to 16 cm was within 1 % and 3 % for 6 MV and 10 MV, with and without phantom. The rise and fall of the signal from the detector correspond well to monitor chamber measurements indicating little ghosting and image lag, regardless of gain setting. Conclusion The GEM EPID exhibits dose rate dependence and linearity within 1%, and negligible ghosting and image lag. In this regard, it performs particularly well using 50 V and 250 V of gain, and either could be chosen. For higher sensitivity 250 V is the recommended base gain setting, though other applications may warrant different gains. For most tests performed in this study, the GEM EPID demonstrates a more water‐equivalent response than conventional EPIDs making GEMs a viable technology for dosimetry in radiation therapy.

  • A back-projection algorithm in the presence of an extra attenuating medium: towards EPID dosimetry for the MR-Linac

    by I Torres-Xirau, I Olaciregui-Ruiz, R A Rozendaal, P González, B J Mijnheer, J-J Sonke, U A van der Heide, A Mans

    In external beam radiotherapy, electronic portal imaging devices (EPIDs) are frequently used for pre-treatment and for in vivo dose verification. Currently, various MR-guided radiotherapy systems are being developed and clinically implemented. Independent dosimetric verification is highly desirable. For this purpose we adapted our EPID-based dose verification system for use with the MR-Linac combination developed by Elekta in cooperation with UMC Utrecht and Philips. In this study we extended our back-projection method to cope with the presence of an extra attenuating medium between the patient and the EPID. Experiments were performed at a conventional linac, using an aluminum mock-up of the MRI scanner housing between the phantom and the EPID. For a 10 cm square field, the attenuation by the mock-up was 72%, while 16% of the remaining EPID signal resulted from scattered radiation. 58 IMRT fields were delivered to a 20 cm slab phantom with and without the mock-up. EPID reconstructed dose distributions were compared to planned dose distributions using the γ -evaluation method (global, 3%, 3 mm). In our adapted back-projection algorithm the averaged γ m e a n was 0.27 ± 0.06 , while in the conventional it was 0.28 ± 0.06 . Dose profiles of several square fields reconstructed with our adapted algorithm showed excellent agreement when compared to TPS.


  • The NCS code of practice for the quality assurance and control for volumetric modulated arc therapy

    by Anton Mans, Danny Schuring, Mark P Arends, Cornelia A J M Vugts, Jochem W H Wolthaus, Heidi T Lotz, Marjan Admiraal, Rob J W Louwe, Michel C Öllers, Jeroen B van de Kamer

    In 2010, the NCS (Netherlands Commission on Radiation Dosimetry) installed a subcommittee to develop guidelines for quality assurance and control for volumetric modulated arc therapy (VMAT) treatments. The report (published in 2015) has been written by Dutch medical physicists and has therefore, inevitably, a Dutch focus. This paper is a condensed version of these guidelines, the full report in English is freely available from the NCS website www.radiationdosimetry.org . After describing the transition from IMRT to VMAT, the paper addresses machine quality assurance (QA) and treatment planning system (TPS) commissioning for VMAT. The final section discusses patient specific QA issues such as the use of class solutions, measurement devices and dose evaluation methods.


  • Catching errors with in vivo EPID dosimetry

    by A. Mans, M. Wendling, L. N. McDermott, J.‐J. Sonke, R. Tielenburg, R. Vijlbrief, B. Mijnheer, M. van Herk, J. C. Stroom

    The potential for detrimental incidents and the ever increasing complexity of patient treatments emphasize the need for accurate dosimetric verification in radiotherapy. For this reason, all curative treatments are verified, either pretreatment or in vivo, by electronic portal imaging device (EPID) dosimetry in the Radiation Oncology Department of the Netherlands Cancer Institute‐Antoni van Leeuwenhoek hospital, Amsterdam, The Netherlands. Since the clinical introduction of the method in January 2005 until August 2009, treatment plans of 4337 patients have been verified. Among these plans, 17 serious errors were detected that led to intervention. Due to their origin, nine of these errors would not have been detected with pretreatment verification. The method is illustrated in detail by the case of a plan transfer error detected in a intensity‐modulated radiotherapy (IMRT) rectum treatment. The EPID reconstructed dose at the isocenter was 6.3% below the planned value. Investigation of the plan transfer chain revealed that due to a network transfer error, the plan was corrupted. 3D analysis of the acquired EPID data revealed serious underdosage of the planning target volume: On average 11.6%, locally up to 20%. This report shows the importance of in vivo (EPID) dosimetry for all treatment plans as well as the ability of the method to assess the dosimetric impact of deviations found.


  • 3D Dosimetric verification of volumetric-modulated arc therapy by portal dosimetry

    by Anton Mans, Peter Remeijer, Igor Olaciregui-Ruiz, Markus Wendling, Jan-Jakob Sonke, Ben Mijnheer, Marcel van Herk, Joep C. Stroom