Kristy L. Perez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kristy L. Perez has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Priti Madhav
Biomedical Engineering and Radiology Departments, Duke University, Durham, NC, USA
2 shared publicationsJan H. Pachon
Medical Physics Program and Radiology Department, Duke University, Durham, NC 27710 USA
1 shared publicationMartin P. Tornai
Medical Physics Program and Radiology Department, Duke University, Durham, NC 27710 USA
1 shared publication- Martin P. Tornai
Duke University
1 shared publication - Martin P. Tornai
Duke University
1 shared publication P Madhav
Department of Radiology, Duke University Medical Center, Durham, NC 27710, USA
1 shared publication
Latest Publications
- 3 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 58 (5) , 2219-2225
Towards Quantification of Functional Breast Images Using Dedicated SPECT With Non-Traditional Acquisition Trajectories
Quantification of radiotracer uptake in breast lesions can provide valuable information to physicians in deciding patient care or determining treatment efficacy. Physical processes (e.g., scatter, attenuation), detector/collimator characteristics, sampling and acquisition trajectories, and reconstruction artifacts contribute to an incorrect measurement of absolute tracer activity and distribution. For these experiments, a cylinder with three syringes of varying radioactivity concentration, and a fillable 800 mL breast with two lesion phantoms containing aqueous 99m Tc pertechnetate were imaged using the SPECT sub-system of the dual-modality SPECT-CT dedicated breast scanner. SPECT images were collected using a compact CZT camera with various 3D acquisitions including vertical axis of rotation, 30° tilted, and complex sinusoidal trajectories. Different energy windows around the photopeak were quantitatively compared, along with appropriate scatter energy windows, to determine the best quantification accuracy after attenuation and dual-window scatter correction. Measured activity concentrations in the reconstructed images for syringes with greater than 10 μCi/mL corresponded to within 10% of the actual dose calibrator measured activity concentration for ±4% and ±8% photopeak energy windows. The same energy windows yielded lesion quantification results within 10% in the breast phantom as well. Results for the more complete complex sinsusoidal trajectory are similar to the simple vertical axis acquisition, and additionally allows both anterior chest wall sampling, no image distortion, and reasonably accurate quantification.
- 3 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 58 (5) , 2219-2225
Towards Quantification of Functional Breast Images Using Dedicated SPECT With Non-Traditional Acquisition Trajectories
Quantification of radiotracer uptake in breast lesions can provide valuable information to physicians in deciding patient care or determining treatment efficacy. Physical processes (e.g., scatter, attenuation), detector/collimator characteristics, sampling and acquisition trajectories, and reconstruction artifacts contribute to an incorrect measurement of absolute tracer activity and distribution. For these experiments, a cylinder with three syringes of varying radioactivity concentration, and a fillable 800 mL breast with two lesion phantoms containing aqueous 99m Tc pertechnetate were imaged using the SPECT sub-system of the dual-modality SPECT-CT dedicated breast scanner. SPECT images were collected using a compact CZT camera with various 3D acquisitions including vertical axis of rotation, 30° tilted, and complex sinusoidal trajectories. Different energy windows around the photopeak were quantitatively compared, along with appropriate scatter energy windows, to determine the best quantification accuracy after attenuation and dual-window scatter correction. Measured activity concentrations in the reconstructed images for syringes with greater than 10 μCi/mL corresponded to within 10% of the actual dose calibrator measured activity concentration for ±4% and ±8% photopeak energy windows. The same energy windows yielded lesion quantification results within 10% in the breast phantom as well. Results for the more complete complex sinsusoidal trajectory are similar to the simple vertical axis acquisition, and additionally allows both anterior chest wall sampling, no image distortion, and reasonably accurate quantification.
- 1 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2010 (10823654) , 2319-2324
Is SPECT or CT based attenuation correction more quantitatively accurate for dedicated breast SPECT acquired with non-traditional trajectories?
Attenuation correction is necessary for SPECT quantification. There are a variety of methods to create attenuation maps. For dedicated breast SPECT-CT imaging, it is unclear if either a SPECT- or CT-based attenuation map would provide the most accurate quantification and whether or not segmenting the different tissue types will have an effect on the quantification. For these experiments, 99m Tc diluted in methanol and water filled geometric and anthropomorphic breast phantoms was imaged with a dedicated dual-modality SPECT-CT breast scanner. SPECT images were collected using a compact CZT camera with various 3D acquisition trajectories including vertical and 30° tilted parallel beam, and complex sinusoidal trajectories. CT images were acquired using a quasi-monochromatic x-ray source and CsI(Tl) digital flat panel detector in a half-cone beam geometry. Measured scatter correction for SPECT and CT were implemented. To compare photon attenuation correction in the reconstructed SPECT images, various volumetric attenuation maps were derived from 1) uniform SPECT, 2) uniform CT, and 3) segmented CT, populated with different attenuation coefficient values. Comparisons between attenuation masks using phantoms consisting of materials with different attenuation values show that at 140 keV the differences in the attenuation between materials do not affect the quantification as much as the size and alignment of the attenuation map. The CT-based attenuation maps give quantitative values 30% below the actual value, but are consistent. The SPECT-based attenuation maps can provide within 10% accurate quantitative values, but are less consistent.
- 1 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2010 (10823654) , 2319-2324
Is SPECT or CT based attenuation correction more quantitatively accurate for dedicated breast SPECT acquired with non-traditional trajectories?
Attenuation correction is necessary for SPECT quantification. There are a variety of methods to create attenuation maps. For dedicated breast SPECT-CT imaging, it is unclear if either a SPECT- or CT-based attenuation map would provide the most accurate quantification and whether or not segmenting the different tissue types will have an effect on the quantification. For these experiments, 99m Tc diluted in methanol and water filled geometric and anthropomorphic breast phantoms was imaged with a dedicated dual-modality SPECT-CT breast scanner. SPECT images were collected using a compact CZT camera with various 3D acquisition trajectories including vertical and 30° tilted parallel beam, and complex sinusoidal trajectories. CT images were acquired using a quasi-monochromatic x-ray source and CsI(Tl) digital flat panel detector in a half-cone beam geometry. Measured scatter correction for SPECT and CT were implemented. To compare photon attenuation correction in the reconstructed SPECT images, various volumetric attenuation maps were derived from 1) uniform SPECT, 2) uniform CT, and 3) segmented CT, populated with different attenuation coefficient values. Comparisons between attenuation masks using phantoms consisting of materials with different attenuation values show that at 140 keV the differences in the attenuation between materials do not affect the quantification as much as the size and alignment of the attenuation map. The CT-based attenuation maps give quantitative values 30% below the actual value, but are consistent. The SPECT-based attenuation maps can provide within 10% accurate quantitative values, but are less consistent.
- Open Access
- 30 July 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (16) , 4721-4734
Characterizing the contribution of cardiac and hepatic uptake in dedicated breast SPECT using tilted trajectories
A small field of view, high resolution gamma camera has been integrated into a dedicated breast, single photon emission computed tomography (SPECT) device. The detector can be flexibly positioned relative to the breast and image beyond the chest wall, allowing the system to capture direct views of the heart and liver. The incomplete sampling of these organs creates artifacts in reconstructed images, complicating lesion detection. To understand the limits imposed on a 3D acquisition trajectory, sequential tilted trajectories at increasing polar tilt are utilized to collect data of anthropomorphic phantoms filled with aqueous (99m)Tc in a clinically realistic concentration ratio. The counts collected per projection between different scans and the SNR, contrast and resolution (FWHM) of two hot lesions were compared. As expected, the counts per projection increased when the camera had direct views of the heart and liver, but remained relatively constant at other angles. The SNR, contrast and FWHM were more affected by the insufficient sampling of the data by the large polar angles than by the cardiac and hepatic activity. An upper bound on polar tilt for each azimuthal position reduces the artifacts in the reconstructed images. Such trajectories were implemented to show artifact-free reconstructed images.
- 30 July 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (16) , 4721-4734
Open AccessCharacterizing the contribution of cardiac and hepatic uptake in dedicated breast SPECT using tilted trajectories
A small field of view, high resolution gamma camera has been integrated into a dedicated breast, single photon emission computed tomography (SPECT) device. The detector can be flexibly positioned relative to the breast and image beyond the chest wall, allowing the system to capture direct views of the heart and liver. The incomplete sampling of these organs creates artifacts in reconstructed images, complicating lesion detection. To understand the limits imposed on a 3D acquisition trajectory, sequential tilted trajectories at increasing polar tilt are utilized to collect data of anthropomorphic phantoms filled with aqueous (99m)Tc in a clinically realistic concentration ratio. The counts collected per projection between different scans and the SNR, contrast and resolution (FWHM) of two hot lesions were compared. As expected, the counts per projection increased when the camera had direct views of the heart and liver, but remained relatively constant at other angles. The SNR, contrast and FWHM were more affected by the insufficient sampling of the data by the large polar angles than by the cardiac and hepatic activity. An upper bound on polar tilt for each azimuthal position reduces the artifacts in the reconstructed images. Such trajectories were implemented to show artifact-free reconstructed images.