Robert P. Dickson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robert P. Dickson has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Carl Rrt Hinkson
Respiratory Care Department, Harborview Medical Center, University of Washington, Seattle, WA, USA
1 shared publication - Catherine Lee Hough
Department of Medicine University of Washington, Seattle, Washington
1 shared publication - David J. Pierson
Division of Pulmonary and Critical Care Medicine, Harborview Medical Center, 325 Ninth Avenue, Box 359762, Seattle, WA 98104, USA
1 shared publication - David L. Hotchkin1 shared publication
- Janet Regan-Baggs
Department of Nursing, University of Washington, Seattle, WA USA
1 shared publication - Lewis Rubinson
National Disaster Medical System, 409 C Street, Suite 330, Washington, DC 20224, USA
1 shared publication
Latest Publications
- Open Access
- 1 October 2014
- Published by Springer Nature in BMC Anesthesiology
- Vol. 14 (1) , 84
Medical intensive care unit clinician attitudes and perceived barriers towards early mobilization of critically ill patients: a cross-sectional survey study
Early mobilization (EM) of patients on mechanical ventilation (MV) is shown to improve outcomes after critical illness. Little is known regarding clinician knowledge of EM or multi-disciplinary barriers to use of EM in the intensive care unit (ICU). The goal of this study was to assess clinician knowledge regarding EM and identify barriers to its provision. Simultaneous cross-sectional surveys of medical ICU (MICU) nurses (RN)/physical therapists (PT) respondents and physician (MD) respondents in a single MICU at an academic hospital in Seattle, WA in 2010–2011. Responses were indicated on a 5 point Likert scale and reported as proportion of respondents agreeing or disagreeing. Chi-square testing and Fisher’s exact testing was performed to determine whether responses differed by duration of employment or prior EM experience. A total of 120 clinicians responded to the survey (91 MDs (response rate 82% (91/111)), 17 RNs (response rate 22%, (17/78)), and 12 PTs (response rate 86%, (12/14)), overall response rate 86%). Most clinicians indicated knowledge regarding benefits of EM. More attending physicians reported knowledge of EM benefits, but also that risks of EM outweigh the benefits compared to trainees (p = 0.02 and 0.01). Clinicians across disciplines reported near universal agreement to use of EM for patients on MV, while the minority reported agreement to EM for patients on vasoactive agents. The most frequently reported cross-disciplinary barriers to EM were staffing and time. Risk of self-injury and excess work stress were indicated as barriers by RN and PT respondents. MICU clinicians, at our institution, reported knowledge of EM in the ICU. Staffing and clinician time were frequently identified cross-disciplinary barriers. Risk of self-injury and excess work stress were frequently reported RN and PT barriers.
- 1 October 2014
- Published by Springer Nature in BMC Anesthesiology
- Vol. 14 (1) , 84
Open AccessMedical intensive care unit clinician attitudes and perceived barriers towards early mobilization of critically ill patients: a cross-sectional survey study
Early mobilization (EM) of patients on mechanical ventilation (MV) is shown to improve outcomes after critical illness. Little is known regarding clinician knowledge of EM or multi-disciplinary barriers to use of EM in the intensive care unit (ICU). The goal of this study was to assess clinician knowledge regarding EM and identify barriers to its provision. Simultaneous cross-sectional surveys of medical ICU (MICU) nurses (RN)/physical therapists (PT) respondents and physician (MD) respondents in a single MICU at an academic hospital in Seattle, WA in 2010–2011. Responses were indicated on a 5 point Likert scale and reported as proportion of respondents agreeing or disagreeing. Chi-square testing and Fisher’s exact testing was performed to determine whether responses differed by duration of employment or prior EM experience. A total of 120 clinicians responded to the survey (91 MDs (response rate 82% (91/111)), 17 RNs (response rate 22%, (17/78)), and 12 PTs (response rate 86%, (12/14)), overall response rate 86%). Most clinicians indicated knowledge regarding benefits of EM. More attending physicians reported knowledge of EM benefits, but also that risks of EM outweigh the benefits compared to trainees (p = 0.02 and 0.01). Clinicians across disciplines reported near universal agreement to use of EM for patients on MV, while the minority reported agreement to EM for patients on vasoactive agents. The most frequently reported cross-disciplinary barriers to EM were staffing and time. Risk of self-injury and excess work stress were indicated as barriers by RN and PT respondents. MICU clinicians, at our institution, reported knowledge of EM in the ICU. Staffing and clinician time were frequently identified cross-disciplinary barriers. Risk of self-injury and excess work stress were frequently reported RN and PT barriers.
- 1 April 2013
- Published by SAGE Publications in Respiratory Care
- Vol. 58 (4) , 712-714
Mechanical Ventilation of Patients With and Without ARDS: How Far Have We Come?
Nearly 13 years ago, the publication of results from the ARDS Network's ARMA trial revealed an 8.8% absolute mortality reduction in patients with acute lung injury (ALI)/ARDS receiving a low tidal volume ventilation strategy.[1][1] One might have guessed at the time that such unambiguous benefit
- 1 April 2013
- Published by SAGE Publications in Respiratory Care
- Vol. 58 (4) , 712-714
Mechanical Ventilation of Patients With and Without ARDS: How Far Have We Come?
Nearly 13 years ago, the publication of results from the ARDS Network's ARMA trial revealed an 8.8% absolute mortality reduction in patients with acute lung injury (ALI)/ARDS receiving a low tidal volume ventilation strategy.[1][1] One might have guessed at the time that such unambiguous benefit
- 1 March 2011
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 39 (3) , 527-532
A porcine model for initial surge mechanical ventilator assessment and evaluation of two limited-function ventilators*
Objectives: To adapt an animal model of acute lung injury for use as a standard protocol for a screening initial evaluation of limited function, or “surge,” ventilators for use in mass casualty scenarios. Design: Prospective, experimental animal study. Setting: University research laboratory. Subjects: Twelve adult pigs. Interventions: Twelve spontaneously breathing pigs (six in each group) were subjected to acute lung injury/acute respiratory distress syndrome via pulmonary artery infusion of oleic acid. After development of respiratory failure, animals were mechanically ventilated with a limited-function ventilator (simplified automatic ventilator [SAVe] I or II; Automedx, Germantown, MD) for 1 hr or until the ventilator could not support the animal. The limited-function ventilator was then exchanged for a full-function ventilator (Servo 900C; Siemens-Elema, Solna, Sweden). Measurements and Main Results: Reliable and reproducible levels of acute lung injury/acute respiratory distress syndrome were induced. The SAVe I was unable to adequately oxygenate five animals with Pao2 (52.0 ± 11.1 torr) compared to the Servo (106.0 ± 25.6 torr; p = .002). The SAVe II was able to oxygenate and ventilate all six animals for 1 hr with no difference in Pao2 (141.8 ± 169.3 torr) compared to the Servo (158.3 ± 167.7 torr). Conclusions: We describe a novel in vivo model of acute lung injury/acute respiratory distress syndrome that can be used to initially screen limited-function ventilators considered for mass respiratory failure stockpiles and that is intended to be combined with additional studies to definitively assess appropriateness for mass respiratory failure. Specifically, during this study we demonstrate that the SAVe I ventilator is unable to provide sufficient gas exchange, whereas the SAVe II, with several more functions, was able to support the same level of hypoxemic respiratory failure secondary to acute lung injury/acute respiratory distress syndrome for 1 hr.
- 1 March 2011
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 39 (3) , 527-532
A porcine model for initial surge mechanical ventilator assessment and evaluation of two limited-function ventilators*
Objectives: To adapt an animal model of acute lung injury for use as a standard protocol for a screening initial evaluation of limited function, or “surge,” ventilators for use in mass casualty scenarios. Design: Prospective, experimental animal study. Setting: University research laboratory. Subjects: Twelve adult pigs. Interventions: Twelve spontaneously breathing pigs (six in each group) were subjected to acute lung injury/acute respiratory distress syndrome via pulmonary artery infusion of oleic acid. After development of respiratory failure, animals were mechanically ventilated with a limited-function ventilator (simplified automatic ventilator [SAVe] I or II; Automedx, Germantown, MD) for 1 hr or until the ventilator could not support the animal. The limited-function ventilator was then exchanged for a full-function ventilator (Servo 900C; Siemens-Elema, Solna, Sweden). Measurements and Main Results: Reliable and reproducible levels of acute lung injury/acute respiratory distress syndrome were induced. The SAVe I was unable to adequately oxygenate five animals with Pao2 (52.0 ± 11.1 torr) compared to the Servo (106.0 ± 25.6 torr; p = .002). The SAVe II was able to oxygenate and ventilate all six animals for 1 hr with no difference in Pao2 (141.8 ± 169.3 torr) compared to the Servo (158.3 ± 167.7 torr). Conclusions: We describe a novel in vivo model of acute lung injury/acute respiratory distress syndrome that can be used to initially screen limited-function ventilators considered for mass respiratory failure stockpiles and that is intended to be combined with additional studies to definitively assess appropriateness for mass respiratory failure. Specifically, during this study we demonstrate that the SAVe I ventilator is unable to provide sufficient gas exchange, whereas the SAVe II, with several more functions, was able to support the same level of hypoxemic respiratory failure secondary to acute lung injury/acute respiratory distress syndrome for 1 hr.