Synho Do
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Synho Do has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Hiroyuki Yoshida
D Imaging Research, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, USA
2 shared publications - Janne Näppi
Massachusetts General Hospital (United States)
2 shared publications Anand K. Singh
1 shared publication- Anders Persson
Department of Radiology and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden; Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
1 shared publication Anuradha S. Shenoy-Bhangle
1 shared publication- Atul Padole
Department of Radiology, Massachusetts General Hospital, Boston, MA 02114, USA
1 shared publication
Latest Publications
- 1 January 2014
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 38 (1) , 117-122
Preliminary Results
The objective of this study was to compare image quality for abdominal computed tomographic (CT) images acquired at 200 and 50 mA s and reconstructed with image-based iterative reconstruction. In this institutional review board-approved prospective study, 22 patients (mean [SD] age, 64.3 [14.4] years; male-female ratio, 12:10) gave informed consent for acquisition of additional abdominal CT images on 64-slice multi-detector CT (MDCT) (Siemens Definition Flash). Standard-dose images were acquired at 200 quality reference mA s, whereas low-dose images were acquired at 50 mA s (all series: 120 kV; 5-mm section thickness; pitch, 0.9:1). The low-dose images were reconstructed with a nonlinear 3-dimensional iterative image reconstruction (3D-IIR) (SafeCT; MedicVision, Tirat Carmel, Israel) (4 settings, namely, A1, A2, A3, and A4) and were assessed by 3 abdominal radiologists for lesion detection, image noise, and visibility of small structures. CATPHAN 500 was scanned at the respective doses to obtain noise spectral density and modulation transfer function. Subjective image noise was unacceptable at 50-mA s filtered back projection and improved to average in 50-mA s A1 and minimal or no noise in 50-mA s A4. However, the visibility of small structures was similar to standard-dose filtered back projection images on 50-mA s A2. Objective image noise was reduced to 66% for the 50-mA s 3D-IIR images (9.08 [2.3]/26.75 [6.8]). The modulation transfer function curve demonstrated resolution improvement in the low-dose images with the 3D-IIR technique, whereas the noise spectral density curve confirmed noise suppression in the 50-mA s 3D-IIR images. Three-dimensional iterative image reconstruction helps to lower image noise without affecting the visibility of small structures at "moderate" settings. Diagnostically acceptable abdominal CT examinations can be acquired at 75% lower-radiation dose with the help of the image-based iterative reconstruction technique.
- 1 January 2014
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 38 (1) , 117-122
Preliminary Results
The objective of this study was to compare image quality for abdominal computed tomographic (CT) images acquired at 200 and 50 mA s and reconstructed with image-based iterative reconstruction. In this institutional review board-approved prospective study, 22 patients (mean [SD] age, 64.3 [14.4] years; male-female ratio, 12:10) gave informed consent for acquisition of additional abdominal CT images on 64-slice multi-detector CT (MDCT) (Siemens Definition Flash). Standard-dose images were acquired at 200 quality reference mA s, whereas low-dose images were acquired at 50 mA s (all series: 120 kV; 5-mm section thickness; pitch, 0.9:1). The low-dose images were reconstructed with a nonlinear 3-dimensional iterative image reconstruction (3D-IIR) (SafeCT; MedicVision, Tirat Carmel, Israel) (4 settings, namely, A1, A2, A3, and A4) and were assessed by 3 abdominal radiologists for lesion detection, image noise, and visibility of small structures. CATPHAN 500 was scanned at the respective doses to obtain noise spectral density and modulation transfer function. Subjective image noise was unacceptable at 50-mA s filtered back projection and improved to average in 50-mA s A1 and minimal or no noise in 50-mA s A4. However, the visibility of small structures was similar to standard-dose filtered back projection images on 50-mA s A2. Objective image noise was reduced to 66% for the 50-mA s 3D-IIR images (9.08 [2.3]/26.75 [6.8]). The modulation transfer function curve demonstrated resolution improvement in the low-dose images with the 3D-IIR technique, whereas the noise spectral density curve confirmed noise suppression in the 50-mA s 3D-IIR images. Three-dimensional iterative image reconstruction helps to lower image noise without affecting the visibility of small structures at "moderate" settings. Diagnostically acceptable abdominal CT examinations can be acquired at 75% lower-radiation dose with the help of the image-based iterative reconstruction technique.
- 31 October 2013
- Published by Elsevier in Academic Radiology
- Vol. 20 (10) , 1301-1305
A Novel Analysis Algorithm for Potential Quantitative Assessment of Myocardial Computed Tomography Perfusion
- 31 October 2013
- Published by Elsevier in Academic Radiology
- Vol. 20 (10) , 1301-1305
A Novel Analysis Algorithm for Potential Quantitative Assessment of Myocardial Computed Tomography Perfusion
- 1 January 2013
- Published by Springer Nature in Lecture Notes in Computer Science
- Vol. 8198, 73-80
Computer-Aided Detection of Colorectal Lesions with Super-Resolution CT Colonography: Pilot Evaluation
Reliable computer-aided detection (CADe) of small polyps and flat lesions is limited by the relatively low image resolution of computed tomographic colonography (CTC). We developed a sinogram-based super-resolution (SR) method to enhance the images of lesion candidates detected by CADe. First, CADe is used to detect lesion candidates at high sensitivity from conventional CTC images. Next, the signal patterns of the lesion candidates are enhanced in sinogram domain by use of non-uniform compressive sampling and iterative reconstruction to produce SR images of the lesion candidates. For pilot evaluation, an anthropomorphic phantom including simulated lesions was filled partially with fecal tagging and scanned by use of a CT scanner. A fully automated CADe scheme was used to detect lesion candidates in the images reconstructed at conventional 0.61-mm and at 0.10-mm SR image resolution. The proof-of-concept results indicate that the SR method has potential to reduce the number of FP CADe detections below that obtainable with the conventional CTC imaging technology.
- 1 January 2013
- Published by Springer Nature in Lecture Notes in Computer Science
- Vol. 8198, 73-80
Computer-Aided Detection of Colorectal Lesions with Super-Resolution CT Colonography: Pilot Evaluation
Reliable computer-aided detection (CADe) of small polyps and flat lesions is limited by the relatively low image resolution of computed tomographic colonography (CTC). We developed a sinogram-based super-resolution (SR) method to enhance the images of lesion candidates detected by CADe. First, CADe is used to detect lesion candidates at high sensitivity from conventional CTC images. Next, the signal patterns of the lesion candidates are enhanced in sinogram domain by use of non-uniform compressive sampling and iterative reconstruction to produce SR images of the lesion candidates. For pilot evaluation, an anthropomorphic phantom including simulated lesions was filled partially with fecal tagging and scanned by use of a CT scanner. A fully automated CADe scheme was used to detect lesion candidates in the images reconstructed at conventional 0.61-mm and at 0.10-mm SR image resolution. The proof-of-concept results indicate that the SR method has potential to reduce the number of FP CADe detections below that obtainable with the conventional CTC imaging technology.
- 1 January 2013
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 99-106
Iterative Reconstruction for Ultra-Low-Dose Laxative-Free CT Colonography
- 1 January 2013
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 99-106
Iterative Reconstruction for Ultra-Low-Dose Laxative-Free CT Colonography
- Open Access
- 1 January 2012
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2012, 1-7
Automated Quantification of Pneumothorax in CT
An automated, computer-aided diagnosis (CAD) algorithm for the quantification of pneumothoraces from Multidetector Computed Tomography (MDCT) images has been developed. Algorithm performance was evaluated through comparison to manual segmentation by expert radiologists. A combination of two-dimensional and three-dimensional processing techniques was incorporated to reduce required processing time by two-thirds (as compared to similar techniques). Volumetric measurements on relative pneumothorax size were obtained and the overall performance of the automated method shows an average error of just below 1%.
- 1 January 2012
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2012, 1-7
Open AccessAutomated Quantification of Pneumothorax in CT
An automated, computer-aided diagnosis (CAD) algorithm for the quantification of pneumothoraces from Multidetector Computed Tomography (MDCT) images has been developed. Algorithm performance was evaluated through comparison to manual segmentation by expert radiologists. A combination of two-dimensional and three-dimensional processing techniques was incorporated to reduce required processing time by two-thirds (as compared to similar techniques). Volumetric measurements on relative pneumothorax size were obtained and the overall performance of the automated method shows an average error of just below 1%.