Atul Padole
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Atul Padole has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Mannudeep K. Kalra
Department of Radiology, Massachusetts General Hospital, Boston, MA 02114, USA
5 shared publications Sarabjeet Singh
Thoracic Division, Imaging Department, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
5 shared publications- Ranish Deedar Ali Khawaja
MGH Imaging, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
4 shared publications Diego Lira
Atul Padole, Nisha Sainani, Diego Lira, Ranish Deedar Ali Khawaja, Sarvenaz Pourjabbar, Roberto Lo Gullo, Alexi Otrakji, Mannudeep K Kalra, Department of Radiology, Massachusetts General Hospital, Boston, MA 02114, United States
3 shared publicationsMannudeep K. Kalra
Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114
3 shared publicationsRanish Deedar Ali Khawaja
Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114
3 shared publications
Latest Publications
- Open Access
Diffuse Lung Metastases in EGFR-Mutant Non-Small Cell Lung Cancer
Diffuse lung metastases have been reported in non-small cell lung cancer (NSCLC) harboring epidermal growth factor receptor (EGFR) mutations. The purpose of our study was to compare the incidence of diffuse lung metastases in EGFR-mutant NSCLC and EGFR-wild type NSCLC and to assess other imaging features that may be associated with diffuse lung metastases in EGFR-mutant NSCLC. Two radiologists retrospectively reviewed pre-treatment imaging of metastatic NSCLC cases with known EGFR mutation status. We assessed the imaging features of the primary tumor and patterns of metastases. The cohort consisted of 217 patients (117 EGFR-mutant, 100 EGFR wild-type). Diffuse lung metastasis was significantly more common in EGFR-mutant NSCLC compared with wild-type (18% vs. 3%, p < 0.01). Among the EGFR-mutant group, diffuse lung metastases were inversely correlated with the presence of a nodule greater than 6 mm other than the primary lung lesion (OR: 0.13, 95% CI: 0.04–0.41, p < 0.01). EGFR mutations in NSCLC are associated with increased frequency of diffuse lung metastases. The presence of diffuse lung metastases in EGFR-mutant NSCLC is also associated with a decreased presence of other larger discrete lung metastases. EGFR mutations in NSCLC should be suspected in the setting of a dominant primary lung mass associated with diffuse lung metastases.
Open AccessDiffuse Lung Metastases in EGFR-Mutant Non-Small Cell Lung Cancer
Diffuse lung metastases have been reported in non-small cell lung cancer (NSCLC) harboring epidermal growth factor receptor (EGFR) mutations. The purpose of our study was to compare the incidence of diffuse lung metastases in EGFR-mutant NSCLC and EGFR-wild type NSCLC and to assess other imaging features that may be associated with diffuse lung metastases in EGFR-mutant NSCLC. Two radiologists retrospectively reviewed pre-treatment imaging of metastatic NSCLC cases with known EGFR mutation status. We assessed the imaging features of the primary tumor and patterns of metastases. The cohort consisted of 217 patients (117 EGFR-mutant, 100 EGFR wild-type). Diffuse lung metastasis was significantly more common in EGFR-mutant NSCLC compared with wild-type (18% vs. 3%, p < 0.01). Among the EGFR-mutant group, diffuse lung metastases were inversely correlated with the presence of a nodule greater than 6 mm other than the primary lung lesion (OR: 0.13, 95% CI: 0.04–0.41, p < 0.01). EGFR mutations in NSCLC are associated with increased frequency of diffuse lung metastases. The presence of diffuse lung metastases in EGFR-mutant NSCLC is also associated with a decreased presence of other larger discrete lung metastases. EGFR mutations in NSCLC should be suspected in the setting of a dominant primary lung mass associated with diffuse lung metastases.
- Open Access
- 10 June 2019
- Published by Springer Nature in Cancer Imaging
- Vol. 19 (1) , 1-8
Predicting malignant potential of subsolid nodules: can radiomics preempt longitudinal follow up CT?
To assess if radiomics can differentiate benign and malignant subsolid lung nodules (SSNs) on baseline or follow up chest CT examinations. If radiomics can differentiate between benign and malignant subsolid lung nodules, the clinical implications are shorter follow up CT imaging and early recognition of lung adenocarcinoma on imaging. The IRB approved retrospective study included 36 patients (mean age 69 ± 8 years; 5 males, 31 females) with 108 SSNs (31benign, 77 malignant) who underwent follow up chest CT for evaluation of indeterminate SSN. All SSNs were identified on both baseline and follow up chest CT. DICOM CT images were deidentified and exported into the open access 3D Slicer software (version 4.7) to obtain radiomic features. Logistic regression analyses and receiver operating characteristic (ROC) curves for various quantitative parameters were generated with SPSS statistical software. Only 2/92 radiomic features (cluster shade and surface volume ratio) enabled differentiation between malignant and benign SSN on baseline chest CT (P = 0.01 and 0.03) with moderate accuracy [AUC 0.624 (0.505–0.743)]. On follow-up CT, 52/92 radiomic features were significantly different between benign and malignant SSN (P: 0.04 - < 0.0001) with improved accuracy [AUC: 0.708 (0.605–0.811), P = 0.04 - < 0.0001]. Radiomics of benign SSN were stable over time, whereas 63/92 radiomic features of malignant SSNs changed significantly between the baseline and follow up chest CT (P: 0.04 - < 0.0001). Temporal changes in radiomic features of subsolid lung nodules favor malignant etiology over benign. The change in radiomics features of subsolid lung nodules can allow shorter follow up CT imaging and early recognition of lung adenocarcinoma on imaging. Radiomic features have limited application in differentiating benign and early malignant SSN on baseline chest CT.
- 10 June 2019
- Published by Springer Nature in Cancer Imaging
- Vol. 19 (1) , 1-8
Open AccessPredicting malignant potential of subsolid nodules: can radiomics preempt longitudinal follow up CT?
To assess if radiomics can differentiate benign and malignant subsolid lung nodules (SSNs) on baseline or follow up chest CT examinations. If radiomics can differentiate between benign and malignant subsolid lung nodules, the clinical implications are shorter follow up CT imaging and early recognition of lung adenocarcinoma on imaging. The IRB approved retrospective study included 36 patients (mean age 69 ± 8 years; 5 males, 31 females) with 108 SSNs (31benign, 77 malignant) who underwent follow up chest CT for evaluation of indeterminate SSN. All SSNs were identified on both baseline and follow up chest CT. DICOM CT images were deidentified and exported into the open access 3D Slicer software (version 4.7) to obtain radiomic features. Logistic regression analyses and receiver operating characteristic (ROC) curves for various quantitative parameters were generated with SPSS statistical software. Only 2/92 radiomic features (cluster shade and surface volume ratio) enabled differentiation between malignant and benign SSN on baseline chest CT (P = 0.01 and 0.03) with moderate accuracy [AUC 0.624 (0.505–0.743)]. On follow-up CT, 52/92 radiomic features were significantly different between benign and malignant SSN (P: 0.04 - < 0.0001) with improved accuracy [AUC: 0.708 (0.605–0.811), P = 0.04 - < 0.0001]. Radiomics of benign SSN were stable over time, whereas 63/92 radiomic features of malignant SSNs changed significantly between the baseline and follow up chest CT (P: 0.04 - < 0.0001). Temporal changes in radiomic features of subsolid lung nodules favor malignant etiology over benign. The change in radiomics features of subsolid lung nodules can allow shorter follow up CT imaging and early recognition of lung adenocarcinoma on imaging. Radiomic features have limited application in differentiating benign and early malignant SSN on baseline chest CT.
- 1 March 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1071) , 20160625
Assessment of chest CT at CTDIvol less than 1 mGy with iterative reconstruction techniques
Objective: To assess the image quality of chest CT reconstructed with image-based iterative reconstruction (SafeCT; MedicVision®, Tirat Carmel, Israel), adaptive statistical iterative reconstruction (ASIR; GE Healthcare, Waukesha, WI) and model-based iterative reconstruction (MBIR; GE Healthcare, Waukesha, WI) techniques at CT dose index volume (CTDIvol) <1 mGy. Methods: In an institutional review board-approved study, 25 patients gave written informed consent for acquisition of three reduced dose (0.25-, 0.4- and 0.8-mGy) chest CT after standard of care CT (8 mGy) on a 64-channel multidetector CT (MDCT) and reconstructed with SafeCT, ASIR and MBIR. Two board-certified thoracic radiologists evaluated images from the lowest to the highest dose of the reduced dose CT series and subsequently for standard of care CT. Results: Out of the 182 detected lesions, the missed lesions were 35 at 0.25, 24 at 0.4 and 9 at 0.8 mGy with SafeCT, ASIR and MBIR, respectively. The most missed lesions were non-calcified lung nodules (NCLNs) 25/112 (<5 mm) at 0.25, 18/112 (<5 mm) at 0.4 and 3/112 (<4 mm) at 0.8 mGy. There were 78%, 84% and 97% lung nodules detected at 0.25, 0.4 and 0.8 mGy, respectively regardless of iterative reconstruction techniques (IRTs), Most mediastinum structures were not sufficiently seen at 0.25–0.8 mGy. Conclusion: NCLNs can be missed in chest CT at CTDIvol of <1 mGy (0.25, 0.4 and 0.8 mGy) regardless of IRTs. The most lung nodules (97%) were detected at CTDIvol of 0.8 mGy. The most mediastinum structures were not sufficiently seen at 0.25–0.8 mGy. Advances in knowledge: NCLNs can be missed regardless of IRTs in chest CT at CTDIvol of <1 mGy. The performance of ASIR, SafeCT and MBIR was similar for lung nodule detection at 0.25, 0.4 and 0.8 mGy.
- 1 March 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1071) , 20160625
Assessment of chest CT at CTDIvol less than 1 mGy with iterative reconstruction techniques
Objective: To assess the image quality of chest CT reconstructed with image-based iterative reconstruction (SafeCT; MedicVision®, Tirat Carmel, Israel), adaptive statistical iterative reconstruction (ASIR; GE Healthcare, Waukesha, WI) and model-based iterative reconstruction (MBIR; GE Healthcare, Waukesha, WI) techniques at CT dose index volume (CTDIvol) <1 mGy. Methods: In an institutional review board-approved study, 25 patients gave written informed consent for acquisition of three reduced dose (0.25-, 0.4- and 0.8-mGy) chest CT after standard of care CT (8 mGy) on a 64-channel multidetector CT (MDCT) and reconstructed with SafeCT, ASIR and MBIR. Two board-certified thoracic radiologists evaluated images from the lowest to the highest dose of the reduced dose CT series and subsequently for standard of care CT. Results: Out of the 182 detected lesions, the missed lesions were 35 at 0.25, 24 at 0.4 and 9 at 0.8 mGy with SafeCT, ASIR and MBIR, respectively. The most missed lesions were non-calcified lung nodules (NCLNs) 25/112 (<5 mm) at 0.25, 18/112 (<5 mm) at 0.4 and 3/112 (<4 mm) at 0.8 mGy. There were 78%, 84% and 97% lung nodules detected at 0.25, 0.4 and 0.8 mGy, respectively regardless of iterative reconstruction techniques (IRTs), Most mediastinum structures were not sufficiently seen at 0.25–0.8 mGy. Conclusion: NCLNs can be missed in chest CT at CTDIvol of <1 mGy (0.25, 0.4 and 0.8 mGy) regardless of IRTs. The most lung nodules (97%) were detected at CTDIvol of 0.8 mGy. The most mediastinum structures were not sufficiently seen at 0.25–0.8 mGy. Advances in knowledge: NCLNs can be missed regardless of IRTs in chest CT at CTDIvol of <1 mGy. The performance of ASIR, SafeCT and MBIR was similar for lung nodule detection at 0.25, 0.4 and 0.8 mGy.
- 1 May 2016
- Published by Elsevier in Academic Radiology
- Vol. 23 (5) , 634-642
Comparison of Measured and Estimated CT Organ Doses for Modulated and Fixed Tube Current:
- 1 May 2016
- Published by Elsevier in Academic Radiology
- Vol. 23 (5) , 634-642
Comparison of Measured and Estimated CT Organ Doses for Modulated and Fixed Tube Current:
- Open Access
- 1 January 2016
- Published by Baishideng Publishing Group Inc. in World Journal of Radiology
- Vol. 8 (6) , 618-627
Assessment of sub-milli-sievert abdominal computed tomography with iterative reconstruction techniques of different vendors
Assessment of sub-milli-sievert abdominal computed tomography with iterative reconstruction techniques of different vendors
- 1 January 2016
- Published by Baishideng Publishing Group Inc. in World Journal of Radiology
- Vol. 8 (6) , 618-627
Open AccessAssessment of sub-milli-sievert abdominal computed tomography with iterative reconstruction techniques of different vendors
Assessment of sub-milli-sievert abdominal computed tomography with iterative reconstruction techniques of different vendors
- 1 June 2015
- Published by SAGE Publications in Acta Radiologica
- Vol. 56 (6) , 688-695
Dose reduction for chest CT: comparison of two iterative reconstruction techniques
Background: Lowering radiation dose in computed tomography (CT) scan results in low quality noisy images. Iterative reconstruction techniques are used currently to lower image noise and improve the quality of images. Purpose: To evaluate lesion detection and diagnostic acceptability of chest CT images acquired at CTDIvol of 1.8 mGy and processed with two different iterative reconstruction techniques. Material and Methods: Twenty-two patients (mean age, 60 ± 14 years; men, 13; women, 9; body mass index, 27.4 ± 6.5 kg/m2) gave informed consent for acquisition of low dose (LD) series in addition to the standard dose (SD) chest CT on a 128 - multidetector CT (MDCT). LD images were reconstructed with SafeCT C4, L1, and L2 settings, and Safire S1, S2, and S3 settings. Three thoracic radiologists assessed LD image series (S1, S2, S3, C4, L1, and L2) for lesion detection and comparison of lesion margin, visibility of normal structures, and diagnostic confidence with SD chest CT. Inter-observer agreement (kappa) was calculated. Results: Average CTDIvol was 6.4 ± 2.7 mGy and 1.8 ± 0.2 mGy for SD and LD series, respectively. No additional lesion was found in SD as compared to LD images. Visibility of ground-glass opacities and lesion margins, as well as normal structures visibility were not affected on LD. CT image visibility of major fissure and pericardium was not optimal in some cases ( n = 5). Objective image noise in some low dose images processed with SafeCT and Safire was similar to SD images ( P value > 0.5). Conclusion: Routine LD chest CT reconstructed with iterative reconstruction technique can provide similar diagnostic information in terms of lesion detection, margin, and diagnostic confidence as compared to SD, regardless of the iterative reconstruction settings.
- 1 June 2015
- Published by SAGE Publications in Acta Radiologica
- Vol. 56 (6) , 688-695
Dose reduction for chest CT: comparison of two iterative reconstruction techniques
Background: Lowering radiation dose in computed tomography (CT) scan results in low quality noisy images. Iterative reconstruction techniques are used currently to lower image noise and improve the quality of images. Purpose: To evaluate lesion detection and diagnostic acceptability of chest CT images acquired at CTDIvol of 1.8 mGy and processed with two different iterative reconstruction techniques. Material and Methods: Twenty-two patients (mean age, 60 ± 14 years; men, 13; women, 9; body mass index, 27.4 ± 6.5 kg/m2) gave informed consent for acquisition of low dose (LD) series in addition to the standard dose (SD) chest CT on a 128 - multidetector CT (MDCT). LD images were reconstructed with SafeCT C4, L1, and L2 settings, and Safire S1, S2, and S3 settings. Three thoracic radiologists assessed LD image series (S1, S2, S3, C4, L1, and L2) for lesion detection and comparison of lesion margin, visibility of normal structures, and diagnostic confidence with SD chest CT. Inter-observer agreement (kappa) was calculated. Results: Average CTDIvol was 6.4 ± 2.7 mGy and 1.8 ± 0.2 mGy for SD and LD series, respectively. No additional lesion was found in SD as compared to LD images. Visibility of ground-glass opacities and lesion margins, as well as normal structures visibility were not affected on LD. CT image visibility of major fissure and pericardium was not optimal in some cases ( n = 5). Objective image noise in some low dose images processed with SafeCT and Safire was similar to SD images ( P value > 0.5). Conclusion: Routine LD chest CT reconstructed with iterative reconstruction technique can provide similar diagnostic information in terms of lesion detection, margin, and diagnostic confidence as compared to SD, regardless of the iterative reconstruction settings.
- 1 January 2015
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 39 (4) , 462-467
Assessment of Filtered Back Projection, Adaptive Statistical, and Model-Based Iterative Reconstruction for Reduced Dose Abdominal Computed Tomography
To compare standard of care and reduced dose (RD) abdominal computed tomography (CT) images reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), model-based iterative reconstruction (MBIR) techniques. In an Institutional Review Board-approved, prospective clinical study, 28 patients (mean age 59 ± 13 years ), undergoing clinically indicated routine abdominal CT on a 64-channel multi-detector CT scanner, gave written informed consent for acquisition of an additional RD (<1 milli-Sievert) abdomen CT series. Sinogram data of RD series were reconstructed with FBP, ASIR, and MBIR and compared with FBP images of standard dose abdomen CT. Two radiologists performed randomized, independent, and blinded comparison for lesion detection, lesion margin, visibility of normal structures, and diagnostic confidence. Mean CT dose index volume was 10 ± 3.4 mGy and 1.3 ± 0.3 mGy for standard and RD CT, respectively. There were 73 "true positive" lesions detected on standard of care CT. Nine lesions (<8 mm in size) were missed on RD abdominal CT images which included liver lesions, liver cysts, kidney cysts, and paracolonic abscess. These lesions were missed regardless of patient size and types of iterative reconstruction techniques used for reconstruction of RD data sets. The visibility of lesion margin was suboptimal in (23/28) patients with RD FBP, (15/28) patients with RD ASIR, and (14/28) patients with RD MBIR compared to standard of care FBP images (P < 0.001). Diagnostic confidence for the assessment of lesions on RD images was suboptimal in most patients regardless of iterative reconstruction techniques. Clinically significant lesions (< 8 mm) can be missed on abdominal CT examinations acquired at a CT dose index volume of 1.3 mGy regardless of patients' size and reconstruction techniques (FBP, ASIR, and MBIR).
- 1 January 2015
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 39 (4) , 462-467
Assessment of Filtered Back Projection, Adaptive Statistical, and Model-Based Iterative Reconstruction for Reduced Dose Abdominal Computed Tomography
To compare standard of care and reduced dose (RD) abdominal computed tomography (CT) images reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), model-based iterative reconstruction (MBIR) techniques. In an Institutional Review Board-approved, prospective clinical study, 28 patients (mean age 59 ± 13 years ), undergoing clinically indicated routine abdominal CT on a 64-channel multi-detector CT scanner, gave written informed consent for acquisition of an additional RD (<1 milli-Sievert) abdomen CT series. Sinogram data of RD series were reconstructed with FBP, ASIR, and MBIR and compared with FBP images of standard dose abdomen CT. Two radiologists performed randomized, independent, and blinded comparison for lesion detection, lesion margin, visibility of normal structures, and diagnostic confidence. Mean CT dose index volume was 10 ± 3.4 mGy and 1.3 ± 0.3 mGy for standard and RD CT, respectively. There were 73 "true positive" lesions detected on standard of care CT. Nine lesions (<8 mm in size) were missed on RD abdominal CT images which included liver lesions, liver cysts, kidney cysts, and paracolonic abscess. These lesions were missed regardless of patient size and types of iterative reconstruction techniques used for reconstruction of RD data sets. The visibility of lesion margin was suboptimal in (23/28) patients with RD FBP, (15/28) patients with RD ASIR, and (14/28) patients with RD MBIR compared to standard of care FBP images (P < 0.001). Diagnostic confidence for the assessment of lesions on RD images was suboptimal in most patients regardless of iterative reconstruction techniques. Clinically significant lesions (< 8 mm) can be missed on abdominal CT examinations acquired at a CT dose index volume of 1.3 mGy regardless of patients' size and reconstruction techniques (FBP, ASIR, and MBIR).
- 1 January 2015
- Published by Elsevier in European Journal of Radiology
- Vol. 84 (1) , 2-10
Ultra-low dose abdominal MDCT: Using a knowledge-based Iterative Model Reconstruction technique for substantial dose reduction in a prospective clinical study
- 1 January 2015
- Published by Elsevier in European Journal of Radiology
- Vol. 84 (1) , 2-10
Ultra-low dose abdominal MDCT: Using a knowledge-based Iterative Model Reconstruction technique for substantial dose reduction in a prospective clinical study
- 1 October 2014
- Published by Elsevier in European Journal of Radiology
- Vol. 83 (10) , 1934-1944
Ultra low-dose chest CT using filtered back projection: Comparison of 80-, 100- and 120kVp protocols in a prospective randomized study
- 1 October 2014
- Published by Elsevier in European Journal of Radiology
- Vol. 83 (10) , 1934-1944
Ultra low-dose chest CT using filtered back projection: Comparison of 80-, 100- and 120kVp protocols in a prospective randomized study
- 1 July 2014
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 203 (1) , 118-122
What Is the Minimal Radiation Dose That Can Be Used for Detecting Pleural Effusion?
The objective of our study was to assess the effect of radiation dose reduction on the detection of pleural effusions, thickening, and calcifications. Forty-five human cadavers (mean age at death, 60 ± 17 [SD] years; male-female ratio, 29:16; mean body mass index, 29 ± 5.7 [SD] kg/m(2)) were scanned at seven different dose levels (CT Dose Index volume [CTDIvol] = 20, 12, 10, 6, 4, 2, and 0.8 mGy) on a 128-MDCT unit (Definition FLASH). Images were reconstructed at a 3-mm slice thickness and 2-mm increment with filtered back projection (FBP) technique. Two chest radiologists independently reviewed all image series for the detection of pleural effusion, pleural calcification, and adjacent parenchymal opacification from atelectasis or consolidation. Objective image noise was measured at each dose level on the pleural effusion using ImageJ software. Data analysis was performed with the Student t test and kappa test. Pleural effusions were seen in 39 of 45 cadavers on image series acquired at 2-20 mGy. Only 14 of 39 pleural effusions were identified at 0.8 mGy. Pleural effusions were not detected in 25 of 39 cadavers at 0.8 mGy because of photon starvation and increased image noise. Patient size was significantly larger in subjects with undetected pleural effusion than in those with detectable pleural effusion at 0.8 mGy (p < 0.01). Pleural calcifications and thickening (seen at 2-10 mGy images in three of three cadavers) were not identified on 0.8-mGy FBP images. On the other hand, adjacent parenchymal opacification could be assessed at all dose levels. The mean CT numbers of the pleural effusion were significantly lower on 0.8-mGy images than on images obtained at all other dose levels (-21 ± 55 [SD] vs 17.6 ± 19 HU, respectively) (p < 0.001). Pleural effusions, thickening, and calcifications can be seen on FBP images reconstructed at a CTDIvol as low as 2 mGy (32-cm body phantom). CT at 0.8 mGy may provide suboptimal information on very small pleural effusions, pleural thickening, and calcifications.
- 1 July 2014
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 203 (1) , 118-122
What Is the Minimal Radiation Dose That Can Be Used for Detecting Pleural Effusion?
The objective of our study was to assess the effect of radiation dose reduction on the detection of pleural effusions, thickening, and calcifications. Forty-five human cadavers (mean age at death, 60 ± 17 [SD] years; male-female ratio, 29:16; mean body mass index, 29 ± 5.7 [SD] kg/m(2)) were scanned at seven different dose levels (CT Dose Index volume [CTDIvol] = 20, 12, 10, 6, 4, 2, and 0.8 mGy) on a 128-MDCT unit (Definition FLASH). Images were reconstructed at a 3-mm slice thickness and 2-mm increment with filtered back projection (FBP) technique. Two chest radiologists independently reviewed all image series for the detection of pleural effusion, pleural calcification, and adjacent parenchymal opacification from atelectasis or consolidation. Objective image noise was measured at each dose level on the pleural effusion using ImageJ software. Data analysis was performed with the Student t test and kappa test. Pleural effusions were seen in 39 of 45 cadavers on image series acquired at 2-20 mGy. Only 14 of 39 pleural effusions were identified at 0.8 mGy. Pleural effusions were not detected in 25 of 39 cadavers at 0.8 mGy because of photon starvation and increased image noise. Patient size was significantly larger in subjects with undetected pleural effusion than in those with detectable pleural effusion at 0.8 mGy (p < 0.01). Pleural calcifications and thickening (seen at 2-10 mGy images in three of three cadavers) were not identified on 0.8-mGy FBP images. On the other hand, adjacent parenchymal opacification could be assessed at all dose levels. The mean CT numbers of the pleural effusion were significantly lower on 0.8-mGy images than on images obtained at all other dose levels (-21 ± 55 [SD] vs 17.6 ± 19 HU, respectively) (p < 0.001). Pleural effusions, thickening, and calcifications can be seen on FBP images reconstructed at a CTDIvol as low as 2 mGy (32-cm body phantom). CT at 0.8 mGy may provide suboptimal information on very small pleural effusions, pleural thickening, and calcifications.