Preliminary Results
Authors:
- Sarvenaz PourjabbarSPSarvenaz Pourjabbar
- Sarabjeet SinghSSSarabjeet Singh
- Anand K. SinghASAnand K. Singh
- Rocio P. JohnstonRJRocio P. Johnston
- Anuradha S. Shenoy-BhangleASAnuradha S. Shenoy-Bhangle
- Synho DoSDSynho Do
- Atul PadoleAPAtul Padole
- Michael A. BlakeMBMichael A. Blake
- Anders PerssonAPAnders Persson
- Mannudeep K. KalraMKMannudeep K. Kalra
- 1 January 2014
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 38 (1) , 117-122
Abstract
The objective of this study was to compare image quality for abdominal computed tomographic (CT) images acquired at 200 and 50 mA s and reconstructed with image-based iterative reconstruction. In this institutional review board-approved prospective study, 22 patients (mean [SD] age, 64.3 [14.4] years; male-female ratio, 12:10) gave informed consent for acquisition of additional abdominal CT images on 64-slice multi-detector CT (MDCT) (Siemens Definition Flash). Standard-dose images were acquired at 200 quality reference mA s, whereas low-dose images were acquired at 50 mA s (all series: 120 kV; 5-mm section thickness; pitch, 0.9:1). The low-dose images were reconstructed with a nonlinear 3-dimensional iterative image reconstruction (3D-IIR) (SafeCT; MedicVision, Tirat Carmel, Israel) (4 settings, namely, A1, A2, A3, and A4) and were assessed by 3 abdominal radiologists for lesion detection, image noise, and visibility of small structures. CATPHAN 500 was scanned at the respective doses to obtain noise spectral density and modulation transfer function. Subjective image noise was unacceptable at 50-mA s filtered back projection and improved to average in 50-mA s A1 and minimal or no noise in 50-mA s A4. However, the visibility of small structures was similar to standard-dose filtered back projection images on 50-mA s A2. Objective image noise was reduced to 66% for the 50-mA s 3D-IIR images (9.08 [2.3]/26.75 [6.8]). The modulation transfer function curve demonstrated resolution improvement in the low-dose images with the 3D-IIR technique, whereas the noise spectral density curve confirmed noise suppression in the 50-mA s 3D-IIR images. Three-dimensional iterative image reconstruction helps to lower image noise without affecting the visibility of small structures at "moderate" settings. Diagnostically acceptable abdominal CT examinations can be acquired at 75% lower-radiation dose with the help of the image-based iterative reconstruction technique.Keywords
This publication has 16 references indexed in Scilit:
- Abdominal CT With Model-Based Iterative Reconstruction (MBIR): Initial Results of a Prospective Trial Comparing Ultralow-Dose With Standard-Dose ImagingAmerican Journal of Roentgenology, 2012
- Comparison of Hybrid and Pure Iterative Reconstruction Techniques With Conventional Filtered Back ProjectionJournal of Computer Assisted Tomography, 2012
- Radiation Dose Reduction With Sinogram Affirmed Iterative Reconstruction Technique for Abdominal Computed TomographyJournal of Computer Assisted Tomography, 2012
- CT Radiation Dose Reduction by Modifying Primary FactorsJournal of the American College of Radiology, 2011
- Abdominal CT: Comparison of Adaptive Statistical Iterative and Filtered Back Projection Reconstruction TechniquesRadiology, 2010
- Low-Tube-Voltage, High-Tube-Current Multidetector Abdominal CT: Improved Image Quality and Decreased Radiation Dose with Adaptive Statistical Iterative Reconstruction Algorithm—Initial Clinical ExperienceRadiology, 2010
- Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility StudyAmerican Journal of Roentgenology, 2009
- Comparison of Angular and Combined Automatic Tube Current Modulation Techniques with Constant Tube Current CT of the Abdomen and PelvisAmerican Journal of Roentgenology, 2006
- Radiation Exposure and Projected Risks With Multidetector-Row Computed Tomography ScanningJournal of Computer Assisted Tomography, 2004
- Cancer risks attributable to low doses of ionizing radiation: Assessing what we really knowProceedings of the National Academy of Sciences of the United States of America, 2003