Nahar Singh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nahar Singh has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Daya Soni
CSIR-National Physical Laboratory, New Delhi, India
2 shared publications - Prabhat K Gupta
Analytical Chemistry Division, CSIR- National Physical Laboratory, Dr K. S. Krishnan Marg, New Delhi 110012, India
2 shared publications Rashmi
CSIR-National Physical Laboratory, Dr K.S. Krishnan Marg, New Delhi – 110012, India
2 shared publications- S Swarupa Tripathy
CSIR-National Physical Laboratory, Dr K.S. Krishnan Marg, New Delhi, 110012, India
2 shared publications S. Swarupa Tripathy
CSIR-National Physical Laboratory, New Delhi 110012, India
2 shared publications- Surinder Pal Singh
CSIR-National Physical Laboratory, New Delhi, India
2 shared publications
Latest Publications
- 1 May 2017
- Published by Elsevier in Journal of Environmental Sciences
- Vol. 55, 76-85
Study of cyanide removal from contaminated water using zinc peroxide nanomaterial
- 1 May 2017
- Published by Elsevier in Journal of Environmental Sciences
- Vol. 55, 76-85
Study of cyanide removal from contaminated water using zinc peroxide nanomaterial
- 17 March 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (11) , 3682-3688
A new, rugged, precise and accurate gravimetry method for the determination of silver in various silver materials
A new, rugged, precise and accurate gravimetric method has been developed for the determination of silver in various silver bearing materials. Several gravimetry and instrumental methods have been reported in the literature for silver determination, but the fire assay method E2295-03(2008) e1E 1335-08 reported in ASTM is the only standard test method accepted internationally. This method is cumbersome, time consuming, and only a well trained chemist can perform the test. In this method the determination of silver has been carried out as silver chloride. The silver chloride formed is highly hygroscopic and converts into silver metal on exposure to light, on keeping the silver chloride for up to a few hours to covert into metallic silver. But we do not consider this in our calculations, we calculate on the basis of silver chloride, so it may affect the final results. Considering these facts a gravimetry method has been developed, after reducing silver nitrate to metallic silver using hydroxylamine hydrochloride in ammoniacal medium. In the method proposed the metallic silver formed is non-hygroscopic and is stable for several months. A comparison study has also been carried out following the primary (gravimetry) method and the existing ASTM method. A primary method of measurement is a method having the highest metrological qualities, whose operation is completely described and understood in terms of SI units and whose results are accepted without reference to a standard of the same quantity. Gravimetry is a primary method, but parallel validation has been carried out by analyzing a certified reference material of silver procured from SCP Science, Canada. The formation of metallic silver and silver chloride has been confirmed by X-ray fluorescence and X-ray diffraction. The method has also been tested in the presence of several impurities of single or multi-elements, which is generally added to the silver metal. The calculation of uncertainty has also been done following the EURACHEM/GUM guideline. After the experiment it has been found that the uncertainty result mostly depends on the uncertainty due to repeatability, weighing balance and atomic mass of silver. On the basis of the proposed method and the ASTM method the purity of silver was found to be 99.841 ± 0.085% and 99.746 ± 0.105%, whereas the recovery of silver using the SCP reference standard was found to be 99.971 ± 0.20% and 99.941 ± 0.202% respectively with 95% confidence level (k = 2). The method proposed is highly reproducible, rugged and can be used for accurate and precise determination of silver in various silver materials.
- 17 March 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (11) , 3682-3688
A new, rugged, precise and accurate gravimetry method for the determination of silver in various silver materials
A new, rugged, precise and accurate gravimetric method has been developed for the determination of silver in various silver bearing materials. Several gravimetry and instrumental methods have been reported in the literature for silver determination, but the fire assay method E2295-03(2008) e1E 1335-08 reported in ASTM is the only standard test method accepted internationally. This method is cumbersome, time consuming, and only a well trained chemist can perform the test. In this method the determination of silver has been carried out as silver chloride. The silver chloride formed is highly hygroscopic and converts into silver metal on exposure to light, on keeping the silver chloride for up to a few hours to covert into metallic silver. But we do not consider this in our calculations, we calculate on the basis of silver chloride, so it may affect the final results. Considering these facts a gravimetry method has been developed, after reducing silver nitrate to metallic silver using hydroxylamine hydrochloride in ammoniacal medium. In the method proposed the metallic silver formed is non-hygroscopic and is stable for several months. A comparison study has also been carried out following the primary (gravimetry) method and the existing ASTM method. A primary method of measurement is a method having the highest metrological qualities, whose operation is completely described and understood in terms of SI units and whose results are accepted without reference to a standard of the same quantity. Gravimetry is a primary method, but parallel validation has been carried out by analyzing a certified reference material of silver procured from SCP Science, Canada. The formation of metallic silver and silver chloride has been confirmed by X-ray fluorescence and X-ray diffraction. The method has also been tested in the presence of several impurities of single or multi-elements, which is generally added to the silver metal. The calculation of uncertainty has also been done following the EURACHEM/GUM guideline. After the experiment it has been found that the uncertainty result mostly depends on the uncertainty due to repeatability, weighing balance and atomic mass of silver. On the basis of the proposed method and the ASTM method the purity of silver was found to be 99.841 ± 0.085% and 99.746 ± 0.105%, whereas the recovery of silver using the SCP reference standard was found to be 99.971 ± 0.20% and 99.941 ± 0.202% respectively with 95% confidence level (k = 2). The method proposed is highly reproducible, rugged and can be used for accurate and precise determination of silver in various silver materials.
- Open Access
- 11 September 2013
- Published by Springer Nature in SpringerPlus
- Vol. 2 (1) , 453
Quantifying uncertainty in measurement of mercury in suspended particulate matter by cold vapor technique using atomic absorption spectrometry with hydride generator
As a result of rapid industrialization several chemical forms of organic and inorganic mercury are constantly introduced to the environment and affect humans and animals directly. All forms of mercury have toxic effects; therefore accurate measurement of mercury is of prime importance especially in suspended particulate matter (SPM) collected through high volume sampler (HVS). In the quantification of mercury in SPM samples several steps are involved from sampling to final result. The quality, reliability and confidence level of the analyzed data depends upon the measurement uncertainty of the whole process. Evaluation of measurement uncertainty of results is one of the requirements of the standard ISO/IEC 17025:2005 (European Standard EN IS/ISO/IEC 17025:2005, issue1:1-28, 2006). In the presented study the uncertainty estimation in mercury determination in suspended particulate matter (SPM) has been carried out using cold vapor Atomic Absorption Spectrometer-Hydride Generator (AAS-HG) technique followed by wet chemical digestion process. For the calculation of uncertainty, we have considered many general potential sources of uncertainty. After the analysis of data of seven diverse sites of Delhi, it has been concluded that the mercury concentration varies from 1.59 ± 0.37 to 14.5 ± 2.9 ng/m3 with 95% confidence level (k = 2).
- 11 September 2013
- Published by Springer Nature in SpringerPlus
- Vol. 2 (1) , 453
Open AccessQuantifying uncertainty in measurement of mercury in suspended particulate matter by cold vapor technique using atomic absorption spectrometry with hydride generator
As a result of rapid industrialization several chemical forms of organic and inorganic mercury are constantly introduced to the environment and affect humans and animals directly. All forms of mercury have toxic effects; therefore accurate measurement of mercury is of prime importance especially in suspended particulate matter (SPM) collected through high volume sampler (HVS). In the quantification of mercury in SPM samples several steps are involved from sampling to final result. The quality, reliability and confidence level of the analyzed data depends upon the measurement uncertainty of the whole process. Evaluation of measurement uncertainty of results is one of the requirements of the standard ISO/IEC 17025:2005 (European Standard EN IS/ISO/IEC 17025:2005, issue1:1-28, 2006). In the presented study the uncertainty estimation in mercury determination in suspended particulate matter (SPM) has been carried out using cold vapor Atomic Absorption Spectrometer-Hydride Generator (AAS-HG) technique followed by wet chemical digestion process. For the calculation of uncertainty, we have considered many general potential sources of uncertainty. After the analysis of data of seven diverse sites of Delhi, it has been concluded that the mercury concentration varies from 1.59 ± 0.37 to 14.5 ± 2.9 ng/m3 with 95% confidence level (k = 2).
- Open Access
- 26 June 2013
- Published by Springer Nature in BMC Chemistry
- Vol. 7 (1) , 108
Evaluation of purity with its uncertainty value in high purity lead stick by conventional and electro-gravimetric methods
A conventional gravimetry and electro-gravimetry study has been carried out for the precise and accurate purity determination of lead (Pb) in high purity lead stick and for preparation of reference standard. Reference materials are standards containing a known amount of an analyte and provide a reference value to determine unknown concentrations or to calibrate analytical instruments. A stock solution of approximate 2 kg has been prepared after dissolving approximate 2 g of Pb stick in 5% ultra pure nitric acid. From the stock solution five replicates of approximate 50 g have been taken for determination of purity by each method. The Pb has been determined as PbSO4 by conventional gravimetry, as PbO2 by electro gravimetry. The percentage purity of the metallic Pb was calculated accordingly from PbSO4 and PbO2. On the basis of experimental observations it has been concluded that by conventional gravimetry and electro-gravimetry the purity of Pb was found to be 99.98 ± 0.24 and 99.97 ± 0.27 g/100 g and on the basis of Pb purity the concentration of reference standard solutions were found to be 1000.88 ± 2.44 and 1000.81 ± 2.68 mg kg-1 respectively with 95% confidence level (k = 2). The uncertainty evaluation has also been carried out in Pb determination following EURACHEM/GUM guidelines. The final analytical results quantifying uncertainty fulfills this requirement and gives a measure of the confidence level of the concerned laboratory. Gravimetry is the most reliable technique in comparison to titremetry and instrumental method and the results of gravimetry are directly traceable to SI unit. Gravimetric analysis, if methods are followed carefully, provides for exceedingly precise analysis. In classical gravimetry the major uncertainties are due to repeatability but in electro-gravimetry several other factors also affect the final results.
- 26 June 2013
- Published by Springer Nature in BMC Chemistry
- Vol. 7 (1) , 108
Open AccessEvaluation of purity with its uncertainty value in high purity lead stick by conventional and electro-gravimetric methods
A conventional gravimetry and electro-gravimetry study has been carried out for the precise and accurate purity determination of lead (Pb) in high purity lead stick and for preparation of reference standard. Reference materials are standards containing a known amount of an analyte and provide a reference value to determine unknown concentrations or to calibrate analytical instruments. A stock solution of approximate 2 kg has been prepared after dissolving approximate 2 g of Pb stick in 5% ultra pure nitric acid. From the stock solution five replicates of approximate 50 g have been taken for determination of purity by each method. The Pb has been determined as PbSO4 by conventional gravimetry, as PbO2 by electro gravimetry. The percentage purity of the metallic Pb was calculated accordingly from PbSO4 and PbO2. On the basis of experimental observations it has been concluded that by conventional gravimetry and electro-gravimetry the purity of Pb was found to be 99.98 ± 0.24 and 99.97 ± 0.27 g/100 g and on the basis of Pb purity the concentration of reference standard solutions were found to be 1000.88 ± 2.44 and 1000.81 ± 2.68 mg kg-1 respectively with 95% confidence level (k = 2). The uncertainty evaluation has also been carried out in Pb determination following EURACHEM/GUM guidelines. The final analytical results quantifying uncertainty fulfills this requirement and gives a measure of the confidence level of the concerned laboratory. Gravimetry is the most reliable technique in comparison to titremetry and instrumental method and the results of gravimetry are directly traceable to SI unit. Gravimetric analysis, if methods are followed carefully, provides for exceedingly precise analysis. In classical gravimetry the major uncertainties are due to repeatability but in electro-gravimetry several other factors also affect the final results.
- 10 September 2012
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 32 (4) , 1023-1029
A process for the selective removal of arsenic from contaminated water using acetate functionalized zinc oxide nanomaterials
This research article deals with the uptake of arsenic from contaminated water using acetate functionalized zinc oxide (ZnO) nanomaterials. The ZnO nanomaterials of various sizes (6–60 nm) have been synthesized following different wet chemical routes. The arsenic removal efficacy of acetate functionalized ZnO nanomaterials was carried out at different pH and time interval. It has been concluded from the study that ZnO nanomaterials (<60 nm) prepared by zinc acetate precursor effectively removes arsenic, while ZnO of same size prepared from zinc chloride, zinc nitrate, zinc sulphate precursor could not remove arsenic considerably. However, ZnO of same size synthesized using other than zinc acetate precursor and functionalized with acetate ions removes arsenic effectively. It is also proposed that acetate ions over the surface of ZnO adsorb arsenic by an oxo‐coordination mechanism and purifies water up to permissible limits of arsenic at pH 5.8–6.8. © 2012 American Institute of Chemical Engineers Environ Prog, 32: 1023–1029, 2013
- 10 September 2012
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 32 (4) , 1023-1029
A process for the selective removal of arsenic from contaminated water using acetate functionalized zinc oxide nanomaterials
This research article deals with the uptake of arsenic from contaminated water using acetate functionalized zinc oxide (ZnO) nanomaterials. The ZnO nanomaterials of various sizes (6–60 nm) have been synthesized following different wet chemical routes. The arsenic removal efficacy of acetate functionalized ZnO nanomaterials was carried out at different pH and time interval. It has been concluded from the study that ZnO nanomaterials (<60 nm) prepared by zinc acetate precursor effectively removes arsenic, while ZnO of same size prepared from zinc chloride, zinc nitrate, zinc sulphate precursor could not remove arsenic considerably. However, ZnO of same size synthesized using other than zinc acetate precursor and functionalized with acetate ions removes arsenic effectively. It is also proposed that acetate ions over the surface of ZnO adsorb arsenic by an oxo‐coordination mechanism and purifies water up to permissible limits of arsenic at pH 5.8–6.8. © 2012 American Institute of Chemical Engineers Environ Prog, 32: 1023–1029, 2013
- Open Access
- 16 August 2012
- Published by Springer Nature in SpringerPlus
- Vol. 1 (1) , 1-6
A rugged, precise and accurate new gravimetry method for the determination of gold: an alternative to fire assay method
A new, rugged, precise, accurate and fast primary method of measurement has been proposed for the determination of gold in various gold articles. Precise and accurate measurement of gold is the primary requirement for hall marking and to trade gold internationally, as billions of dollars of gold are trading world wide for the various applications. At present Fire Assay ASTM E 1335–08 is the only Standard Test Method for the determination of Gold, which is accepted internationally. But the method is time consuming, cumbersome and required expertise to perform the test. In the present investigation, a method has been developed gravimetry based on direct determination of gold after reducing gold in zero-valent state by hydroxylamine hydrochloride. Gravimetry is the most reliable technique and having highest metrological qualities in comparison to titremetry and instrumental method and the results of gravimetry are directly traceable to SI unit. The results of gravimetric method are accepted without reference to a standard of the same quantity. Several experiments were carried out with and without impurities and it has been concluded that gold can be determined accurately and precisely in presence of several impurities. Five replicates of approximate 0.2 g gold samples were analyzed following method proposed and percentage purity were found to be 99.993 ± 0.0056 with 95% confidence level (k = 2). The combined uncertainty in gold measurement has also been evaluated using potential sources of the method according to the EURACHEM/GUM guidelines.
- 16 August 2012
- Published by Springer Nature in SpringerPlus
- Vol. 1 (1) , 1-6
Open AccessA rugged, precise and accurate new gravimetry method for the determination of gold: an alternative to fire assay method
A new, rugged, precise, accurate and fast primary method of measurement has been proposed for the determination of gold in various gold articles. Precise and accurate measurement of gold is the primary requirement for hall marking and to trade gold internationally, as billions of dollars of gold are trading world wide for the various applications. At present Fire Assay ASTM E 1335–08 is the only Standard Test Method for the determination of Gold, which is accepted internationally. But the method is time consuming, cumbersome and required expertise to perform the test. In the present investigation, a method has been developed gravimetry based on direct determination of gold after reducing gold in zero-valent state by hydroxylamine hydrochloride. Gravimetry is the most reliable technique and having highest metrological qualities in comparison to titremetry and instrumental method and the results of gravimetry are directly traceable to SI unit. The results of gravimetric method are accepted without reference to a standard of the same quantity. Several experiments were carried out with and without impurities and it has been concluded that gold can be determined accurately and precisely in presence of several impurities. Five replicates of approximate 0.2 g gold samples were analyzed following method proposed and percentage purity were found to be 99.993 ± 0.0056 with 95% confidence level (k = 2). The combined uncertainty in gold measurement has also been evaluated using potential sources of the method according to the EURACHEM/GUM guidelines.
- Open Access
- 5 April 2011
- Published by Springer Nature in BMC Chemistry
- Vol. 5 (1) , 17
Quantifying uncertainty in the measurement of arsenic in suspended particulate matter by Atomic Absorption Spectrometry with hydride generator
Arsenic is the toxic element, which creates several problems in human being specially when inhaled through air. So the accurate and precise measurement of arsenic in suspended particulate matter (SPM) is of prime importance as it gives information about the level of toxicity in the environment, and preventive measures could be taken in the effective areas. Quality assurance is equally important in the measurement of arsenic in SPM samples before making any decision. The quality and reliability of the data of such volatile elements depends upon the measurement of uncertainty of each step involved from sampling to analysis. The analytical results quantifying uncertainty gives a measure of the confidence level of the concerned laboratory. So the main objective of this study was to determine arsenic content in SPM samples with uncertainty budget and to find out various potential sources of uncertainty, which affects the results. Keeping these facts, we have selected seven diverse sites of Delhi (National Capital of India) for quantification of arsenic content in SPM samples with uncertainty budget following sampling by HVS to analysis by Atomic Absorption Spectrometer-Hydride Generator (AAS-HG). In the measurement of arsenic in SPM samples so many steps are involved from sampling to final result and we have considered various potential sources of uncertainties. The calculation of uncertainty is based on ISO/IEC17025: 2005 document and EURACHEM guideline. It has been found that the final results mostly depend on the uncertainty in measurement mainly due to repeatability, final volume prepared for analysis, weighing balance and sampling by HVS. After the analysis of data of seven diverse sites of Delhi, it has been concluded that during the period from 31st Jan. 2008 to 7th Feb. 2008 the arsenic concentration varies from 1.44 ± 0.25 to 5.58 ± 0.55 ng/m3 with 95% confidence level (k = 2).
- 5 April 2011
- Published by Springer Nature in BMC Chemistry
- Vol. 5 (1) , 17
Open AccessQuantifying uncertainty in the measurement of arsenic in suspended particulate matter by Atomic Absorption Spectrometry with hydride generator
Arsenic is the toxic element, which creates several problems in human being specially when inhaled through air. So the accurate and precise measurement of arsenic in suspended particulate matter (SPM) is of prime importance as it gives information about the level of toxicity in the environment, and preventive measures could be taken in the effective areas. Quality assurance is equally important in the measurement of arsenic in SPM samples before making any decision. The quality and reliability of the data of such volatile elements depends upon the measurement of uncertainty of each step involved from sampling to analysis. The analytical results quantifying uncertainty gives a measure of the confidence level of the concerned laboratory. So the main objective of this study was to determine arsenic content in SPM samples with uncertainty budget and to find out various potential sources of uncertainty, which affects the results. Keeping these facts, we have selected seven diverse sites of Delhi (National Capital of India) for quantification of arsenic content in SPM samples with uncertainty budget following sampling by HVS to analysis by Atomic Absorption Spectrometer-Hydride Generator (AAS-HG). In the measurement of arsenic in SPM samples so many steps are involved from sampling to final result and we have considered various potential sources of uncertainties. The calculation of uncertainty is based on ISO/IEC17025: 2005 document and EURACHEM guideline. It has been found that the final results mostly depend on the uncertainty in measurement mainly due to repeatability, final volume prepared for analysis, weighing balance and sampling by HVS. After the analysis of data of seven diverse sites of Delhi, it has been concluded that during the period from 31st Jan. 2008 to 7th Feb. 2008 the arsenic concentration varies from 1.44 ± 0.25 to 5.58 ± 0.55 ng/m3 with 95% confidence level (k = 2).
- 1 June 2010
- Published by Springer Nature in MAPAN
- Vol. 25 (2) , 115-123
The quantitative estimation of silica in rice husk ash by titrimetric method: A case study for uncertainty calculation
- 1 June 2010
- Published by Springer Nature in MAPAN
- Vol. 25 (2) , 115-123
The quantitative estimation of silica in rice husk ash by titrimetric method: A case study for uncertainty calculation