LHLaura K. Holden

Laura K. Holden

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Laura K. Holden has a total of 28 co-authors. Here are the top co-authors by number of shared publications:

  • Jill B. Firszt

    Department of Otolaryngology Head and Neck Surgery, Washington University School of Medicine in St. Louis, St. Louis, Missouri

    4 shared publications
  • Timothy A. Holden

    Department of Otolaryngology Head and Neck Surgery, Washington University School of Medicine in St. Louis, St. Louis, Missouri

    4 shared publications
  • Margaret W. Skinner

    Department of Otolaryngology, Washington University School of Medicine, St. Louis, Missouri, USA

    3 shared publications
  • Brenda D. Gotter

    Department of Otolaryngology, Washington University School of Medicine, St. Louis, Missouri, USA

    2 shared publications
  • Charles C. Finley

    Department of Otolaryngology, Washington University School of Medicine, St. Louis, Missouri, USA

    2 shared publications
  • Christine Brenner

    Moog Center for Deaf Education, St. Louis, Missouri

    2 shared publications

Latest Publications

  • Factors Affecting Outcomes in Cochlear Implant Recipients Implanted With a Perimodiolar Electrode Array Located in Scala Tympani

    by Laura K. Holden, Jill B. Firszt, Ruth M. Reeder, Rosalie M. Uchanski, Noël Y. Dwyer, Timothy A. Holden

    Objective: To identify primary biographic and audiologic factors contributing to cochlear implant (CI) performance variability in quiet and noise by controlling electrode array type and electrode position within the cochlea. Background: Although CI outcomes have improved over time, considerable outcome variability still exists. Biographic, audiologic, and device-related factors have been shown to influence performance. Examining CI recipients with consistent array type and electrode position may allow focused investigation into outcome variability resulting from biographic and audiologic factors. Methods: Thirty-nine adults (40 ears) implanted for at least 6 months with a perimodiolar electrode array known (via computed tomography [CT] imaging) to be in scala tympani participated. Test materials, administered CI only, included monosyllabic words, sentences in quiet and noise, and spectral ripple discrimination. Results: In quiet, scores were high with mean word and sentence scores of 76 and 87%, respectively; however, sentence scores decreased by an average of 35 percentage points when noise was added. A principal components (PC) analysis of biographic and audiologic factors found three distinct factors, PC1 Age, PC2 Duration, and PC3 Pre-op Hearing. PC1 Age was the only factor that correlated, albeit modestly, with speech recognition in quiet and noise. Spectral ripple discrimination strongly correlated with speech measures. Conclusion: For these recipients with consistent electrode position, PC1 Age was related to speech recognition performance. Consistent electrode position may have contributed to high speech understanding in quiet. Inter-subject variability in noise may have been influenced by auditory/cognitive processing, known to decline with age, and mechanisms that underlie spectral resolution ability.


  • Postlingual adult performance in noise with HiRes 120 and ClearVoice Low, Medium, and High

    by Laura K. Holden, Christine Brenner, Ruth M. Reeder, Jill B. Firszt

    Objectives The study's objectives were to evaluate speech recognition in multiple listening conditions using several noise types with HiRes 120 and ClearVoice (Low, Medium, High) and to determine which ClearVoice program was most beneficial for everyday use. Methods Fifteen postlingual adults attended four sessions; speech recognition was assessed at sessions 1 and 3 with HiRes 120 and at sessions 2 and 4 with all ClearVoice programs. Test measures included sentences presented in restaurant noise (R-SPACETM), in speech-spectrum noise, in four- and eight-talker babble, and connected discourse presented in 12-talker babble. Participants completed a questionnaire comparing ClearVoice programs. Results Significant group differences in performance between HiRes 120 and ClearVoice were present only in the R-SPACETM; performance was better with ClearVoice High than HiRes 120. Among ClearVoice programs, no significant group differences were present for any measure. Individual results revealed most participants performed better in the R-SPACETM with ClearVoice than HiRes 120. For other measures, significant individual differences between HiRes 120 and ClearVoice were not prevalent. Individual results among ClearVoice programs differed and overall preferences varied. Questionnaire data indicated increased understanding with High and Medium in certain environments. Discussion R-SPACETM and questionnaire results indicated an advantage for ClearVoice High and Medium. Individual test and preference data showed mixed results between ClearVoice programs making global recommendations difficult; however, results suggest providing ClearVoice High and Medium and HiRes 120 as processor options for adults willing to change settings. For adults unwilling or unable to change settings, ClearVoice Medium is a practical choice for daily listening.


  • Top Cited Papers

    Factors Affecting Open-Set Word Recognition in Adults With Cochlear Implants

    by Laura K. Holden, Charles C. Finley, Jill B. Firszt, Timothy A. Holden, Christine Brenner, Lisa G. Potts, Brenda D. Gotter, Sallie S. Vanderhoof, Karen Mispagel, Gitry Heydebrand, et al.

    Objective: A great deal of variability exists in the speech-recognition abilities of postlingually deaf adult cochlear implant (CI) recipients. A number of previous studies have shown that duration of deafness is a primary factor affecting CI outcomes; however, there is little agreement regarding other factors that may affect performance. The objective of the present study was to determine the source of variability in CI outcomes by examining three main factors, biographic/audiologic information, electrode position within the cochlea, and cognitive abilities in a group of newly implanted CI recipients. Design: Participants were 114 postlingually deaf adults with either the Cochlear or Advanced Bionics CI systems. Biographic/audiologic information, aided sentence-recognition scores, a high resolution temporal bone CT scan and cognitive measures were obtained before implantation. Monosyllabic word recognition scores were obtained during numerous test intervals from 2 weeks to 2 years after initial activation of the CI. Electrode position within the cochlea was determined by three-dimensional reconstruction of pre- and postimplant CT scans. Participants’ word scores over 2 years were fit with a logistic curve to predict word score as a function of time and to highlight 4-word recognition metrics (CNC initial score, CNC final score, rise time to 90% of CNC final score, and CNC difference score). Results: Participants were divided into six outcome groups based on the percentile ranking of their CNC final score, that is, participants in the bottom 10% were in group 1; those in the top 10% were in group 6. Across outcome groups, significant relationships from low to high performance were identified. Biographic/audiologic factors of age at implantation, duration of hearing loss, duration of hearing aid use, and duration of severe-to-profound hearing loss were significantly and inversely related to performance as were frequency modulated tone, sound-field threshold levels obtained with the CI. That is, the higher-performing outcome groups were younger in age at the time of implantation, had shorter duration of severe-to-profound hearing loss, and had lower CI sound-field threshold levels. Significant inverse relationships across outcome groups were also observed for electrode position, specifically the percentage of electrodes in scala vestibuli as opposed to scala tympani and depth of insertion of the electrode array. In addition, positioning of electrode arrays closer to the modiolar wall was positively correlated with outcome. Cognitive ability was significantly and positively related to outcome; however, age at implantation and cognition were highly correlated. After controlling for age, cognition was no longer a factor affecting outcomes. Conclusion: There are a number of factors that limit CI outcomes. They can act singularly or collectively to restrict an individual’s performance and to varying degrees. The highest performing CI recipients are those with the least number of limiting factors. Knowledge of when and how these factors affect performance can favorably influence counseling, device fitting, and rehabilitation for individual patients and can contribute to improved device design and application.


  • Open Access

    Sequential Bilateral Cochlear Implantation in a Patient with Bilateral Ménière’s Disease

    by Laura K. Holden, J. Gail Neely, Brenda D. Gotter, Karen M. Mispagel, Jill B. Firszt

    This case study describes a 45-yr-old female with bilateral, profound sensorineural hearing loss due to Ménière’s disease. She received her first cochlear implant in the right ear in 2008 and the second cochlear implant in the left ear in 2010. The case study examines the enhancement to speech recognition, particularly in noise, provided by bilateral cochlear implants.Speech recognition tests were administered prior to obtaining the second implant and at a number of test intervals following activation of the second device. Speech recognition in quiet and noise as well as localization abilities were assessed in several conditions to determine bilateral benefit and performance differences between ears. The results of the speech recognition testing indicated a substantial improvement in the patient’s ability to understand speech in noise and her ability to localize sound when using bilateral cochlear implants compared to using a unilateral implant or an implant and a hearing aid. In addition, the patient reported considerable improvement in her ability to communicate in daily life when using bilateral implants versus a unilateral implant.This case suggests that cochlear implantation is a viable option for patients who have lost their hearing to Ménière’s disease even when a number of medical treatments and surgical interventions have been performed to control vertigo. In the case presented, bilateral cochlear implantation was necessary for this patient to communicate successfully at home and at work.


  • Optimizing the perception of soft speech and speech in noise with the Advanced Bionics cochlear implant system

    by Laura K. Holden, Ruth M. Reeder, Jill B. Firszt, Charles C. Finley

    Objective: This study aimed to provide guidelines to optimize perception of soft speech and speech in noise for Advanced Bionics cochlear implant (CI) users. Design: Three programs differing in T-levels were created for ten subjects. Using the T-level setting that provided the lowest FM-tone, sound-field threshold levels for each subject, three additional programs were created with input dynamic range (IDR) settings of 50, 65 and 80 dB. Study sample: Subjects were postlinguistically deaf adults implanted with either the Clarion CII or 90K CI devices. Results: Sound-field threshold levels were lowest with T-levels set higher than 10% of M-levels and with the two widest IDRs. Group data revealed significantly higher scores for CNC words presented at a soft level with an IDR of 80 dB and 65 dB compared to 50 dB. Although no significant group differences were seen between the three IDRs for sentences in noise, significant individual differences were present. Conclusions: Setting Ts higher than the manufacturer's recommendation of 10% of M-levels and providing IDR options can improve overall speech perception; however, for some users, higher Ts and wider IDRs may not be appropriate. Based on the results of the study, clinical programming recommendations are provided. Sumario Objetivo: Este estudio buscó proporcionar pautas para optimizar la percepción del lenguaje suave y del lenguaje en ruido para usuarios del implante coclear (IC) de Advanced Bionics. Diseño: Se crearon tres programas para diez pacientes, que eran diferentes en sus niveles T. Al usar el control de nivel T que proporcionaba el tono FM más bajo, con niveles de umbral en campo libre para cada sujeto, se crearon tres programas adicionales con controles de ingreso del rango dinámico IRD de 50, 65 y 80 dB. Muestra de Estudio: Los sujetos fueron sordos adultos postlingüísticos implantados con los modelos Clarion CII o 90K CI. Resultados: Los niveles de umbral en campo libre fueron más bajos con los niveles T colocados 10% más alto que los niveles M y con los dos IDR más anchos. Los datos del grupo revelaron puntuaciones significativamente mayores con palabras CNC presentadas en un nivel suave con un IDR de 80 dB y 65 dB comparados con 50 dB. No obstante que no se encontraron diferencias significativas en los grupos entre los tres IDR para oraciones en ruido, si se presentaron diferencias significativas individuales. Conclusiones: La colocación de los niveles T más altos en 10% que la recomendación del fabricante, sobre los niveles M y el proporcionar opciones de IDR, en general pueden mejorar la percepción del lenguaje; no obstante, niveles mayores de T y IDR más anchas, pueden no ser apropiados para algunos usuarios. Con base en los resultados de este estudio, se proporcionan recomendaciones clínicas para la programación.


  • Effect of Increased IIDR in the Nucleus Freedom Cochlear Implant System

    by Laura K. Holden, Margaret W. Skinner, Marios S. Fourakis, Timothy A. Holden

    The objective of this study was to evaluate the effect of the increased instantaneous input dynamic range (IIDR) in the Nucleus Freedom cochlear implant (CI) system on recipients' ability to perceive soft speech and speech in noise. Ten adult Freedom CI recipients participated. Two maps differing in IIDR were placed on each subject's processor at initial activation. The IIDR was set to 30 dB for one map and 40 dB for the other. Subjects used both maps for at least one month prior to speech perception testing. Results revealed significantly higher scores for words (50 dB SPL), for sentences in background babble (65 dB SPL), and significantly lower sound field threshold levels with the 40 compared to the 30 dB IIDR map. Ceiling effects may have contributed to non-significant findings for sentences in quiet (50 dB SPL). The Freedom's increased IIDR allows better perception of soft speech and speech in noise. El objetivo de este estudio fue evaluar el efecto del rango dinámico aumentado instantáneo de ingreso (IIDR) en el sistema de implante coclear (IC) Nucleus Freedom, sobre la capacidad de sujetos implantados para percibir lenguaje a bajo volumen y lenguaje en ruido. Diez sujetos implantados con el IC Freedom participaron. En la activación inicial, dos mapas con una diferencia en cuanto al IIDR se colocaron en el procesador de cada sujeto. El IIDR fue ajustado a 30 dB para un mapa y a 40 dB para el otro. Los sujetos utilizaron ambos mapas por al menos un mes, antes de una evaluación de percepción del lenguaje. Los resultados revelaron puntajes significativamente más altos para palabras (50 dB SPL), para frases en balbuceo de fondo (65 dB SPL), y niveles umbrales en campo libre significativamente más bajos con el mapa de IIDR de 40 comparado con el de 30. Efectos tope pueden haber contribuido a los hallazgos no significativos para frases en silencio (50 dB SPL). El IIDR aumentado para Freedom permite mejor percepción para el lenguaje a bajo volumen y el lenguaje en medio de ruido.


  • Speech Recognition With the Advanced Combination Encoder and Transient Emphasis Spectral Maxima Strategies in Nucleus 24 Recipients

    by Laura K. Holden, Andrew E. Vandali, Margaret W. Skinner, Marios S. Fourakis, Timothy A. Holden

    One of the difficulties faced by cochlear implant (CI) recipients is perception of low-intensity speech cues. A. E. Vandali (2001) has developed the transient emphasis spectral maxima (TESM) strategy to amplify short-duration, low-level sounds. The aim of the present study was to determine whether speech scores would be significantly higher with TESM than with the advanced combination encoder (ACE) strategy fitted using procedures that optimize perception of soft speech and other sounds. Eight adult recipients of the Nucleus 24 CI system participated in this study. No significant differences in scores were seen between ACE and TESM for consonant-vowel nucleus-consonant (CNC) words presented at 55 and 65 dB SPL, for sentences in noise presented at 65 dB SPL at 2 different signal-to-noise ratios, or for closed-set vowels and consonants presented at 60 dB SPL. However, perception of stop consonants within CNC words presented at the lower level (55 dB SPL) was significantly higher with TESM than ACE. In addition, percentage of information transmitted for words at 55 dB SPL was significantly higher with TESM than with ACE for manner and voicing features for consonants in the initial word position. Analysis of closed-set consonants presented at 60 dB SPL revealed percentage of information transmitted for manner was significantly higher with TESM than with ACE. These improvements with TESM were small compared with those reported by Vandali for recipients of the Nucleus 22 CI system. It appears that mapping techniques used to program speech processors and improved processing capabilities of the Nucleus 24 system contributed to soft sounds being understood almost as well with ACE as with TESM. However, half of the participants preferred TESM to ACE for use in everyday life, and all but 1 used TESM in specific listening situations. Clinically, TESM may be useful to ensure the audibility of low-intensity, short-duration acoustic cues that are important for understanding speech, for recipients who are difficult to map, or if insufficient time precludes the use of mapping techniques to increase audibility of soft sound.


  • Is There a Relation between Speech Recognition and the Position of Cochlear Implant Electrodes in the Inner Ear?

    by Margaret W. Skinner, Darlene R. Ketten, Laura K. Holden, Bruce R. Whiting, Lawrence T. Cohen, Gary W. Harding, Kyongtae Bae, Peter G. Smith, George A. Gates, J. Gail Neely, et al.

    The anatomical position of the Nucleus-22 electrode array in the cochleae of 33 postlinguistically deaf adults has been estimated from spiral CT images.[ 1 ] [ 2 ] For 13 of these adults, the position of individual electrodes also has been derived from 2D radiographs[ 3 ] [ 4 ] with projection of the CT-derived array onto the radiographs.[ 5 ] Array insertion depth of the most apical electrode expressed as percentage of total cochlear canal length was significantly correlated with mean NU-6 word score for the 26 patients who had used the spectral peak (SPEAK) strategy for a year at the time of testing (r=0.452; p=0.020). This correlation is modest because the site of electrical stimulation in the cochlea is only one factor contributing to word recognition. It is well known that age at implantation and duration of deafness have a negative effect and number of years implant use has a positive effect on word recognition in postlinguistically deaf adults.[ 6 ] [ 7 ] Analyses of patients' scores suggest that etiologies that adversely affect the number of remaining auditory neurons (e.g., bacterial labyrinthitis, syphilis) or abnormal electrical current paths within the cochlea (e.g., otosclerosis) are associated with scores below the regression line. A number of patients with less than full insertion (i.e., between 52 and 64% of the total cochlear length) had excellent verbal skills and word scores substantially higher than the regression line. Because there was less than full insertion, the frequency bands of incoming sound assigned to the active electrodes were substantially lower than the estimated characteristic frequency of nearby neurons for these patients. For one patient, the frequency band assigned to the most apical electrode, 22 (paired with electrode 20), was 120 to 280 Hz in the speech processor program; the characteristic frequency estimated at this most apical electrode position was 1485 Hz. It is hypothesized that these patients' high scores were associated with their above average verbal skills, a year or more of implant experience, above average survival of auditory neurons, and sufficient central auditory nervous system plasticity to adapt to the shift in frequency of incoming sound to a higher pitch percept from stimulation with the implant than would normally be perceived acoustically. Documented improvement in these patients' word scores obtained at 3 months, 6 months, and yearly intervals thereafter with the multipeak (MPEAK) and SPEAK strategies lends support for the hypothesized neural plasticity.