TMThitima Maturos

Thitima Maturos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Thitima Maturos has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • Tanom Lomas

    Nanoelectronics and MEMS laboratory, National Electronics and Computer Technology Center (NECTEC), 112 Paholyothin Rd., Klong 1, Klong Luang, Pathumthani, Thailand

    2 shared publications
  • Adisorn Tuantranont

    National Electronics and Computer Technology Center (NECTEC)

    1 shared publication
  • Adisorn Tuantranont

    Nanoelectronics and MEMS Laboratory, National Electronics and Computer Technology Centre, Pathum Thani, 12120, Thailand

    1 shared publication
  • Anurat Wisitsoraat

    Nanoelectronics and MEMS laboratory, National Electronics and Computer Technology Center (NECTEC), 112 Paholyothin Rd., Klong 1, Klong Luang, Pathumthani, Thailand

    1 shared publication
  • Assawapong Sappat

    Nanoelectronics and MEMS Laboratory, National Electronics and Computer Technology Centre, Pathum Thani, 12120, Thailand

    1 shared publication
  • Chayapat Wongsombat

    National Center for Genetic Engineering and Biotechnology (BIOTEC), 113 Paholyothin Rd., Klong 1, Klong Luang, Pathumthani, Thailand

    1 shared publication

Latest Publications

  • DNA hybridization enhancement using piezoelectric microagitation through a liquid coupling medium

    by Kiattimant Rodaree, Thitima Maturos, Sastra Chaotheing, Tawee Pogfay, Nattida Suwanakitti, Chayapat Wongsombat, Kata Jaruwongrungsee, Anurat Wisitsoraat, Sumalee Kamchonwongpaisan, Tanom Lomas, et al.

    In conventional DNA microarray hybridization, delivery of target cDNAs to surface-bounded probes depends solely on diffusion, which is notoriously slow, and thus typically requires 6–20 h to complete. In this study, piezoelectric microagitation through a liquid coupling medium is employed to enhance DNA hybridization efficiency and the results are compared with the standard static hybridization method. DNA hybridization was performed in a sealed aluminium chamber containing DNA microarray glass chip, coupling medium and piezoelectric transducers. 3 × SSC (Saline Sodium Citrate) was used as a coupling medium to prevent overheating of the piezoelectric transducers and to effectively transmit ultrasonic wave to the glass chip. Flow visualization using fluidic dye and velocimetry (PTV) technique was applied to observe fluid transport in the hybridization chamber. It was revealed that the dye solution was homogeneously distributed within 10 min under dynamic agitation while it took over 1 h to reach the same level of homogeneity in static condition. Plasmodium falciparumDNA microarrays and total RNA extracted from parasite cells were used as a model for DNA microarray experiments. It was found that the required hybridization time may be substantially reduced from 16 h to 4 h by the use of dynamic hybridization scheme. With the same hybridization time of 16 h, dynamic hybridization resulted in higher fluorescent signals of ∼33% and ∼24% compared to static hybridization in Cy3 and Cy5 channels, respectively. Additionally, good/effective spots, some of which were not formed by static method, were enhanced and distributed more uniformly over the microarray. Therefore, the developed dynamic hybridization with integrated piezoelectric microagitation platform is highly promising for DNA analysis in molecular biology and medical applications.


  • Open Access

    On-Chip Immunoassay for Determination of Urinary Albumin

    by Wanida Laiwattanapaisal, Temsiri Songjaroen, Thitima Maturos, Tanom Lomas, Assawapong Sappat, Adisorn Tuantranont

    An immunoassay performed on a portable microfluidic device was evaluated for the determination of urinary albumin. An increase in absorbance at 500 nm resulting from immunoagglutination was monitored directly on the poly(dimethylsiloxane) (PDMS) microchip using a portable miniature fibre-optic spectrometer. A calibration curve was linear up to 10 mg L–1 (r2 = 0.993), with a detection limit of 0.81 mg L–1 (S/N = 3). The proposed system showed good precision, with relative standard deviations (RSDs) of 5.1%, when evaluated with 10 mg L–1 albumin (n = 10). Determination of urinary albumin with the proposed system gave results highly similar to those determined by the conventional spectrophotometric method using immunoturbidimetric detection (r2 = 0.995; n = 15).