Chung-Chi Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chung-Chi Lee has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Tsi-Chian Chao
Chang Gung Univ. (Taiwan)
10 shared publications - Chuan-Jong Tung
Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Kwei-Shan, Tao-Yuan 333, Taiwan
6 shared publications Pei-Chieh Yu
3 shared publications- Cher Ming Tan
Chang Gung University
2 shared publications Ching-Jung Wu
2 shared publications- Shu-Ju Tu
Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan
2 shared publications
Latest Publications
- Open Access
- 26 January 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (3) , 1113
Lineal Energy of Proton in Silicon by a Microdosimetry Simulation
Single event upset, or Single Event Effect (SEE) is increasingly important as semiconductor devices are entering into nano-meter scale. The Linear Energy Transfer (LET) concept is commonly used to estimate the rate of SEE. The SEE, however, should be related to energy deposition of each stochastic event, but not LET which is a non-stochastic quantity. Instead, microdosimetry, which uses a lineal calculation of energy lost per step for each specific track, should be used to replace LET to predict microelectronic failure from SEEs. Monte Carlo simulation is used for the demonstration, and there are several parameters needed to optimise for SEE simulation, such as the target size, physical models and scoring techniques. We also show the thickness of the sensitive volume, which also correspond to the size of a device, will change the spectra of lineal energy. With a more comprehensive Monte Carlo simulation performed in this work, we also show and explain the differences in our results and the reported results such as those from Hiemstra et al. which are commonly used in semiconductor industry for the prediction of SEE in devices.
- 26 January 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (3) , 1113
Open AccessLineal Energy of Proton in Silicon by a Microdosimetry Simulation
Single event upset, or Single Event Effect (SEE) is increasingly important as semiconductor devices are entering into nano-meter scale. The Linear Energy Transfer (LET) concept is commonly used to estimate the rate of SEE. The SEE, however, should be related to energy deposition of each stochastic event, but not LET which is a non-stochastic quantity. Instead, microdosimetry, which uses a lineal calculation of energy lost per step for each specific track, should be used to replace LET to predict microelectronic failure from SEEs. Monte Carlo simulation is used for the demonstration, and there are several parameters needed to optimise for SEE simulation, such as the target size, physical models and scoring techniques. We also show the thickness of the sensitive volume, which also correspond to the size of a device, will change the spectra of lineal energy. With a more comprehensive Monte Carlo simulation performed in this work, we also show and explain the differences in our results and the reported results such as those from Hiemstra et al. which are commonly used in semiconductor industry for the prediction of SEE in devices.
- Open Access
- 6 May 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (9) , 3234
Investigate the Equivalence of Neutrons and Protons in Single Event Effects Testing: A Geant4 Study
Neutron radiation on advanced integrated circuits (ICs) is becoming important for their reliable operation. However, a neutron test on ICs is expensive and time-consuming. In this work, we employ Monte Carlo simulation to examine if a proton test can replace or even accelerate the neutron test, and we found that 200 MeV protons are the closest to resembling neutron radiation with five main differences. This 200 MeV concur with the suggestion from National Aeronautics and Space Administration (NASA, Washington, DC, USA). However, the impacts of the five differences on single event effects (SEEs) require future work for examination.
- 6 May 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (9) , 3234
Open AccessInvestigate the Equivalence of Neutrons and Protons in Single Event Effects Testing: A Geant4 Study
Neutron radiation on advanced integrated circuits (ICs) is becoming important for their reliable operation. However, a neutron test on ICs is expensive and time-consuming. In this work, we employ Monte Carlo simulation to examine if a proton test can replace or even accelerate the neutron test, and we found that 200 MeV protons are the closest to resembling neutron radiation with five main differences. This 200 MeV concur with the suggestion from National Aeronautics and Space Administration (NASA, Washington, DC, USA). However, the impacts of the five differences on single event effects (SEEs) require future work for examination.
- 1 November 2017
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 140, 290-294
Ambient neutron dose equivalent during proton therapy using wobbling scanning system: Measurements and calculations
- 1 November 2017
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 140, 290-294
Ambient neutron dose equivalent during proton therapy using wobbling scanning system: Measurements and calculations
- 1 August 2017
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 137, 121-124
An MCNPX2.7.0 study of Bragg peak degradation owing to density heterogeneity patterns for a CGMH therapeutic proton beam
- 1 August 2017
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 137, 121-124
An MCNPX2.7.0 study of Bragg peak degradation owing to density heterogeneity patterns for a CGMH therapeutic proton beam
- Open Access
- 1 January 2013
- Published by Elsevier in Biomedical Journal
- Vol. 36 (2) , 71
Pre-radiotherapy PSA Level as a Predictor for Biochemical Control in Prostate Cancer Patients Receiving Radiotherapy after Radical Prostatectomy
- 1 January 2013
- Published by Elsevier in Biomedical Journal
- Vol. 36 (2) , 71
Open AccessPre-radiotherapy PSA Level as a Predictor for Biochemical Control in Prostate Cancer Patients Receiving Radiotherapy after Radical Prostatectomy
- 1 December 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (12) , 2003-2005
Monte Carlo simulation of small field electron beams for small animal irradiation
- 1 December 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (12) , 2003-2005
Monte Carlo simulation of small field electron beams for small animal irradiation
- 1 December 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (12) , 1956-1959
In vivo dosimetry with asymmetry and heterogeneity correction
- 1 December 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (12) , 1956-1959
In vivo dosimetry with asymmetry and heterogeneity correction
- 1 December 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (12) , 2028-2030
Dose assessment for brachytherapy with Henschke applicator
- 1 December 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (12) , 2028-2030
Dose assessment for brachytherapy with Henschke applicator
- 1 December 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (12) , 1932-1935
Development of a novel optical CT employing a laser to create a collimated line-source with a flat-top intensity distribution
- 1 December 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (12) , 1932-1935
Development of a novel optical CT employing a laser to create a collimated line-source with a flat-top intensity distribution
- 1 December 2010
- Published by Elsevier in Medical Dosimetry
- Vol. 35 (4) , 304-311
Midline Dose Verification with Diode In Vivo Dosimetry for External Photon Therapy of Head and Neck and Pelvis Cancers During Initial Large-Field Treatments
- 1 December 2010
- Published by Elsevier in Medical Dosimetry
- Vol. 35 (4) , 304-311
Midline Dose Verification with Diode In Vivo Dosimetry for External Photon Therapy of Head and Neck and Pelvis Cancers During Initial Large-Field Treatments