Gianfranco Gualdrini
Research Subjects
Gianfranco Gualdrini has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
F. Monteventi
ENEA-IRP Radiation Protection Institute , Via dei Colli 16, 40136 Bologna (BO) , Italy
3 shared publicationsP. Ferrari
ENEA, Agenzia Nazionale per le Nuove tecnologie, l'Energia e lo Sviluppo economico sostenibile , 16, via dei colli, 40136 Bologna , Italy
3 shared publications- B. Morelli
ENEA Radiation Protection Institute , Via dei Colli 16 I-40136, Bologna , Italy
2 shared publications E. Carinou
Greek Atomic Energy Commission
2 shared publicationsE. Fantuzzi
ENEA, Agenzia Nazionale per le Nuove tecnologie, l'Energia e lo Sviluppo economico sostenibile , 16, via dei colli, 40136 Bologna , Italy
2 shared publications- E. Fantuzzi
ENEA Radiation Protection Institute , Via dei Colli 16 I-40136, Bologna , Italy
2 shared publications
Latest Publications
- 1 October 2013
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 161 (1) , 17-22
Hp(3)/ conversion coefficients for neutrons: discussion on the basis of the new ICRP recommended limit for the eye lens
The new recommendation issued by the International Commission on Radiological Protection (ICRP) introducing a 20-mSv annual dose limit for the eye lens stimulated an interesting debate among the radiation protection community. In the present work the problem of estimating Hp(3) for neutron realistic workplace spectra is treated, employing the recently published Hp(3)/Φ conversion coefficients with the aim of establishing a workplace-dependent relationship between Hp(10) and Hp(3). The results demonstrate that, whilst the two quantities can differ by less than 10 %, in general, Hp(10) cannot be considered a conservative estimate of Hp(3).
- 1 October 2013
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 161 (1) , 17-22
Hp(3)/ conversion coefficients for neutrons: discussion on the basis of the new ICRP recommended limit for the eye lens
The new recommendation issued by the International Commission on Radiological Protection (ICRP) introducing a 20-mSv annual dose limit for the eye lens stimulated an interesting debate among the radiation protection community. In the present work the problem of estimating Hp(3) for neutron realistic workplace spectra is treated, employing the recently published Hp(3)/Φ conversion coefficients with the aim of establishing a workplace-dependent relationship between Hp(10) and Hp(3). The results demonstrate that, whilst the two quantities can differ by less than 10 %, in general, Hp(10) cannot be considered a conservative estimate of Hp(3).
- Open Access
- 24 October 2012
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 154 (4) , 517-521
Air kerma to HP(3) conversion coefficients for photons from 10 keV to 10 MeV, calculated in a cylindrical phantom
In the framework of the ORAMED project (Optimization of RAdiation protection for MEDical staff), funded by the European Union Seventh Framework Programme, different studies were aimed at improving the quality of radiation protection in interventional radiology and nuclear medicine. The main results of the project were presented during a final workshop held in Barcelona in January 2011, the proceedings of which are available in the open literature. One of the ORAMED tasks was focused on the problem of eye-lens photon exposure of the medical staff, a topic that gained more importance especially after the ICRP decision to lower the limiting equivalent dose to 20 mSv per year. The present technical note has the scope, besides briefly summarising the physical reasons of the proposal and the practical implications, to provide, in tabular form, a set of air kerma to Hp(3) conversion coefficients based on the adoption of a theoretical cylindrical model that is well suited for reproduction of the mass and the shape of a human head.
- 24 October 2012
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 154 (4) , 517-521
Open AccessAir kerma to HP(3) conversion coefficients for photons from 10 keV to 10 MeV, calculated in a cylindrical phantom
In the framework of the ORAMED project (Optimization of RAdiation protection for MEDical staff), funded by the European Union Seventh Framework Programme, different studies were aimed at improving the quality of radiation protection in interventional radiology and nuclear medicine. The main results of the project were presented during a final workshop held in Barcelona in January 2011, the proceedings of which are available in the open literature. One of the ORAMED tasks was focused on the problem of eye-lens photon exposure of the medical staff, a topic that gained more importance especially after the ICRP decision to lower the limiting equivalent dose to 20 mSv per year. The present technical note has the scope, besides briefly summarising the physical reasons of the proposal and the practical implications, to provide, in tabular form, a set of air kerma to Hp(3) conversion coefficients based on the adoption of a theoretical cylindrical model that is well suited for reproduction of the mass and the shape of a human head.
- 30 November 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (11) , 1235-1238
Proposals for the type tests criteria and calibration conditions of passive eye lens dosemeters to be used in interventional cardiology and radiology workplaces
- 30 November 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (11) , 1235-1238
Proposals for the type tests criteria and calibration conditions of passive eye lens dosemeters to be used in interventional cardiology and radiology workplaces
- 1 July 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 146 (4) , 425-433
Monte Carlo variance reduction techniques: an overview with some practical examples
Since the first developments of Monte Carlo radiation transport codes, the importance of solving deep penetration problems in the phase space was pointed out. Whilst natural Monte Carlo radiation transport models are rather easy and straightforward to be implemented, apart from geometry extreme complexities that could limit the modelling capabilities of the user, the possibility to obtain results with high precision and reasonable CPU time, when the scored events contributing to the response of interest are characterised by a low probability of occurrence, can be guaranteed only through biased games for which the user needs a robust expertise. The present paper wanted to present in a concise way the main aspects of the variance reduction techniques and some practical application to help the users in becoming more familiar with such a necessary tool.
- 1 July 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 146 (4) , 425-433
Monte Carlo variance reduction techniques: an overview with some practical examples
Since the first developments of Monte Carlo radiation transport codes, the importance of solving deep penetration problems in the phase space was pointed out. Whilst natural Monte Carlo radiation transport models are rather easy and straightforward to be implemented, apart from geometry extreme complexities that could limit the modelling capabilities of the user, the possibility to obtain results with high precision and reasonable CPU time, when the scored events contributing to the response of interest are characterised by a low probability of occurrence, can be guaranteed only through biased games for which the user needs a robust expertise. The present paper wanted to present in a concise way the main aspects of the variance reduction techniques and some practical application to help the users in becoming more familiar with such a necessary tool.
- Open Access
- 20 February 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 144 (1-4) , 473-477
Eye lens dosimetry: task 2 within the ORAMED project
The ORAMED (Optimization of RAdiation protection for MEDical staff) project is funded by EU-EURATOM within the 7° Framework Programme. Task 2 of the project is devoted to study the dose to the eye lens. The study was subdivided into various topics, starting from a critical revision of the operational quantity Hp(3), with the corresponding proposal of a cylindrical phantom simulating as best as possible the head in which the eyes are located, the production of a complete set of air kerma to dose equivalent conversion coefficients for photons from 10 keV to 10 MeV, and finally, the optimisation of the design of a personal dosemeter well suited to respond in terms of Hp(3). The paper presents some preliminary results.
- 20 February 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 144 (1-4) , 473-477
Open AccessEye lens dosimetry: task 2 within the ORAMED project
The ORAMED (Optimization of RAdiation protection for MEDical staff) project is funded by EU-EURATOM within the 7° Framework Programme. Task 2 of the project is devoted to study the dose to the eye lens. The study was subdivided into various topics, starting from a critical revision of the operational quantity Hp(3), with the corresponding proposal of a cylindrical phantom simulating as best as possible the head in which the eyes are located, the production of a complete set of air kerma to dose equivalent conversion coefficients for photons from 10 keV to 10 MeV, and finally, the optimisation of the design of a personal dosemeter well suited to respond in terms of Hp(3). The paper presents some preliminary results.
- 10 January 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 144 (1-4) , 187-191
ENEA extremity dosemeter based on LiF(Mg,Cu,P) to evaluate Hp(3, )
Recent epidemiological studies suggest a rather low-dose threshold (Hp(d), in §(136), reads that ‘… a depth d=3 mm has been proposed for the rare case of monitoring the dose to the lens of the eye. In practice, however, Hp(3) has rarely been monitored and Hp(0.07) can be used for the same monitoring purpose… ’. As recommended on the EU ‘Technical recommendations for monitoring individuals occupationally exposed to external radiation’, a test on the ENEA TL extremity dosemeter is herein reported. The results within the actual EU founded Optimization of RAdiation protection for MEDical staff (ORAMED) Project, whose WP2 is aimed at the quantity Hp(3) and eye lens dosimetry in practice, are taken into account. The paper summarises the main aspects of the study carried out at ENEA-Radiation Protection Institute (Bologna, Italy) to provide practical solutions (in the use and the design) to evaluate the response of the ENEA TL extremity dosemeter in terms of Hp(3).
- 10 January 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 144 (1-4) , 187-191
ENEA extremity dosemeter based on LiF(Mg,Cu,P) to evaluate Hp(3, )
Recent epidemiological studies suggest a rather low-dose threshold (Hp(d), in §(136), reads that ‘… a depth d=3 mm has been proposed for the rare case of monitoring the dose to the lens of the eye. In practice, however, Hp(3) has rarely been monitored and Hp(0.07) can be used for the same monitoring purpose… ’. As recommended on the EU ‘Technical recommendations for monitoring individuals occupationally exposed to external radiation’, a test on the ENEA TL extremity dosemeter is herein reported. The results within the actual EU founded Optimization of RAdiation protection for MEDical staff (ORAMED) Project, whose WP2 is aimed at the quantity Hp(3) and eye lens dosimetry in practice, are taken into account. The paper summarises the main aspects of the study carried out at ENEA-Radiation Protection Institute (Bologna, Italy) to provide practical solutions (in the use and the design) to evaluate the response of the ENEA TL extremity dosemeter in terms of Hp(3).
- 10 May 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 141 (1) , 82-85
Evaluation of the dose to the patient and medical staff in interventional cardiology employing computational models
Interventional radiology, among guided X-rays procedures, is a methodology characterised by high level of doses, both for the patient and for the medical staff. The aim of the present study is to estimate the dose associated with coronary angiography procedures by means of numerical models (simplified and anthropomorphic) and MCNPX Monte Carlo code. Numerical estimates were supported by measurement performed with a dose area product meter that is commonly employed in such kind of studies. In the present work the main considerations and the preliminary results are presented.
- 10 May 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 141 (1) , 82-85
Evaluation of the dose to the patient and medical staff in interventional cardiology employing computational models
Interventional radiology, among guided X-rays procedures, is a methodology characterised by high level of doses, both for the patient and for the medical staff. The aim of the present study is to estimate the dose associated with coronary angiography procedures by means of numerical models (simplified and anthropomorphic) and MCNPX Monte Carlo code. Numerical estimates were supported by measurement performed with a dose area product meter that is commonly employed in such kind of studies. In the present work the main considerations and the preliminary results are presented.
- 12 April 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 140 (4) , 383-390
A review of voxel model development and radiation protection applications at ENEA
The need of organ absorbed dose evaluation for radiation protection purposes stimulated, since the late 1960s, the development of anthropoid models to be used with radiation transport codes. Very significant improvements were introduced during the years, passing from stylised analytical human models to realistic voxel models based on computed tomography scans or MRI scans, and finally to advanced surface-geometry models. Besides illustrating the main contributions in this field from various international laboratories, this paper illustrates some applications of voxel models to internal (including in vivo monitoring) and external dosimetry for radiation protection.
- 12 April 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 140 (4) , 383-390
A review of voxel model development and radiation protection applications at ENEA
The need of organ absorbed dose evaluation for radiation protection purposes stimulated, since the late 1960s, the development of anthropoid models to be used with radiation transport codes. Very significant improvements were introduced during the years, passing from stylised analytical human models to realistic voxel models based on computed tomography scans or MRI scans, and finally to advanced surface-geometry models. Besides illustrating the main contributions in this field from various international laboratories, this paper illustrates some applications of voxel models to internal (including in vivo monitoring) and external dosimetry for radiation protection.
- 1 January 2009
- Published by Springer Nature in IFMBE Proceedings
- p. 470-473
The ORAMED Project: Optimisation of Radiation Protection for Medical Staff
- 1 January 2009
- Published by Springer Nature in IFMBE Proceedings
- p. 470-473
The ORAMED Project: Optimisation of Radiation Protection for Medical Staff
- 7 June 2007
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 127 (1-4) , 209-213
MCNPX internal dosimetry studies based on the NORMAN-05 voxel model
Anthropomorphic computational models coupled with radiation transport codes are valuable tools in radiation protection dosimetry. In particular, they are very reliable for the estimate of the energy absorbed by different organs due to an incorporated radionuclide. MIRD-based stylised analytical models are widely accepted as standards but the recent generation of voxel phantoms, developed on real anatomical data derived from tomographic images, can represent a valid alternative for radiation protection and dosimetry purposes. Specific absorbed fraction evaluation and patient-specific dose estimate in nuclear medicine and radiotherapy could be considered as the optimal area for their implementation and use. On the other hand, the accuracy of organ and body structure representation guarantees an improved dose evaluation system also for radiation protection purposes in the workplace in case of accidental internal contamination. In the present work the voxel model NORMAN-05, a modified version of NORMAN (HPA, UK) model, has been employed with the Monte Carlo code MCNPX. Some preliminary investigations were carried out to evaluate the absorbed fractions for a series of source–target organ couples in case of gamma emitters and the organ absorbed doses in case of 90Sr incorporation. The paper summarises the main preliminary outcomes of such studies.
- 7 June 2007
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 127 (1-4) , 209-213
MCNPX internal dosimetry studies based on the NORMAN-05 voxel model
Anthropomorphic computational models coupled with radiation transport codes are valuable tools in radiation protection dosimetry. In particular, they are very reliable for the estimate of the energy absorbed by different organs due to an incorporated radionuclide. MIRD-based stylised analytical models are widely accepted as standards but the recent generation of voxel phantoms, developed on real anatomical data derived from tomographic images, can represent a valid alternative for radiation protection and dosimetry purposes. Specific absorbed fraction evaluation and patient-specific dose estimate in nuclear medicine and radiotherapy could be considered as the optimal area for their implementation and use. On the other hand, the accuracy of organ and body structure representation guarantees an improved dose evaluation system also for radiation protection purposes in the workplace in case of accidental internal contamination. In the present work the voxel model NORMAN-05, a modified version of NORMAN (HPA, UK) model, has been employed with the Monte Carlo code MCNPX. Some preliminary investigations were carried out to evaluate the absorbed fractions for a series of source–target organ couples in case of gamma emitters and the organ absorbed doses in case of 90Sr incorporation. The paper summarises the main preliminary outcomes of such studies.