EAE. S. M. Ali

E. S. M. Ali

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


E. S. M. Ali has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Sci-Fri PM: Dosimetry-05: Megavoltage electron backscatter: EGSnrc results versus 21 experiments

    by E. S. M. Ali, W. Buchenberg, D. W. O. Rogers

  • Unfolding linac photon spectra and incident electron energies from experimental transmission data, with direct independent validation

    by E. S. M. Ali, M. R. McEwen, D. W. O. Rogers

    Purpose: In a recent computational study, an improved physics‐based approach was proposed for unfolding linac photon spectra and incident electron energies from transmission data. In this approach, energy differentiation is improved by simultaneously using transmission data for multiple attenuators and detectors, and the unfolding robustness is improved by using a four‐parameter functional form to describe the photon spectrum. The purpose of the current study is to validate this approach experimentally, and to demonstrate its application on a typical clinical linac.Methods: The validation makes use of the recent transmission measurements performed on the Vickers research linac of National Research Council Canada. For this linac, the photon spectra were previously measured using a NaI detector, and the incident electron parameters are independently known. The transmission data are for eight beams in the range 10–30 MV using thick Be, Al and Pb bremsstrahlung targets. To demonstrate the approach on a typical clinical linac, new measurements are performed on an ElektaPrecise linac for 6, 10 and 25 MV beams. The different experimental setups are modeled using EGSnrc, with the newly added photonuclear attenuation included.Results: For the validation on the research linac, the 95% confidence bounds of the unfolded spectra fall within the noise of the NaI data. The unfolded spectra agree with theEGSnrc spectra (calculated using independently known electron parameters) with RMS energy fluence deviations of 4.5%. The accuracy of unfolding the incident electron energy is shown to be ∼3%. A transmission cutoff of only 10% is suitable for accurate unfolding, provided that the other components of the proposed approach are implemented. For the demonstration on a clinical linac, the unfolded incident electron energies and their 68% confidence bounds for the 6, 10 and 25 MV beams are 6.1 ± 0.1, 9.3 ± 0.1, and 19.3 ± 0.2 MeV, respectively. The unfolded spectra for the clinical linac agree with the EGSnrc spectra (calculated using the unfolded electron energies) with RMS energy fluence deviations of 3.7%. The corresponding measured and EGSnrc‐calculated transmission data agree within 1.5%, where the typical transmission measurement uncertainty on the clinical linac is 0.4% (not including the uncertainties on the incident electron parameters).Conclusions: The approach proposed in an earlier study for unfolding photon spectra and incident electron energies from transmission data is accurate and practical for clinical use.


  • Detailed high-accuracy megavoltage transmission measurements: A sensitive experimental benchmark of EGSnrc

    by E. S. M. Ali, M. R. McEwen, D. W. O. Rogers

    Purpose: There are three goals for this study: (a) to perform detailed megavoltage transmission measurements in order to identify the factors that affect the measurement accuracy, (b) to use the measured data as a benchmark for the EGSnrc system in order to identify the computational limiting factors, and (c) to provide data for others to benchmark Monte Carlo codes. Methods: Transmission measurements are performed at the National Research Council Canada on a research linac whose incident electron parameters are independently known. Automated transmission measurements are made on-axis, down to a transmission value of \u223c1.7, for eight beams between 10 MV (the lowest stable MV beam on the linac) and 30 MV, using fully stopping Be, Al, and Pb bremsstrahlung targets and no fattening filters. To diversify energy differentiation, data are acquired for each beam using low-Z and high-Z attenuators (C and Pb) and Farmer chambers with low-Z and high-Z buildup caps. Experimental corrections are applied for beam drifts (2), polarity (2.5 typical maximum, 6 extreme), ion recombination (0.2), leakage (0.3), and room scatter (0.8)-the values in parentheses are the largest corrections applied. The experimental setup and the detectors are modeled using EGSnrc, with the newly added photonuclear attenuation included (up to a 5.6 effect). A detailed sensitivity analysis is carried out for the measured and calculated transmission data. Results: The developed experimental protocol allows for transmission measurements with 0.4 uncertainty on the smallest signals. Suggestions for accurate transmission measurements are provided. Measurements and EGSnrc calculations agree typically within 0.2 for the sensitivity of the transmission values to the detector details, to the bremsstrahlung target material, and to the incident electron energy. Direct comparison of the measured and calculated transmission data shows agreement better than 2 for C (3.4 for the 10 MV beam) and typically better than 1 for Pb. The differences can be explained by acceptable photon cross section changes of 0.4. Conclusions: Accurate transmission measurements require accounting for a number of influence quantities which, if ignored, can collectively introduce errors larger than 10. Accurate transmission calculations require the use of the most accurate data and physics options available in EGSnrc, particularly the more accurate bremsstrahlung angular sampling option and the newly added modeling of photonuclear attenuation. Comparison between measurements and calculations implies that EGSnrc is accurate within 0.2 for relative ion chamber response calculations. Photon cross section uncertainties are the ultimate limiting factor for the accuracy of the calculated transmission data (Monte Carlo or analytical). \ua9 2012 American Association of Physicists in Medicine.Peer reviewed: YesNRC publication: Ye


  • An improved physics-based approach for unfolding megavoltage bremsstrahlung spectra using transmission analysis

    by E. S. M. Ali, D. W. O. Rogers

    To develop a physics-based approach to improve the accuracy and robustness of the ill-conditioned problem of unfolding megavoltage bremsstrahlung spectra from transmission data. Spectra are specified using a rigorously-benchmarked functional form. Since ion chambers are the typical detector used in transmission measurements, the energy response of a Farmer chamber is calculated using the EGSnrc Monte Carlo code, and the effect of approximating the energy response on the accuracy of the unfolded spectra is studied. A proposal is introduced to enhance spectral sensitivity by combining transmission data measured with multiple detectors of different energy response and by combining data from multiple attenuating materials. Monte Carlo methods are developed to correct for nonideal exponential attenuation (e.g., scatter effects and secondary attenuation). The performance of the proposed methods is evaluated for a diverse set of validated clinical spectra (3.5-25 MV) using analytical transmission data with simulated experimental noise. The approximations commonly used in previous studies for the ion-chamber energy response lead to significant errors in the unfolded spectra. Of the configurations studied, the one with best spectral sensitivity is to measure four full transmission curves using separate low-Z and high-Z attenuators in conjunction with two detectors of different energy response (the authors propose a Farmer-type ion chamber, once with a low-Z, and once with a high-Z buildup cap material), then to feed the data simultaneously to the unfolding algorithm. Deviations from ideal exponential attenuation are as much as 1.5% for the smallest transmission signals, and the proposed methods properly correct for those deviations. The transmission data with enhanced spectral sensitivity, combined with the accurate and flexible spectral functional form, lead to robust unfolding without requiring a priori knowledge of the spectrum. Compared with the commonly-used methods, the accuracy is improved for the unfolded spectra and for the unfolded mean incident electron kinetic energy by at least factors of three and four, respectively. With simulated experimental noise and a lowest transmission of 1%, the unfolded energy fluence spectra agree with the original spectra with a normalized root-mean-square deviation, %Δ(ψ), of 2.3%. The unfolded mean incident electron kinetic energies agree, on average, with the original values within 1.4%. A lowest transmission of only 10% still allows unfolding with %Δ(ψ) of 3.3%. In the presence of realistic experimental noise, the proposed approach significantly improves the accuracy and robustness of the spectral unfolding problem for all therapy and MV imaging beams of clinical interest.


  • Functional forms for photon spectra of clinical linacs

    by E S M Ali, D W O Rogers

    Specifying photon spectra of clinical linacs using a functional form is useful for many applications, including virtual source modelling and spectral unfolding from dosimetric measurements such as transmission data or depth-dose curves. In this study, 11 functional forms from the literature are compiled and quantitatively compared. A new function is proposed which offers improvements over existing ones. The proposed function is simple, physics-based and has four free parameters, one of which is the mean incident electron kinetic energy. A comprehensive benchmark set of validated, high-precision Monte Carlo spectra is generated and used to evaluate the strengths and limitations of different functions. The benchmark set has 65 spectra (3.5-30 MV) from Varian, Elekta, Siemens, Tomotherapy, Cyberknife and research linacs. The set includes spectra on- and off-axis from linacs with and without a flattening filter, and in treatment and imaging modes. The proposed function gives the lowest spectral deviations among all functions. It reproduces the energy fluence values in each bin for the benchmark set with a normalized root-mean-square deviation of 1.7%. The mean incident electron kinetic energy, maximum photon energy, most-probable energy and average energy are reproduced, on average, within 1.4%, 4.3%, 3.9% and 0.6% of their true values, respectively. The proposed function is well behaved when used for spectral unfolding from dosimetric data. The contribution of the 511 keV annihilation peak and the energy spread of the incident electron beam can be added as additional free parameters.


  • Quantifying the effect of off‐focal radiation on the output of kilovoltage x‐ray systems

    by E. S. M. Ali, D. W. O. Rogers

    In a typical x‐ray tube, off‐focal radiation is mainly generated by the backscattered electrons that reenter the anode outside the focal spot. In this study, BEAMnrc (an EGSnrc user‐code) is modified to simulate off‐focal radiation. The modified BEAMnrc code is used to study the characteristics of electrons that backscatter from the anode, and to quantify their effect on the output of typical x‐ray systems. Results show that the first generation backscatter coefficient is for tungsten anodes at diagnostic energies, and for molybdenum anodes at mammography energies. Second and higher generations of backscatter have a relatively minor contribution. At the patient plane, our simulation results are in excellent agreement with experimental measurements in the literature for the spectral shape of both the primary and the off‐focal components, and also for the integral off‐focal‐to‐primary ratio. The spectrum of the off‐focal component at the patient plane is softer than the primary, which causes a slight softening in the overall spectrum. For typical x‐ray systems, the off‐focal component increases patient exposure (for a given number of incident primary electrons) by up to 11% and reduces the half‐value layer and the effective energy of the average spectrum by up to 7% and 3%, respectively. The larger effects are for grounded cathode tubes, smaller interelectrode distance, higher tube voltage, lighter filtration, and less collimation. Simulation time increases by when the off‐focal radiation is included, but the overall simulation time remains of the order of a few minutes. This study concludes that the off‐focal radiation can have a non‐negligible effect on the output parameters of x‐ray systems and that it should be included in x‐ray tube simulations for more realistic modeling of these systems.


  • Benchmarking EGSnrc in the kilovoltage energy range against experimental measurements of charged particle backscatter coefficients

    by E S M Ali, D W O Rogers

    This study benchmarks the EGSnrc Monte Carlo code in the energy range of interest to kilovoltage medical physics applications (5-140 keV) against experimental measurements of charged particle backscatter coefficients. The benchmark consists of experimental data from 20 different published experiments (1954-2007) covering 35 different elements (4<or=Z<or=92), electron and positron backscatter, normal and oblique incidence, and backscatter from thin films. EGSnrc simulation results show excellent agreement with the vast majority of the experimental data. Possible experimental and computational uncertainties explaining the few noted discrepancies are discussed. This study concludes that for the energy range of interest to kilovoltage medical physics application, EGSnrc produces backscatter results within approximately 4% of the average of the majority of published experimental data. A documented EGSnrc user-code customized for backscatter calculations is available from the authors at http://www.physics.carleton.ca/clrp/backscatter.


  • Efficiency improvements of x‐ray simulations in EGSnrc user‐codes using bremsstrahlung cross‐section enhancement (BCSE)

    by E. S. M. Ali, D. W. O. Rogers

    This paper presents the implementation of the bremsstrahlung cross‐section enhancement (BCSE) variance‐reduction technique into the EGSnrc/BEAMnrc system. BCSE makes the simulation of x‐ray production from bremsstrahlung targets more efficient; it does so by artificially making the rare event of bremsstrahlung emission more abundant, which increases the number of statistically‐independent photons that contribute to reducing the variance of the quantity of interest without increasing the CPU time appreciably. BCSE does not perturb the charged‐particle transport in EGSnrc and it is made compatible with all other variance‐reduction techniques already used in EGSnrc and BEAMnrc, including range rejection, uniform bremsstrahlung splitting, and directional bremsstrahlung splitting. When optimally combining BCSE with splitting to simulate typical situations of interest in medical physics research and in clinical practice, efficiencies can be up to five orders of magnitude larger than those obtained with analog simulations, and up to a full order of magnitude larger than those obtained with optimized splitting alone (which is the state‐of‐the‐art of the EGSnrc/BEAMnrc system before this study was carried out). This study recommends that BCSE be combined with the existing splitting techniques for all EGSnrc/BEAMnrc simulations that involve bremsstrahlung targets, both in the kilovoltage and megavoltage range. Optimum cross‐section enhancement factors for typical situations in diagnostic x‐ray imaging and in radiotherapy are recommended, along with an easy algorithm for simulation optimization.