LPLech Papiez

Lech Papiez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lech Papiez has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Fundamental properties of the delivery of volumetric modulated arc therapy (VMAT) to static patient anatomy

    by D. Rangaraj, S. Oddiraju, B. Sun, L. Santanam, D. Yang, S. Goddu, L. Papiez

    Purpose: The primary goal of this article is to formulate volumetric modulated arc therapy (VMAT) delivery problem and study interdependence between several parameters (beam dose rate, gantry angular speed, and MLC leaf speed) in the delivery of VMAT treatment plan. The secondary aim is to provide delivery solution and prove optimality (minimal beam on time) of the solution. An additional goal of this study is to investigate alternative delivery approaches to VMAT (like constant beam dose rate and constant gantry angular speed delivery).Method: The problem of the VMAT delivery is formulated as a control problem with machine constraints. The relationships between parameters of arc therapy delivery are derived under the constraint of treatment plan invariance and limitations on delivery parameters. The nonuniqueness of arc therapy delivery solutions is revealed from these relations. The most efficient delivery of arc therapy is then formulated as optimal control problem and solved by geometrical methods. A computer program is developed to find numerical solutions for deliveries of specific VMAT plan.Results: Explicit examples of VMAT plan deliveries are computed and illustrated with graphical representations of the variability of delivery parameters. Comparison of delivery parameters with that of Varian's delivery are shown and discussed. Alternative delivery strategies such as constant gantry angular speed delivery and constant beam dose rate delivery are formulated and solutions are provided. The treatment times for all the delivery solutions are provided.Conclusion: The investigations derive and prove time optimal VMAT deliveries. The relationships between delivery parameters are determined. The optimal alternative delivery strategies are discussed.


  • General strategy for the protection of organs at risk in IMRT therapy of a moving body

    by Ramin M. Abolfath, Lech Papiez

    We investigated protection strategies of organs at risk (OARs) in intensity modulated radiation therapy(IMRT). These strategies apply to delivery of IMRT to moving body anatomies that show relative displacement of OAR in close proximity to a tumor target. We formulated an efficient genetic algorithm which makes it possible to search for global minima in a complex landscape of multiple irradiation strategies delivering a given, predetermined intensity map to a target. The optimal strategy was investigated with respect to minimizing the dosedelivered to the OAR. The optimization procedure developed relies on variability of all parameters available for control of radiationdelivery in modern linear accelerators, including adaptation of leaf trajectories and simultaneous modification of beam dose rate during irradiation. We showed that the optimization algorithms lead to a significant reduction in the dosedelivered to OAR in cases where organs at risk move relative to a treatment target.


  • Optical Enhancement of DNA-Base Radio-Resistivity

    by Ramin M. Abolfath, Lech Papiez, Strahinja Stojadinovic, Timothy Solberg

  • Extend Distance Treatment for Stereotactic Body Radiation Therapy of Lung Cancer

    by Long Huang, Lech Papiez, Ramin M. Abolfath, Ewa Papiez, Robert Timmerman, Timothy D. Solberg

  • Optimal delivery of DMLC Arc Therapy

    by Lech Papiez, Dharanipathy Rangaraj

  • Variable beam dose rate and DMLC IMRT to moving body anatomy

    by Lech Papież, Ramin M. Abolfath

    Derivation of formulas relating leaf speeds and beam dose rates for delivering planned intensity profiles to static and moving targets in dynamic multileaf collimator (DMLC) intensity modulated radiation therapy (IMRT) is presented. The analysis of equations determining algorithms for DMLC IMRT delivery under a variable beam dose rate reveals a multitude of possible delivery strategies for a given intensity map and for any given target motion patterns. From among all equivalent delivery strategies for DMLC IMRT treatments specific subclasses of strategies can be selected to provide deliveries that are particularly suitable for clinical applications providing existing delivery devices are used. Special attention is devoted to the subclass of beam dose rate variable DMLC delivery strategies to moving body anatomy that generalize existing techniques of such deliveries in Varian DMLC irradiation methodology to static body anatomy. Few examples of deliveries from this subclass of DMLC IMRT irradiations are investigated to illustrate the principle and show practical benefits of proposed techniques.


  • DMLC IMRT delivery to targets moving in 2D in Beam's Eye View

    by Dharanipathy Rangaraj, Geethpriya Palaniswaamy, Lech Papiez

    The goal of this article is to present the algorithm for DMLC leaf control capable of delivering IMRT to tumors that experience motion in two dimensions in the beams eye view (BEV) plane. The generic, two-dimensional (2D) motion of the projection of the rigid target on BEV plane can be divided into two components. The first component describes the motion of the projection of the target along the x axis (parallel to the MLC leaf motions) and the other describes the motion of the target projection on the y axis (perpendicular to the leaf motion direction). First, time optimal leaf trajectories are calculated independently for each leaf pair of the MLC assembly to compensate the x-axis component of the 2D motion of the target on the BEV. These leaf trajectories are then synchronized following the mid time (MT) synchronization procedure. To compensate for the y-axis component of the motion of the target projection on the BEV plane, the procedure of "switching" leaf pair trajectories in the upward (or downward) direction is executed when the target's BEV projection moves upward (or downward) from its equilibrium position along the y axis. When the intensity function is a 2D histogram, the error between the intended and delivered intensity in 2D DMLC IMRT delivery will depend on the shape of the intensity map and on the MLC physical constraint (leaf width and maximum admissible leaf speed). The MT synchronization of leaf trajectories decreases the impact of above constraints on the error in 2D DMLC IMRT intensity map delivery. The proof is provided, that if hardware constraints in the 2D DMLC IMRT delivery strategy are removed, the errors between planned and delivered 2D intensity maps are entirely eliminated. Examples of 2D DMLC IMRT delivery to rigid targets moving along elliptical orbits on BEV planes are calculated and analyzed for 20 clinical fluence maps. The comparisons between the intensity delivered without motion correction, with motion correction along x axis only, and with motion correction for full 2D motion of the target are calculated and quantitatively evaluated. The fluence maps were normalized to 100 MU and the rms difference between the desired and delivered fluence was 12 MU for no motion compensation, 11.18 MU for 1D compensation, and 4.73 MU for 2D motion compensations. The advantage of correcting for full 2D motion of target projected on the BEV plane is demonstrated.


  • Stereotactic body radiation therapy for early-stage non-small-cell lung cancer

    by Simon S Lo, Achilles J Fakiris, Lech Papiez, Ramzi Abdulrahman, Ronald C McGarry, Mark A Henderson, Jeffrey A Forquer, David Hoopes, Robert D Timmerman

    Stereotactic body radiation therapy has emerged as a novel oncologic therapy and experience with the use of stereotactic body radiation therapy for the treatment of early-stage non-small-cell lung cancer has grown over the last 10 years. This article reviews the radiobiologic, physical/technical and clinical aspects of stereotactic body radiation therapy for early-stage non-small-cell lung cancer. The literature is also reviewed.


  • Hypofractionation in radiation therapy and its impact

    by Lech Papiez, Robert Timmerman

    A brief history of the underlying principles of the conventional fractionation in radiation therapy is discussed, followed by the formulation of the hypothesis for hypofractionated stereotactic body radiation therapy (SBRT). Subsequently, consequences of the hypothesis for SBRT dose shaping and dose delivery techniques are sketched. A brief review of the advantages of SBRT therapy in light of the existing experience is then provided. Finally, the need for new technological developments is advocated to make SBRT therapies more practical, safer, and clinically more effective. It is finally concluded that hypofractionated SBRT treatment will develop into a new paradigm that will shape the future of radiation therapy by providing the means to suppress the growth of most carcinogen‐induced carcinomas and by supporting the cure of the disease.