Masahiro Kaneko
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Masahiro Kaneko has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
Kenji Eguchi
Teikyo Univ. (Japan)
31 shared publicationsNoriyuki Moriyama
National Cancer Ctr. Hospital (Japan)
30 shared publications- Noboru Niki
Univ. of Tokushima (Japan)
29 shared publications Hironobu Ohmatsu
National Cancer Ctr. Hospital East (Japan)
25 shared publications- Ryutaro Kakinuma
National Cancer Ctr. Research Ctr. for Cancer Prevention and Screening (Japan)
23 shared publications - Yoshiki Kawata
Univ. of Tokushima (Japan)
20 shared publications
Latest Publications
- 29 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8674, 86740X
Teleradiology network system on cloud using the web medical image conference system with a new information security solution
We have developed the teleradiology network system with a new information security solution that provided with web medical image conference system. In the teleradiology network system, the security of information network is very important subjects. We are studying the secret sharing scheme and the tokenization as a method safely to store or to transmit the confidential medical information used with the teleradiology network system. Secret sharing scheme is a method of dividing the confidential medical information into two or more tallies. Our method has the function of automatic backup. With automatic backup technology, if there is a failure in a single tally, there is redundant data already copied to other tally. Confidential information is preserved at an individual Data Center connected through internet because individual medical information cannot be decoded by using one tally at all. Therefore, even if one of the Data Centers is struck and information is damaged due to the large area disaster, the confidential medical information can be decoded by using the tallies preserved at the data center to which it escapes damage. Moreover, by using tokenization, the history information of dividing the confidential medical information into two or more tallies is prevented from lying scattered by replacing the history information with another character string. As a result, information is available only to those who have rightful access it and the sender of a message and the message itself are verified at the receiving point. We propose a new information transmission method and a new information storage method with a new information security solution.
- 29 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8674, 86740X
Teleradiology network system on cloud using the web medical image conference system with a new information security solution
We have developed the teleradiology network system with a new information security solution that provided with web medical image conference system. In the teleradiology network system, the security of information network is very important subjects. We are studying the secret sharing scheme and the tokenization as a method safely to store or to transmit the confidential medical information used with the teleradiology network system. Secret sharing scheme is a method of dividing the confidential medical information into two or more tallies. Our method has the function of automatic backup. With automatic backup technology, if there is a failure in a single tally, there is redundant data already copied to other tally. Confidential information is preserved at an individual Data Center connected through internet because individual medical information cannot be decoded by using one tally at all. Therefore, even if one of the Data Centers is struck and information is damaged due to the large area disaster, the confidential medical information can be decoded by using the tallies preserved at the data center to which it escapes damage. Moreover, by using tokenization, the history information of dividing the confidential medical information into two or more tallies is prevented from lying scattered by replacing the history information with another character string. As a result, information is available only to those who have rightful access it and the sender of a message and the message itself are verified at the receiving point. We propose a new information transmission method and a new information storage method with a new information security solution.
- 3 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7967, 796711
Teleradiology network system and computer-aided diagnosis workstation using the web medical image conference system with a new information security solution
We have developed the teleradiology network system with a new information security solution that provided with web medical image conference system. In the teleradiology network system, the security of information network is very important subjects. We are studying the secret sharing scheme as a method safely to store or to transmit the confidential medical information used with the teleradiology network system. The confidential medical information is exposed to the risk of the damage and intercept. Secret sharing scheme is a method of dividing the confidential medical information into two or more tallies. Individual medical information cannot be decoded by using one tally at all. Our method has the function of RAID. With RAID technology, if there is a failure in a single tally, there is redundant data already copied to other tally. Confidential information is preserved at an individual Data Center connected through internet because individual medical information cannot be decoded by using one tally at all. Therefore, even if one of the Data Centers is struck and information is damaged, the confidential medical information can be decoded by using the tallies preserved at the data center to which it escapes damage. We can safely share the screen of workstation to which the medical image of Data Center is displayed from two or more web conference terminals at the same time. Moreover, Real time biometric face authentication system is connected with Data Center. Real time biometric face authentication system analyzes the feature of the face image of which it takes a picture in 20 seconds with the camera and defends the safety of the medical information. We propose a new information transmission method and a new information storage method with a new information security solution.
- 3 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7967, 796711
Teleradiology network system and computer-aided diagnosis workstation using the web medical image conference system with a new information security solution
We have developed the teleradiology network system with a new information security solution that provided with web medical image conference system. In the teleradiology network system, the security of information network is very important subjects. We are studying the secret sharing scheme as a method safely to store or to transmit the confidential medical information used with the teleradiology network system. The confidential medical information is exposed to the risk of the damage and intercept. Secret sharing scheme is a method of dividing the confidential medical information into two or more tallies. Individual medical information cannot be decoded by using one tally at all. Our method has the function of RAID. With RAID technology, if there is a failure in a single tally, there is redundant data already copied to other tally. Confidential information is preserved at an individual Data Center connected through internet because individual medical information cannot be decoded by using one tally at all. Therefore, even if one of the Data Centers is struck and information is damaged, the confidential medical information can be decoded by using the tallies preserved at the data center to which it escapes damage. We can safely share the screen of workstation to which the medical image of Data Center is displayed from two or more web conference terminals at the same time. Moreover, Real time biometric face authentication system is connected with Data Center. Real time biometric face authentication system analyzes the feature of the face image of which it takes a picture in 20 seconds with the camera and defends the safety of the medical information. We propose a new information transmission method and a new information storage method with a new information security solution.
- Open Access
- 23 August 2010
- Published by Oxford University Press (OUP) in Japanese Journal of Clinical Oncology
- Vol. 40 (9) , 838-845
Changes and Current State of Diagnosis of Lung Cancer After Development of the Flexible Bronchofiberscope
The flexible bronchofiberscope developed by Ikeda et al. has brought about revolutionary changes in the diagnosis and treatment of lung cancer. Advances in this device are continuing to emerge and lesions even smaller than those visible to the naked eye can now be visualized. In addition, the use of ultrasound now enables diagnosis of extramural bronchial lesions. Bronchoscopy is also used for the treatment of early hilar lung cancer, and in patients with airway stenosis due to advanced cancer, laser therapy, brachytherapy, and stenting can be performed. The bronchofiberscope is also very useful for tissue sampling from the lung periphery. Further advances in computed tomography imaging have enabled bronchoscopy under computed tomography fluoroscopy, and virtual bronchoscopy images can be generated from computed tomography imaging. Navigation systems have been developed to show the target bronchus where instruments such as forceps should be guided. Computed tomography imaging has made remarkable advances, and computed tomography now plays a central role in chest imaging, including early detection of lesions by low-dose computed tomography, qualitative diagnosis by high-resolution computed tomography and diagnosis of disease progression by contrast computed tomography. Ikeda et al. introduced the concept of personal health data recording system to manage these various images but the technology was not mature enough at that time for implementation. With modern advances in information technology, this is likely to be realized using an electronic health record system.
- 23 August 2010
- Published by Oxford University Press (OUP) in Japanese Journal of Clinical Oncology
- Vol. 40 (9) , 838-845
Open AccessChanges and Current State of Diagnosis of Lung Cancer After Development of the Flexible Bronchofiberscope
The flexible bronchofiberscope developed by Ikeda et al. has brought about revolutionary changes in the diagnosis and treatment of lung cancer. Advances in this device are continuing to emerge and lesions even smaller than those visible to the naked eye can now be visualized. In addition, the use of ultrasound now enables diagnosis of extramural bronchial lesions. Bronchoscopy is also used for the treatment of early hilar lung cancer, and in patients with airway stenosis due to advanced cancer, laser therapy, brachytherapy, and stenting can be performed. The bronchofiberscope is also very useful for tissue sampling from the lung periphery. Further advances in computed tomography imaging have enabled bronchoscopy under computed tomography fluoroscopy, and virtual bronchoscopy images can be generated from computed tomography imaging. Navigation systems have been developed to show the target bronchus where instruments such as forceps should be guided. Computed tomography imaging has made remarkable advances, and computed tomography now plays a central role in chest imaging, including early detection of lesions by low-dose computed tomography, qualitative diagnosis by high-resolution computed tomography and diagnosis of disease progression by contrast computed tomography. Ikeda et al. introduced the concept of personal health data recording system to manage these various images but the technology was not mature enough at that time for implementation. With modern advances in information technology, this is likely to be realized using an electronic health record system.
- 26 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7260, 726034
Algorithm for lung cancer detection based on PET/CT images
The five year survival rate of the lung cancer is low with about twenty-five percent. In addition it is an obstinate lung cancer wherein three out of four people die within five years. Then, the early stage detection and treatment of the lung cancer are important. Recently, we can obtain CT and PET image at the same time because PET/CT device has been developed. PET/CT is possible for a highly accurate cancer diagnosis because it analyzes quantitative shape information from CT image and FDG distribution from PET image. However, neither benign-malignant classification nor staging intended for lung cancer have been established still enough by using PET/CT images. In this study, we detect lung nodules based on internal organs extracted from CT image, and we also develop algorithm which classifies benignmalignant and metastatic or non metastatic lung cancer using lung structure and FDG distribution(one and two hour after administering FDG). We apply the algorithm to 59 PET/CT images (malignant 43 cases [Ad:31, Sq:9, sm:3], benign 16 cases) and show the effectiveness of this algorithm.
- 26 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7260, 726034
Algorithm for lung cancer detection based on PET/CT images
The five year survival rate of the lung cancer is low with about twenty-five percent. In addition it is an obstinate lung cancer wherein three out of four people die within five years. Then, the early stage detection and treatment of the lung cancer are important. Recently, we can obtain CT and PET image at the same time because PET/CT device has been developed. PET/CT is possible for a highly accurate cancer diagnosis because it analyzes quantitative shape information from CT image and FDG distribution from PET image. However, neither benign-malignant classification nor staging intended for lung cancer have been established still enough by using PET/CT images. In this study, we detect lung nodules based on internal organs extracted from CT image, and we also develop algorithm which classifies benignmalignant and metastatic or non metastatic lung cancer using lung structure and FDG distribution(one and two hour after administering FDG). We apply the algorithm to 59 PET/CT images (malignant 43 cases [Ad:31, Sq:9, sm:3], benign 16 cases) and show the effectiveness of this algorithm.
- 6 March 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6915, 69152P
Classifying pulmonary nodules using dynamic enhanced CT images based on CT number histogram
Pulmonary nodule evaluation based on analyses of contrast-enhanced CT images becomes useful for differentiating malignant and benign nodules. There are several types of nodule regarding inside density (such as solid, mixed GGO, and pure GGO) and size. This paper presents relationships between contrast enhancement characteristics and nodule types. Thin-section, contrast-enhanced CT (pre-contrast, and post-contrast series acquired at 2 and 4 minutes) was performed on 86 patients with pulmonary nodules (42 benign and 44 malignant). Nodule regions were segmented from an isotropic volume reconstructed from each image series. In this study, the contrast-enhancement characteristics of nodules were quantified by using CT number histogram. The CT number histograms inside the segmented nodules were computed on pre-contrast and post-contrast series. A feature characterizing variation between two histograms was computed by subtracting the histogram of post-contrast series from that of pre-contrast series, and dividing the summation of subtracted frequency of each bin by the volume of the segmented nodule on pre-contrast series. The nodules were classified into five types (α, β, γ, δ, and ε) on the basis of internal features extracted from CT number histogram on pre-contrast series. The nodule data set was categorized into subset through the nodule type and size and the performance of the feature to classify malignant from benign nodules was evaluated for each subset.
- 6 March 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6915, 69152P
Classifying pulmonary nodules using dynamic enhanced CT images based on CT number histogram
Pulmonary nodule evaluation based on analyses of contrast-enhanced CT images becomes useful for differentiating malignant and benign nodules. There are several types of nodule regarding inside density (such as solid, mixed GGO, and pure GGO) and size. This paper presents relationships between contrast enhancement characteristics and nodule types. Thin-section, contrast-enhanced CT (pre-contrast, and post-contrast series acquired at 2 and 4 minutes) was performed on 86 patients with pulmonary nodules (42 benign and 44 malignant). Nodule regions were segmented from an isotropic volume reconstructed from each image series. In this study, the contrast-enhancement characteristics of nodules were quantified by using CT number histogram. The CT number histograms inside the segmented nodules were computed on pre-contrast and post-contrast series. A feature characterizing variation between two histograms was computed by subtracting the histogram of post-contrast series from that of pre-contrast series, and dividing the summation of subtracted frequency of each bin by the volume of the segmented nodule on pre-contrast series. The nodules were classified into five types (α, β, γ, δ, and ε) on the basis of internal features extracted from CT number histogram on pre-contrast series. The nodule data set was categorized into subset through the nodule type and size and the performance of the feature to classify malignant from benign nodules was evaluated for each subset.
- 6 March 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6916, 691621
Comparative evaluation of physicians' pulmonary nodule detection with reduced slice thickness at CT screening
With thin and thick section Multi-slice CT images at lung cancer screening, we have statistically and quantitatively shown and evaluated the diagnostic capabilities of these slice thicknesses on physicians' pulmonary nodule diagnosis. To comparatively evaluate the 2 mm and 10 mm slice thicknesses, MSCT images of 360 people were read by six physicians. The reading criteria consisted of nodule for further examination (NFE), nodule for no further examination (NNFE) and no abnormality (NA) case. For reading results evaluation; firstly, cross-tabulation was carried out to roughly analyze the diagnoses based on whole lung field and each lung lobes. Secondly, from semi-automated extraction result of the nodule, detailed quantitative analysis was carried out to determine the diagnostic capabilities of two slice thicknesses. Finally, using the reading results of 2 mm thick image as the gold standard, the diagnostic capabilities were analyzed through the features and locations of pulmonary nodules. The study revealed that both slice thicknesses can depict lung cancer. Thin section may not be effective to diagnose nodules of ≤3 mm in size and nodules of ≤ 5mm in size for thick section. Though thick section is less tiring for reading physicians, it is not good at depicting nodules located at the border of lung upper lobe and which have a pixel size distance of ≤5 from the chest wall. The information presented may serve as a useful reference to determine in which particular pulmonary nodule condition the two slice thicknesses can be effectively used for early detection of lung cancer.
- 6 March 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6916, 691621
Comparative evaluation of physicians' pulmonary nodule detection with reduced slice thickness at CT screening
With thin and thick section Multi-slice CT images at lung cancer screening, we have statistically and quantitatively shown and evaluated the diagnostic capabilities of these slice thicknesses on physicians' pulmonary nodule diagnosis. To comparatively evaluate the 2 mm and 10 mm slice thicknesses, MSCT images of 360 people were read by six physicians. The reading criteria consisted of nodule for further examination (NFE), nodule for no further examination (NNFE) and no abnormality (NA) case. For reading results evaluation; firstly, cross-tabulation was carried out to roughly analyze the diagnoses based on whole lung field and each lung lobes. Secondly, from semi-automated extraction result of the nodule, detailed quantitative analysis was carried out to determine the diagnostic capabilities of two slice thicknesses. Finally, using the reading results of 2 mm thick image as the gold standard, the diagnostic capabilities were analyzed through the features and locations of pulmonary nodules. The study revealed that both slice thicknesses can depict lung cancer. Thin section may not be effective to diagnose nodules of ≤3 mm in size and nodules of ≤ 5mm in size for thick section. Though thick section is less tiring for reading physicians, it is not good at depicting nodules located at the border of lung upper lobe and which have a pixel size distance of ≤5 from the chest wall. The information presented may serve as a useful reference to determine in which particular pulmonary nodule condition the two slice thicknesses can be effectively used for early detection of lung cancer.
- 8 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6516, 65161E
Computer-aided diagnosis workstation and network system for chest diagnosis based on multislice CT images
Multislice CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multislice CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. Moreover, we have provided diagnostic assistance methods to medical screening specialists by using a lung cancer screening algorithm built into mobile helical CT scanner for the lung cancer mass screening done in the region without the hospital. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system.
- 8 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6516, 65161E
Computer-aided diagnosis workstation and network system for chest diagnosis based on multislice CT images
Multislice CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multislice CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. Moreover, we have provided diagnostic assistance methods to medical screening specialists by using a lung cancer screening algorithm built into mobile helical CT scanner for the lung cancer mass screening done in the region without the hospital. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system.
- 29 April 2005
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5747, 987-995
CAD system for lung cancer screening using low dose thick-slice CT images
Our group developed the computer aided diagnosis (CAD) system for lung cancer in 1996, and has been used in clinical field since 1997. From this CAD system (conventional system), we discovered problem and we attempted to solve the problem by using our proposed algorithm. The proposed algorithm succeeded in the improvement of the following three problems of the conventional system. (1) Weak extraction algorithm of region of interest (ROI) with noise, (2) Poor knowledge of chest structure, and (3) diagnostic processing for nodule of limited size. In this paper, the algorithm that solves problem (2) and (3) is described. We evaluated the proposed algorithm, which was applied to the following four databases. (A) Lung cancer database, (B) detailed examination database, (C) a large-scale screening database by 10mm-thickness images reconstructed from single-slice CT scan, and (D) a large-scale screening database by 10mm-thickness images reconstructed from multi-slice CT scan. The proposed method obtained the following successful results: Lung cancer database 95.7% TP and detailed examination 94.8% TP. For the large-scale screening database, we evaluated each examination process from physicians’ reading to cancer decision. The extraction rate of proposed algorithm improved as the examinations proceed. Two false positive results were obtained. False positive 1 (6.8-9.2 shadows/case) needed for a detailed examination and the object of false positive 2 (2.6-4.0 shadows/case) was an abnormal shadow.
- 29 April 2005
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5747, 987-995
CAD system for lung cancer screening using low dose thick-slice CT images
Our group developed the computer aided diagnosis (CAD) system for lung cancer in 1996, and has been used in clinical field since 1997. From this CAD system (conventional system), we discovered problem and we attempted to solve the problem by using our proposed algorithm. The proposed algorithm succeeded in the improvement of the following three problems of the conventional system. (1) Weak extraction algorithm of region of interest (ROI) with noise, (2) Poor knowledge of chest structure, and (3) diagnostic processing for nodule of limited size. In this paper, the algorithm that solves problem (2) and (3) is described. We evaluated the proposed algorithm, which was applied to the following four databases. (A) Lung cancer database, (B) detailed examination database, (C) a large-scale screening database by 10mm-thickness images reconstructed from single-slice CT scan, and (D) a large-scale screening database by 10mm-thickness images reconstructed from multi-slice CT scan. The proposed method obtained the following successful results: Lung cancer database 95.7% TP and detailed examination 94.8% TP. For the large-scale screening database, we evaluated each examination process from physicians’ reading to cancer decision. The extraction rate of proposed algorithm improved as the examinations proceed. Two false positive results were obtained. False positive 1 (6.8-9.2 shadows/case) needed for a detailed examination and the object of false positive 2 (2.6-4.0 shadows/case) was an abnormal shadow.
- 29 April 2005
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5747, 775-783
Computer-aided diagnosis algorithm for lung cancer using retrospective CT images
This paper presents a method for detecting suspicious nodules based on successive low-dose helical CT images. The method uses both initial and follow-up images to improve nodule detection performance. The basic idea of the detection is to register nodule images measured at different time and to assess the changes in size, shape, and density of the nodule. Since there are several variations of nodule changes, such as stable, shrinking, expansion in size, disappearance, appearance, and separation, a coarse-to-fine registration technique was adopted to deal with large nodule deformation. Especially, the fine registration is performed by excluding nodule regions and using nodule surroundings to avoid effects of nodule deformations in alignment task. In a preliminary experiment, the method was applied to ten cases with successive scans. From visual inspection, the corresponding results between initial and follow-up images were acceptable in clinical use. More researches using a large data set will be required. Still, we believe that the method has the potential of detecting suspicious nodules for use in a computer-aide diagnosis system.
- 29 April 2005
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5747, 775-783
Computer-aided diagnosis algorithm for lung cancer using retrospective CT images
This paper presents a method for detecting suspicious nodules based on successive low-dose helical CT images. The method uses both initial and follow-up images to improve nodule detection performance. The basic idea of the detection is to register nodule images measured at different time and to assess the changes in size, shape, and density of the nodule. Since there are several variations of nodule changes, such as stable, shrinking, expansion in size, disappearance, appearance, and separation, a coarse-to-fine registration technique was adopted to deal with large nodule deformation. Especially, the fine registration is performed by excluding nodule regions and using nodule surroundings to avoid effects of nodule deformations in alignment task. In a preliminary experiment, the method was applied to ten cases with successive scans. From visual inspection, the corresponding results between initial and follow-up images were acceptable in clinical use. More researches using a large data set will be required. Still, we believe that the method has the potential of detecting suspicious nodules for use in a computer-aide diagnosis system.
- 15 April 2005
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5748, 480-491
Computer-aided diagnosis workstation for chest diagnosis based on multihelical CT images
Mass screening based on helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router. This electronic medical recording system and prototype internet system were developed so as not to loosen the communication among staffs of hospital. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system.
- 15 April 2005
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5748, 480-491
Computer-aided diagnosis workstation for chest diagnosis based on multihelical CT images
Mass screening based on helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router. This electronic medical recording system and prototype internet system were developed so as not to loosen the communication among staffs of hospital. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system.