Noboru Niki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Noboru Niki has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
Noriyuki Moriyama
National Cancer Ctr. Hospital (Japan)
37 shared publicationsKenji Eguchi
Teikyo Univ. (Japan)
36 shared publicationsHironobu Ohmatsu
National Cancer Ctr. Hospital East (Japan)
31 shared publications- Masahiro Kaneko
National Cancer Ctr. Hospital (Japan)
29 shared publications - Yoshiki Kawata
Univ. of Tokushima (Japan)
29 shared publications - Ryutaro Kakinuma
National Cancer Ctr. Research Ctr. for Cancer Prevention and Screening (Japan)
23 shared publications
Latest Publications
- 3 March 2017
- Published by SPIE-Intl Soc Optical Eng
- p. 101344C-101344C-7
A hybrid 3D region growing and 4D curvature analysis-based automatic abdominal blood vessel segmentation through contrast enhanced CT
- 3 March 2017
- Published by SPIE-Intl Soc Optical Eng
- p. 101344C-101344C-7
A hybrid 3D region growing and 4D curvature analysis-based automatic abdominal blood vessel segmentation through contrast enhanced CT
- 1 January 2015
- Vol. 35 (3) , 211-6
[3D Visualization for Computer-Aided Diagnosis in Thoracic CT].
Medical imaging is one of the major tools that have enriched medical science, disease detection and treatment. Computed tomography (CT) is the most widely used imaging modality in clinical practice for cancer detection, oncologic diagnosis, and treatment guidance. Recent advances in CT imaging technologies allow the high-throughput extraction of informative imaging features to quantify the differences that oncologic tissues exhibit. The development of computer-aided detection/diagnosis (CADe/CADx) systems based on imaging biomakers associated with disease probabilities may become increasingly an attractive field to support clinicians in detecting early-stage diseases and determining risk-adaptive treatments. Three-dimensional visualization for CADe/CADx systems may have a large impact as various imaging modalities are routinely used in clinical practice to improve medical decision-support. In this article, we present some examples of 3D visualization for CADe/CADx systems of thoracic CT images.
- 1 January 2015
- Vol. 35 (3) , 211-6
[3D Visualization for Computer-Aided Diagnosis in Thoracic CT].
Medical imaging is one of the major tools that have enriched medical science, disease detection and treatment. Computed tomography (CT) is the most widely used imaging modality in clinical practice for cancer detection, oncologic diagnosis, and treatment guidance. Recent advances in CT imaging technologies allow the high-throughput extraction of informative imaging features to quantify the differences that oncologic tissues exhibit. The development of computer-aided detection/diagnosis (CADe/CADx) systems based on imaging biomakers associated with disease probabilities may become increasingly an attractive field to support clinicians in detecting early-stage diseases and determining risk-adaptive treatments. Three-dimensional visualization for CADe/CADx systems may have a large impact as various imaging modalities are routinely used in clinical practice to improve medical decision-support. In this article, we present some examples of 3D visualization for CADe/CADx systems of thoracic CT images.
- 29 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8674, 86740X
Teleradiology network system on cloud using the web medical image conference system with a new information security solution
We have developed the teleradiology network system with a new information security solution that provided with web medical image conference system. In the teleradiology network system, the security of information network is very important subjects. We are studying the secret sharing scheme and the tokenization as a method safely to store or to transmit the confidential medical information used with the teleradiology network system. Secret sharing scheme is a method of dividing the confidential medical information into two or more tallies. Our method has the function of automatic backup. With automatic backup technology, if there is a failure in a single tally, there is redundant data already copied to other tally. Confidential information is preserved at an individual Data Center connected through internet because individual medical information cannot be decoded by using one tally at all. Therefore, even if one of the Data Centers is struck and information is damaged due to the large area disaster, the confidential medical information can be decoded by using the tallies preserved at the data center to which it escapes damage. Moreover, by using tokenization, the history information of dividing the confidential medical information into two or more tallies is prevented from lying scattered by replacing the history information with another character string. As a result, information is available only to those who have rightful access it and the sender of a message and the message itself are verified at the receiving point. We propose a new information transmission method and a new information storage method with a new information security solution.
- 29 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8674, 86740X
Teleradiology network system on cloud using the web medical image conference system with a new information security solution
We have developed the teleradiology network system with a new information security solution that provided with web medical image conference system. In the teleradiology network system, the security of information network is very important subjects. We are studying the secret sharing scheme and the tokenization as a method safely to store or to transmit the confidential medical information used with the teleradiology network system. Secret sharing scheme is a method of dividing the confidential medical information into two or more tallies. Our method has the function of automatic backup. With automatic backup technology, if there is a failure in a single tally, there is redundant data already copied to other tally. Confidential information is preserved at an individual Data Center connected through internet because individual medical information cannot be decoded by using one tally at all. Therefore, even if one of the Data Centers is struck and information is damaged due to the large area disaster, the confidential medical information can be decoded by using the tallies preserved at the data center to which it escapes damage. Moreover, by using tokenization, the history information of dividing the confidential medical information into two or more tallies is prevented from lying scattered by replacing the history information with another character string. As a result, information is available only to those who have rightful access it and the sender of a message and the message itself are verified at the receiving point. We propose a new information transmission method and a new information storage method with a new information security solution.
- 27 June 2012
- Published by Wiley in Medical Physics
- Vol. 39 (7Part1) , 4347-4364
A method for determining the modulation transfer function from thick microwire profiles measured with x-ray microcomputed tomography
This study describes a model-dependent method to determine the modulation transfer function (MTF) in the transversal plane, obtained by a microcomputed tomography (micro-CT) system from profiles of a thick wire phantom instead of a thin wire phantom, and the study evaluates the feasibility of the proposed method in the MTF determination of micro-CT systems. The MTF is generally calculated as the absolute value of the normalized Fourier transform from the point spread function obtained by scanning a thin wire phantom. Since the wire is not a point source, the raw MTF is corrected for the finite size of the wire phantom; a wire with too large a diameter introduces inaccuracies in the MTF values. Therefore, we solved the MTF determination from profiles of a thick wire phantom via MTF modeling on the basis of the symmetric Lévy function that generalizes Gaussian and Lorentzian functions. We then applied the method to profiles of wire phantoms (1 mm, 2 mm, and 3 mm in diameter) measured by a clinical CT system to evaluate the applicable diameter range of the thick wire phantom. Two types of reconstruction kernels (standard and sharp) were used in the clinical CT. The performance of the method was evaluated using microwire phantoms (10 and 30 μm in diameter) measured by a synchrotron radiation micro-CT (SRμCT) system, in which the Shepp-Logan filter and Ramachandran-Lakshminarayanan filter were used as the reconstruction kernel. The MTFs obtained using thin wire phantoms of 0.1 mm and 3 μm in diameter were regarded as the gold standard MTFs for the clinical CT and SRμCT, respectively. The root-mean-square error (RMSE) and relative error (RE) of the 10% value of the MTF were used to measure the difference between the MTF determined by the method and the gold standard. The mean RMSEs for two types of reconstruction kernels of three wire phantoms (1, 2, and 3 mm in diameter) were 0.0085, 0.012, and 0.021, respectively. The mean REs for the 1-, 2-, and 3-mm wire phantoms gave the same values of 2.0%, 3.5%, and 3.5%, respectively, for two types of reconstruction kernel. The MTFs determined from thick wire phantoms reveal the spatial resolution for the two kernels. The mean RMSEs for two types of reconstruction kernels of the microwire phantoms of 10 and 30 μm in diameter were 0.0045 and 0.0035, respectively. The mean REs of the two wire phantoms of 10 and 30 μm diameter had 4.0% and 3.1%, respectively, for two types of reconstruction kernel. Experimental data presented in this paper support the effectiveness of the model-dependent method based on the symmetric Lévy function. We conclude that the method is a useful approach for measuring the spatial resolution in the x∕y-scan plane (transversal orientation) of micro-CT systems by substituting a thick wire phantom for a thin wire phantom.
- 27 June 2012
- Published by Wiley in Medical Physics
- Vol. 39 (7Part1) , 4347-4364
A method for determining the modulation transfer function from thick microwire profiles measured with x-ray microcomputed tomography
This study describes a model-dependent method to determine the modulation transfer function (MTF) in the transversal plane, obtained by a microcomputed tomography (micro-CT) system from profiles of a thick wire phantom instead of a thin wire phantom, and the study evaluates the feasibility of the proposed method in the MTF determination of micro-CT systems. The MTF is generally calculated as the absolute value of the normalized Fourier transform from the point spread function obtained by scanning a thin wire phantom. Since the wire is not a point source, the raw MTF is corrected for the finite size of the wire phantom; a wire with too large a diameter introduces inaccuracies in the MTF values. Therefore, we solved the MTF determination from profiles of a thick wire phantom via MTF modeling on the basis of the symmetric Lévy function that generalizes Gaussian and Lorentzian functions. We then applied the method to profiles of wire phantoms (1 mm, 2 mm, and 3 mm in diameter) measured by a clinical CT system to evaluate the applicable diameter range of the thick wire phantom. Two types of reconstruction kernels (standard and sharp) were used in the clinical CT. The performance of the method was evaluated using microwire phantoms (10 and 30 μm in diameter) measured by a synchrotron radiation micro-CT (SRμCT) system, in which the Shepp-Logan filter and Ramachandran-Lakshminarayanan filter were used as the reconstruction kernel. The MTFs obtained using thin wire phantoms of 0.1 mm and 3 μm in diameter were regarded as the gold standard MTFs for the clinical CT and SRμCT, respectively. The root-mean-square error (RMSE) and relative error (RE) of the 10% value of the MTF were used to measure the difference between the MTF determined by the method and the gold standard. The mean RMSEs for two types of reconstruction kernels of three wire phantoms (1, 2, and 3 mm in diameter) were 0.0085, 0.012, and 0.021, respectively. The mean REs for the 1-, 2-, and 3-mm wire phantoms gave the same values of 2.0%, 3.5%, and 3.5%, respectively, for two types of reconstruction kernel. The MTFs determined from thick wire phantoms reveal the spatial resolution for the two kernels. The mean RMSEs for two types of reconstruction kernels of the microwire phantoms of 10 and 30 μm in diameter were 0.0045 and 0.0035, respectively. The mean REs of the two wire phantoms of 10 and 30 μm diameter had 4.0% and 3.1%, respectively, for two types of reconstruction kernel. Experimental data presented in this paper support the effectiveness of the model-dependent method based on the symmetric Lévy function. We conclude that the method is a useful approach for measuring the spatial resolution in the x∕y-scan plane (transversal orientation) of micro-CT systems by substituting a thick wire phantom for a thin wire phantom.
- 3 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7967, 796711
Teleradiology network system and computer-aided diagnosis workstation using the web medical image conference system with a new information security solution
We have developed the teleradiology network system with a new information security solution that provided with web medical image conference system. In the teleradiology network system, the security of information network is very important subjects. We are studying the secret sharing scheme as a method safely to store or to transmit the confidential medical information used with the teleradiology network system. The confidential medical information is exposed to the risk of the damage and intercept. Secret sharing scheme is a method of dividing the confidential medical information into two or more tallies. Individual medical information cannot be decoded by using one tally at all. Our method has the function of RAID. With RAID technology, if there is a failure in a single tally, there is redundant data already copied to other tally. Confidential information is preserved at an individual Data Center connected through internet because individual medical information cannot be decoded by using one tally at all. Therefore, even if one of the Data Centers is struck and information is damaged, the confidential medical information can be decoded by using the tallies preserved at the data center to which it escapes damage. We can safely share the screen of workstation to which the medical image of Data Center is displayed from two or more web conference terminals at the same time. Moreover, Real time biometric face authentication system is connected with Data Center. Real time biometric face authentication system analyzes the feature of the face image of which it takes a picture in 20 seconds with the camera and defends the safety of the medical information. We propose a new information transmission method and a new information storage method with a new information security solution.
- 3 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7967, 796711
Teleradiology network system and computer-aided diagnosis workstation using the web medical image conference system with a new information security solution
We have developed the teleradiology network system with a new information security solution that provided with web medical image conference system. In the teleradiology network system, the security of information network is very important subjects. We are studying the secret sharing scheme as a method safely to store or to transmit the confidential medical information used with the teleradiology network system. The confidential medical information is exposed to the risk of the damage and intercept. Secret sharing scheme is a method of dividing the confidential medical information into two or more tallies. Individual medical information cannot be decoded by using one tally at all. Our method has the function of RAID. With RAID technology, if there is a failure in a single tally, there is redundant data already copied to other tally. Confidential information is preserved at an individual Data Center connected through internet because individual medical information cannot be decoded by using one tally at all. Therefore, even if one of the Data Centers is struck and information is damaged, the confidential medical information can be decoded by using the tallies preserved at the data center to which it escapes damage. We can safely share the screen of workstation to which the medical image of Data Center is displayed from two or more web conference terminals at the same time. Moreover, Real time biometric face authentication system is connected with Data Center. Real time biometric face authentication system analyzes the feature of the face image of which it takes a picture in 20 seconds with the camera and defends the safety of the medical information. We propose a new information transmission method and a new information storage method with a new information security solution.
- 3 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7963, 79632B
Developments of thrombosis detection algorithm using the contrast enhanced CT images
In the diagnosis of thrombosis with no specific clinic symptoms, diagnostic imaging plays a greater role. Particularly, contrast Enhanced CT is low invasive diagnostics, and the thrombus in the pulmonary artery can be detected as a low density without the contrast effect. Moreover, because describing the change of concentration in lung field and the decline in lung blood vessel shadow is also possible, it is indispensable to diagnose of thrombosis. As the image diagnosis support, it is necessary to classify the pulmonary artery and vein that relate to the thrombosis, and to analyze the lung blood vessel quantitatively. The technique for detecting the thrombosis by detecting the position of the thrombus has been proposed so far. In this study, it aims to focusing on the dilation of the main pulmonary artery and to detect the thrombosis. The effectiveness of the method is shown by measuring the pulmonary trunk diameter by using the extracted pulmonary artery from contrast Enhanced CT through semi-automated method, and comparing it with a normal case.
- 3 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7963, 79632B
Developments of thrombosis detection algorithm using the contrast enhanced CT images
In the diagnosis of thrombosis with no specific clinic symptoms, diagnostic imaging plays a greater role. Particularly, contrast Enhanced CT is low invasive diagnostics, and the thrombus in the pulmonary artery can be detected as a low density without the contrast effect. Moreover, because describing the change of concentration in lung field and the decline in lung blood vessel shadow is also possible, it is indispensable to diagnose of thrombosis. As the image diagnosis support, it is necessary to classify the pulmonary artery and vein that relate to the thrombosis, and to analyze the lung blood vessel quantitatively. The technique for detecting the thrombosis by detecting the position of the thrombus has been proposed so far. In this study, it aims to focusing on the dilation of the main pulmonary artery and to detect the thrombosis. The effectiveness of the method is shown by measuring the pulmonary trunk diameter by using the extracted pulmonary artery from contrast Enhanced CT through semi-automated method, and comparing it with a normal case.
- 26 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7264, 726410
Computer-aided diagnosis workstation and telemedicine network system for chest diagnosis based on multislice CT images
Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. Moreover, the doctor who diagnoses a medical image is insufficient in Japan. To overcome these problems, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The functions to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and "Success in login" effective. As a result, patients' private information is protected. We can share the screen of Web medical image conference system from two or more web conference terminals at the same time. An opinion can be exchanged mutually by using a camera and a microphone that are connected with workstation. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.
- 26 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7264, 726410
Computer-aided diagnosis workstation and telemedicine network system for chest diagnosis based on multislice CT images
Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. Moreover, the doctor who diagnoses a medical image is insufficient in Japan. To overcome these problems, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The functions to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and "Success in login" effective. As a result, patients' private information is protected. We can share the screen of Web medical image conference system from two or more web conference terminals at the same time. An opinion can be exchanged mutually by using a camera and a microphone that are connected with workstation. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.
- 26 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7264, 726409
Development of lung cancer CT screening operating support system
In Japan, lung cancer death ranks first among men and third among women. Lung cancer death is increasing yearly, thus early detection and treatment are needed. For this reason, CT screening for lung cancer has been introduced. The CT screening services are roughly divided into three sections: office, radiology and diagnosis sections. These operations have been performed through paper-based or a combination of paper-based and an existing electronic health recording system. This paper describes an operating support system for lung cancer CT screening in order to make the screening services efficient. This operating support system is developed on the basis of 1) analysis of operating processes, 2) digitalization of operating information, and 3) visualization of operating information. The utilization of the system is evaluated through an actual application and users' survey questionnaire obtained from CT screening centers.
- 26 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7264, 726409
Development of lung cancer CT screening operating support system
In Japan, lung cancer death ranks first among men and third among women. Lung cancer death is increasing yearly, thus early detection and treatment are needed. For this reason, CT screening for lung cancer has been introduced. The CT screening services are roughly divided into three sections: office, radiology and diagnosis sections. These operations have been performed through paper-based or a combination of paper-based and an existing electronic health recording system. This paper describes an operating support system for lung cancer CT screening in order to make the screening services efficient. This operating support system is developed on the basis of 1) analysis of operating processes, 2) digitalization of operating information, and 3) visualization of operating information. The utilization of the system is evaluated through an actual application and users' survey questionnaire obtained from CT screening centers.
- 26 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7260, 726034
Algorithm for lung cancer detection based on PET/CT images
The five year survival rate of the lung cancer is low with about twenty-five percent. In addition it is an obstinate lung cancer wherein three out of four people die within five years. Then, the early stage detection and treatment of the lung cancer are important. Recently, we can obtain CT and PET image at the same time because PET/CT device has been developed. PET/CT is possible for a highly accurate cancer diagnosis because it analyzes quantitative shape information from CT image and FDG distribution from PET image. However, neither benign-malignant classification nor staging intended for lung cancer have been established still enough by using PET/CT images. In this study, we detect lung nodules based on internal organs extracted from CT image, and we also develop algorithm which classifies benignmalignant and metastatic or non metastatic lung cancer using lung structure and FDG distribution(one and two hour after administering FDG). We apply the algorithm to 59 PET/CT images (malignant 43 cases [Ad:31, Sq:9, sm:3], benign 16 cases) and show the effectiveness of this algorithm.
- 26 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7260, 726034
Algorithm for lung cancer detection based on PET/CT images
The five year survival rate of the lung cancer is low with about twenty-five percent. In addition it is an obstinate lung cancer wherein three out of four people die within five years. Then, the early stage detection and treatment of the lung cancer are important. Recently, we can obtain CT and PET image at the same time because PET/CT device has been developed. PET/CT is possible for a highly accurate cancer diagnosis because it analyzes quantitative shape information from CT image and FDG distribution from PET image. However, neither benign-malignant classification nor staging intended for lung cancer have been established still enough by using PET/CT images. In this study, we detect lung nodules based on internal organs extracted from CT image, and we also develop algorithm which classifies benignmalignant and metastatic or non metastatic lung cancer using lung structure and FDG distribution(one and two hour after administering FDG). We apply the algorithm to 59 PET/CT images (malignant 43 cases [Ad:31, Sq:9, sm:3], benign 16 cases) and show the effectiveness of this algorithm.
- 6 March 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6915, 69152P
Classifying pulmonary nodules using dynamic enhanced CT images based on CT number histogram
Pulmonary nodule evaluation based on analyses of contrast-enhanced CT images becomes useful for differentiating malignant and benign nodules. There are several types of nodule regarding inside density (such as solid, mixed GGO, and pure GGO) and size. This paper presents relationships between contrast enhancement characteristics and nodule types. Thin-section, contrast-enhanced CT (pre-contrast, and post-contrast series acquired at 2 and 4 minutes) was performed on 86 patients with pulmonary nodules (42 benign and 44 malignant). Nodule regions were segmented from an isotropic volume reconstructed from each image series. In this study, the contrast-enhancement characteristics of nodules were quantified by using CT number histogram. The CT number histograms inside the segmented nodules were computed on pre-contrast and post-contrast series. A feature characterizing variation between two histograms was computed by subtracting the histogram of post-contrast series from that of pre-contrast series, and dividing the summation of subtracted frequency of each bin by the volume of the segmented nodule on pre-contrast series. The nodules were classified into five types (α, β, γ, δ, and ε) on the basis of internal features extracted from CT number histogram on pre-contrast series. The nodule data set was categorized into subset through the nodule type and size and the performance of the feature to classify malignant from benign nodules was evaluated for each subset.
- 6 March 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6915, 69152P
Classifying pulmonary nodules using dynamic enhanced CT images based on CT number histogram
Pulmonary nodule evaluation based on analyses of contrast-enhanced CT images becomes useful for differentiating malignant and benign nodules. There are several types of nodule regarding inside density (such as solid, mixed GGO, and pure GGO) and size. This paper presents relationships between contrast enhancement characteristics and nodule types. Thin-section, contrast-enhanced CT (pre-contrast, and post-contrast series acquired at 2 and 4 minutes) was performed on 86 patients with pulmonary nodules (42 benign and 44 malignant). Nodule regions were segmented from an isotropic volume reconstructed from each image series. In this study, the contrast-enhancement characteristics of nodules were quantified by using CT number histogram. The CT number histograms inside the segmented nodules were computed on pre-contrast and post-contrast series. A feature characterizing variation between two histograms was computed by subtracting the histogram of post-contrast series from that of pre-contrast series, and dividing the summation of subtracted frequency of each bin by the volume of the segmented nodule on pre-contrast series. The nodules were classified into five types (α, β, γ, δ, and ε) on the basis of internal features extracted from CT number histogram on pre-contrast series. The nodule data set was categorized into subset through the nodule type and size and the performance of the feature to classify malignant from benign nodules was evaluated for each subset.