YKYoshiki Kawata

Yoshiki Kawata

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yoshiki Kawata has a total of 61 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A hybrid 3D region growing and 4D curvature analysis-based automatic abdominal blood vessel segmentation through contrast enhanced CT

    by Ahmed S. Maklad, Mikio Matsuhiro, Hidenobu Suzuki, Yoshiki Kawata, Noboru Niki, Mitsuo Shimada, Gen Iinuma

    • 1 January 2015
      • Vol. 35  (3) , 211-6

    [3D Visualization for Computer-Aided Diagnosis in Thoracic CT].

    by Yoshiki Kawata, Hidenobu Suzkxi, Noboru Niki

    Medical imaging is one of the major tools that have enriched medical science, disease detection and treatment. Computed tomography (CT) is the most widely used imaging modality in clinical practice for cancer detection, oncologic diagnosis, and treatment guidance. Recent advances in CT imaging technologies allow the high-throughput extraction of informative imaging features to quantify the differences that oncologic tissues exhibit. The development of computer-aided detection/diagnosis (CADe/CADx) systems based on imaging biomakers associated with disease probabilities may become increasingly an attractive field to support clinicians in detecting early-stage diseases and determining risk-adaptive treatments. Three-dimensional visualization for CADe/CADx systems may have a large impact as various imaging modalities are routinely used in clinical practice to improve medical decision-support. In this article, we present some examples of 3D visualization for CADe/CADx systems of thoracic CT images.

  • A method for determining the modulation transfer function from thick microwire profiles measured with x-ray microcomputed tomography

    by Yoshihiro Nakaya, Yoshiki Kawata, Noboru Niki, Keiji Umetatni, Hironobu Ohmatsu, Noriyuki Moriyama

    This study describes a model-dependent method to determine the modulation transfer function (MTF) in the transversal plane, obtained by a microcomputed tomography (micro-CT) system from profiles of a thick wire phantom instead of a thin wire phantom, and the study evaluates the feasibility of the proposed method in the MTF determination of micro-CT systems. The MTF is generally calculated as the absolute value of the normalized Fourier transform from the point spread function obtained by scanning a thin wire phantom. Since the wire is not a point source, the raw MTF is corrected for the finite size of the wire phantom; a wire with too large a diameter introduces inaccuracies in the MTF values. Therefore, we solved the MTF determination from profiles of a thick wire phantom via MTF modeling on the basis of the symmetric Lévy function that generalizes Gaussian and Lorentzian functions. We then applied the method to profiles of wire phantoms (1 mm, 2 mm, and 3 mm in diameter) measured by a clinical CT system to evaluate the applicable diameter range of the thick wire phantom. Two types of reconstruction kernels (standard and sharp) were used in the clinical CT. The performance of the method was evaluated using microwire phantoms (10 and 30 μm in diameter) measured by a synchrotron radiation micro-CT (SRμCT) system, in which the Shepp-Logan filter and Ramachandran-Lakshminarayanan filter were used as the reconstruction kernel. The MTFs obtained using thin wire phantoms of 0.1 mm and 3 μm in diameter were regarded as the gold standard MTFs for the clinical CT and SRμCT, respectively. The root-mean-square error (RMSE) and relative error (RE) of the 10% value of the MTF were used to measure the difference between the MTF determined by the method and the gold standard. The mean RMSEs for two types of reconstruction kernels of three wire phantoms (1, 2, and 3 mm in diameter) were 0.0085, 0.012, and 0.021, respectively. The mean REs for the 1-, 2-, and 3-mm wire phantoms gave the same values of 2.0%, 3.5%, and 3.5%, respectively, for two types of reconstruction kernel. The MTFs determined from thick wire phantoms reveal the spatial resolution for the two kernels. The mean RMSEs for two types of reconstruction kernels of the microwire phantoms of 10 and 30 μm in diameter were 0.0045 and 0.0035, respectively. The mean REs of the two wire phantoms of 10 and 30 μm diameter had 4.0% and 3.1%, respectively, for two types of reconstruction kernel. Experimental data presented in this paper support the effectiveness of the model-dependent method based on the symmetric Lévy function. We conclude that the method is a useful approach for measuring the spatial resolution in the x∕y-scan plane (transversal orientation) of micro-CT systems by substituting a thick wire phantom for a thin wire phantom.


  • Developments of thrombosis detection algorithm using the contrast enhanced CT images

    by Jun Oya, Hidenobu Suzuki, Yoshiki Kawata, Noboru Niki, Toshihiko Sugiura, Nobuhiro Tanabe, Yuichi Takiguchi, Koichiro Tatsumi

    In the diagnosis of thrombosis with no specific clinic symptoms, diagnostic imaging plays a greater role. Particularly, contrast Enhanced CT is low invasive diagnostics, and the thrombus in the pulmonary artery can be detected as a low density without the contrast effect. Moreover, because describing the change of concentration in lung field and the decline in lung blood vessel shadow is also possible, it is indispensable to diagnose of thrombosis. As the image diagnosis support, it is necessary to classify the pulmonary artery and vein that relate to the thrombosis, and to analyze the lung blood vessel quantitatively. The technique for detecting the thrombosis by detecting the position of the thrombus has been proposed so far. In this study, it aims to focusing on the dilation of the main pulmonary artery and to detect the thrombosis. The effectiveness of the method is shown by measuring the pulmonary trunk diameter by using the extracted pulmonary artery from contrast Enhanced CT through semi-automated method, and comparing it with a normal case.

  • Development of lung cancer CT screening operating support system

    by Rikuta Ishigaki, Kozou Hanai, Masahiro Suzuki, Yoshiki Kawata, Noboru Niki, Kenji Eguchi, Ryutaro Kakinuma, Noriyuki Moriyama

    In Japan, lung cancer death ranks first among men and third among women. Lung cancer death is increasing yearly, thus early detection and treatment are needed. For this reason, CT screening for lung cancer has been introduced. The CT screening services are roughly divided into three sections: office, radiology and diagnosis sections. These operations have been performed through paper-based or a combination of paper-based and an existing electronic health recording system. This paper describes an operating support system for lung cancer CT screening in order to make the screening services efficient. This operating support system is developed on the basis of 1) analysis of operating processes, 2) digitalization of operating information, and 3) visualization of operating information. The utilization of the system is evaluated through an actual application and users' survey questionnaire obtained from CT screening centers.

  • Algorithm for lung cancer detection based on PET/CT images

    by Shinsuke Saita, Keita Ishimatsu, Mitsuru Kubo, Yoshiki Kawata, Noboru Niki, Hideki Ohtsuka, Hiromu Nishitani, Hironobu Ohmatsu, Kenji Eguchi, Masahiro Kaneko, et al.

    The five year survival rate of the lung cancer is low with about twenty-five percent. In addition it is an obstinate lung cancer wherein three out of four people die within five years. Then, the early stage detection and treatment of the lung cancer are important. Recently, we can obtain CT and PET image at the same time because PET/CT device has been developed. PET/CT is possible for a highly accurate cancer diagnosis because it analyzes quantitative shape information from CT image and FDG distribution from PET image. However, neither benign-malignant classification nor staging intended for lung cancer have been established still enough by using PET/CT images. In this study, we detect lung nodules based on internal organs extracted from CT image, and we also develop algorithm which classifies benignmalignant and metastatic or non metastatic lung cancer using lung structure and FDG distribution(one and two hour after administering FDG). We apply the algorithm to 59 PET/CT images (malignant 43 cases [Ad:31, Sq:9, sm:3], benign 16 cases) and show the effectiveness of this algorithm.

  • Classifying pulmonary nodules using dynamic enhanced CT images based on CT number histogram

    by Kazuhiro Minami, Yoshiki Kawata, Noboru Niki, Hironobu Ohmatsu, Kiyoshi Mori, Kouzou Yamada, Kenji Eguchi, Masahiro Kaneko, Noriyuki Moriyama

    Pulmonary nodule evaluation based on analyses of contrast-enhanced CT images becomes useful for differentiating malignant and benign nodules. There are several types of nodule regarding inside density (such as solid, mixed GGO, and pure GGO) and size. This paper presents relationships between contrast enhancement characteristics and nodule types. Thin-section, contrast-enhanced CT (pre-contrast, and post-contrast series acquired at 2 and 4 minutes) was performed on 86 patients with pulmonary nodules (42 benign and 44 malignant). Nodule regions were segmented from an isotropic volume reconstructed from each image series. In this study, the contrast-enhancement characteristics of nodules were quantified by using CT number histogram. The CT number histograms inside the segmented nodules were computed on pre-contrast and post-contrast series. A feature characterizing variation between two histograms was computed by subtracting the histogram of post-contrast series from that of pre-contrast series, and dividing the summation of subtracted frequency of each bin by the volume of the segmented nodule on pre-contrast series. The nodules were classified into five types (α, β, γ, δ, and ε) on the basis of internal features extracted from CT number histogram on pre-contrast series. The nodule data set was categorized into subset through the nodule type and size and the performance of the feature to classify malignant from benign nodules was evaluated for each subset.

  • Comparative evaluation of physicians' pulmonary nodule detection with reduced slice thickness at CT screening

    by Marodina Sinsuat, Ichiro Shimamura, Shinsuke Saita, Mitsuru Kubo, Yoshiki Kawata, Noboru Niki, Hironobu Ohmatsu, Ryutaro Kakinuma, Kenji Eguchi, Masahiro Kaneko, et al.

    With thin and thick section Multi-slice CT images at lung cancer screening, we have statistically and quantitatively shown and evaluated the diagnostic capabilities of these slice thicknesses on physicians' pulmonary nodule diagnosis. To comparatively evaluate the 2 mm and 10 mm slice thicknesses, MSCT images of 360 people were read by six physicians. The reading criteria consisted of nodule for further examination (NFE), nodule for no further examination (NNFE) and no abnormality (NA) case. For reading results evaluation; firstly, cross-tabulation was carried out to roughly analyze the diagnoses based on whole lung field and each lung lobes. Secondly, from semi-automated extraction result of the nodule, detailed quantitative analysis was carried out to determine the diagnostic capabilities of two slice thicknesses. Finally, using the reading results of 2 mm thick image as the gold standard, the diagnostic capabilities were analyzed through the features and locations of pulmonary nodules. The study revealed that both slice thicknesses can depict lung cancer. Thin section may not be effective to diagnose nodules of ≤3 mm in size and nodules of ≤ 5mm in size for thick section. Though thick section is less tiring for reading physicians, it is not good at depicting nodules located at the border of lung upper lobe and which have a pixel size distance of ≤5 from the chest wall. The information presented may serve as a useful reference to determine in which particular pulmonary nodule condition the two slice thicknesses can be effectively used for early detection of lung cancer.

  • Algorithm of pulmonary emphysema extraction using thoracic 3D CT images

    by Shinsuke Saita, Mitsuru Kubo, Yoshiki Kawata, Noboru Niki, Yasutaka Nakano, Hironobu Ohmatsu, Keigo Tominaga, Kenji Eguchi, Noriyuki Moriyama

    Recently, due to aging and smoking, emphysema patients are increasing. The restoration of alveolus which was destroyed by emphysema is not possible, thus early detection of emphysema is desired. We describe a quantitative algorithm for extracting emphysematous lesions and quantitatively evaluate their distribution patterns using low dose thoracic 3-D CT images. The algorithm identified lung anatomies, and extracted low attenuation area (LAA) as emphysematous lesion candidates. Applying the algorithm to thoracic 3-D CT images and then by follow-up 3-D CT images, we demonstrate its potential effectiveness to assist radiologists and physicians to quantitatively evaluate the emphysematous lesions distribution and their evolution in time interval changes.


  • Feature calculation for classification algorithm of pulmonary vein and artery

    by Takashi Nishio, Sinsuke Saita, Mitsuru Kubo, Yoshiki Kawata, Noboru Niki, Hironobu Ohmatsu, Ryuutarou Kakinuma, Noriyuki Moriyama, Kenji Eguchi

    Multi-slice helical CT technology has been developed. Unlike the conventional helical CT, we can obtain CT images of two or more slices in 1 time scan. Therefore, we can get many images with a clear contrast and thin slice images in one time of scanning. The purpose of this presentation is to evaluate the proposed automatic extraction bronchus and pulmonary vein and artery on multi-slice CT images. The bronchus is extracted by application with region growing technique and the morphological filters, 3D distance transformation. These results indicate that the proposed algorithm provides the ability to accurately develop an automatic extraction algorithm of the bronchus on multi-slice CT images. In this report, we used pulmonary vein and artery marked by the doctor, It aims to discover an amount of the feature necessary for classifying the pulmonary vein and artery by using the anatomical feature. The classification of the pulmonary vein and artery is thought to be a necessary information for tumor's benign or malignity judgment. In this report, the amount of the feature in which the flow of the automation is based is analyzed by using three dimension images of pulmonary vein and artery and bronchus obtained by the specialized physician's marking.