Noah D. Manring
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Noah D. Manring has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Roger Fales
Mechanical and Aerospace Engineering, University of Missouri-Columbia, Columbia, MO 65211
6 shared publications - Viral S. Mehta
Caterpillar, Inc., Peoria, IL 61656
4 shared publications - Jeff L. Kuehn
Caterpillar Inc., Peoria, IL 61656
3 shared publications - Bryan E. Nelson
Caterpillar Inc., Peoria, IL 61656
2 shared publications - Hasan H. Ali
Directorate of Reconstruction and Projects, Ministry of Higher Education and Scientific Research, Baghdad, Iraq
2 shared publications - Julie K. Wisch
Mechanical and Aerospace Engineering, University of Missouri-Columbia, Columbia, MO 65211
2 shared publications
Latest Publications
- 22 June 2020
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
Two Methods to Assess Aortic Compliance Using Blood Pressure and Pulse-Wave Velocity
Aortic compliance has been well established as an independent predictor of cardiovascular morbidity and mortality. The current "gold standard" for assessing aortic compliance is to use the carotid-femoral pulse-wave velocity (PWV) as a surrogate; however, PWV alone has been discussed in the literature as being inadequate for assessing compliance, especially for elderly patients and others who have a stiff aorta. In this paper an equation for the aortic compliance is developed using two approaches: 1) lumped-parameter modeling based on blood-pressure data and 2) distributed modeling based on the PWV. In-vitro experiments are conducted using a silicone-rubber tube which simulates the aorta, and an actual aorta harvested from a 1-year old, Holstein heifer. For both the rubber aorta and the Holstein aorta, a comparison is made between the blood-pressure model and the PWV model. In conclusion it is shown that good agreement exists between the two models, suggesting that either model may be used depending upon the available data. Furthermore, due to differences in material properties, it is shown that the compliance of the rubber aorta increases with mean arterial-pressure, while the compliance of the Holstein aorta decreases with mean arterial-pressure. Clinical implications of this research are also discussed.
- 22 June 2020
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
Two Methods to Assess Aortic Compliance Using Blood Pressure and Pulse-Wave Velocity
Aortic compliance has been well established as an independent predictor of cardiovascular morbidity and mortality. The current "gold standard" for assessing aortic compliance is to use the carotid-femoral pulse-wave velocity (PWV) as a surrogate; however, PWV alone has been discussed in the literature as being inadequate for assessing compliance, especially for elderly patients and others who have a stiff aorta. In this paper an equation for the aortic compliance is developed using two approaches: 1) lumped-parameter modeling based on blood-pressure data and 2) distributed modeling based on the PWV. In-vitro experiments are conducted using a silicone-rubber tube which simulates the aorta, and an actual aorta harvested from a 1-year old, Holstein heifer. For both the rubber aorta and the Holstein aorta, a comparison is made between the blood-pressure model and the PWV model. In conclusion it is shown that good agreement exists between the two models, suggesting that either model may be used depending upon the available data. Furthermore, due to differences in material properties, it is shown that the compliance of the rubber aorta increases with mean arterial-pressure, while the compliance of the Holstein aorta decreases with mean arterial-pressure. Clinical implications of this research are also discussed.
- 31 July 2019
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 141 (11)
Modeling and Control Design for an Inlet Metering Valve-Controlled Pump Used to Control Actuator Velocity Via H-Infinity and Two-Degrees-of-Freedom Methods
Using a unique inlet metering pump with fixed displacement and speed, this work introduces a new way to control a linear hydraulic actuator velocity. The inlet metering system consists of an inlet metering valve that adjusts the hydraulic fluid flow that enters the pump and a fixed displacement pump. Fluid is supplied to the inlet metering valve at a fixed pressure. Energy losses associated with flow metering in the system are reduced because the pressure drop across the inlet metering valve can be small compared to a traditional valve-controlled system. A velocity control system is designed using the inlet metering pump to control the fluid flow into a hydraulic cylinder. First, the valve dynamic model is ignored, the open-loop response is studied, and closed-loop proportional and proportional derivative controllers are designed. Next, the valve dynamic model is included and closed-loop proportional integral derivative, H∞, and two-degrees-of-freedom controllers are designed. Designs with the goals of stability and performance of the system are considered so that a precise velocity control system for the hydraulic cylinder is achieved. In addition to the potentially high efficiency of this system, there is potential for low-cost, fast-response, and less complicated dynamics compared to other systems. The results show that the velocity control system can be designed so that the system is stable for all cases and with 0% overshoot and no oscillation depending on valve dynamics using the two-degrees-of-freedom controller for tracking the desired velocity.
- 31 July 2019
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 141 (11)
Modeling and Control Design for an Inlet Metering Valve-Controlled Pump Used to Control Actuator Velocity Via H-Infinity and Two-Degrees-of-Freedom Methods
Using a unique inlet metering pump with fixed displacement and speed, this work introduces a new way to control a linear hydraulic actuator velocity. The inlet metering system consists of an inlet metering valve that adjusts the hydraulic fluid flow that enters the pump and a fixed displacement pump. Fluid is supplied to the inlet metering valve at a fixed pressure. Energy losses associated with flow metering in the system are reduced because the pressure drop across the inlet metering valve can be small compared to a traditional valve-controlled system. A velocity control system is designed using the inlet metering pump to control the fluid flow into a hydraulic cylinder. First, the valve dynamic model is ignored, the open-loop response is studied, and closed-loop proportional and proportional derivative controllers are designed. Next, the valve dynamic model is included and closed-loop proportional integral derivative, H∞, and two-degrees-of-freedom controllers are designed. Designs with the goals of stability and performance of the system are considered so that a precise velocity control system for the hydraulic cylinder is achieved. In addition to the potentially high efficiency of this system, there is potential for low-cost, fast-response, and less complicated dynamics compared to other systems. The results show that the velocity control system can be designed so that the system is stable for all cases and with 0% overshoot and no oscillation depending on valve dynamics using the two-degrees-of-freedom controller for tracking the desired velocity.
- 22 November 2018
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 141 (3)
The Theoretical Volumetric Displacement of a Check-Valve Type, Digital Displacement Pump
This paper has been written to develop closed-form equations for describing the theoretical displacement of a check-valve type, digital displacement pump. In theory, the digital displacement pump is used to alter the apparent volumetric displacement of the machine by short circuiting the flow path for reciprocating pistons within the machine that would ordinarily deliver a full volumetric flow rate to the discharge side of the pump. The short circuiting for the pistons is achieved by opening and closing a digital valve connected to each piston chamber at a desired time during the kinematic cycle for each reciprocating piston. Experience with these machines has shown that the expected volumetric displacement for the machine tends to decrease with pressure. This paper presents a theoretical explanation for the reduced volumetric displacement of the pump and quantifies the expected behavior based upon the digital valve command, the residual volume of fluid within a single piston chamber, and the fluid bulk modulus-of-elasticity. In summary, it shown that the apparent volumetric displacement of the machine may be reduced by as much as 10% for high-displacement commands and by as much as 30% for low-displacement commands.
- 22 November 2018
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 141 (3)
The Theoretical Volumetric Displacement of a Check-Valve Type, Digital Displacement Pump
This paper has been written to develop closed-form equations for describing the theoretical displacement of a check-valve type, digital displacement pump. In theory, the digital displacement pump is used to alter the apparent volumetric displacement of the machine by short circuiting the flow path for reciprocating pistons within the machine that would ordinarily deliver a full volumetric flow rate to the discharge side of the pump. The short circuiting for the pistons is achieved by opening and closing a digital valve connected to each piston chamber at a desired time during the kinematic cycle for each reciprocating piston. Experience with these machines has shown that the expected volumetric displacement for the machine tends to decrease with pressure. This paper presents a theoretical explanation for the reduced volumetric displacement of the pump and quantifies the expected behavior based upon the digital valve command, the residual volume of fluid within a single piston chamber, and the fluid bulk modulus-of-elasticity. In summary, it shown that the apparent volumetric displacement of the machine may be reduced by as much as 10% for high-displacement commands and by as much as 30% for low-displacement commands.
- 29 October 2018
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 141 (3)
Efficiency of a Fixed Displacement Pump With Flow Control Using an Inlet Metering Valve
Axial piston pumps with variable volumetric displacement are often used to control flow and pressure in hydraulic systems. The displacement control mechanism in these pumps occupies significant space and accounts for significant cost in the pump design. Fixed displacement pumps have lower cost and a more compact design but suffer from a significant energy consumption disadvantage due to the need to control flow and pressure by throttling flow and bypassing unused flow to pressures below the discharge pressure. An inlet metering valve-controlled pump marks a recent development in pumping technology for hydraulic systems. In this design, an inlet metering valve restricts inlet flow reducing inlet pressure so that the specific volume of the fluid is increased as it enters a fixed displacement pump. By altering the specific volume of the working fluid, the inlet metering valve permits precise control over the pump discharge flow. This paper presents a theoretical model for inlet metered pump efficiency. The work considers additional sources of energy loss unique to the inlet metering system. Experimental results associated with inlet metered pump efficiency are presented. A comparison of the theoretical model and the experimental results is also included. It is determined that the current efficiency model accurately predicts efficiencies determined using experimental data.
- 29 October 2018
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 141 (3)
Efficiency of a Fixed Displacement Pump With Flow Control Using an Inlet Metering Valve
Axial piston pumps with variable volumetric displacement are often used to control flow and pressure in hydraulic systems. The displacement control mechanism in these pumps occupies significant space and accounts for significant cost in the pump design. Fixed displacement pumps have lower cost and a more compact design but suffer from a significant energy consumption disadvantage due to the need to control flow and pressure by throttling flow and bypassing unused flow to pressures below the discharge pressure. An inlet metering valve-controlled pump marks a recent development in pumping technology for hydraulic systems. In this design, an inlet metering valve restricts inlet flow reducing inlet pressure so that the specific volume of the fluid is increased as it enters a fixed displacement pump. By altering the specific volume of the working fluid, the inlet metering valve permits precise control over the pump discharge flow. This paper presents a theoretical model for inlet metered pump efficiency. The work considers additional sources of energy loss unique to the inlet metering system. Experimental results associated with inlet metered pump efficiency are presented. A comparison of the theoretical model and the experimental results is also included. It is determined that the current efficiency model accurately predicts efficiencies determined using experimental data.
- 30 April 2018
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 140 (9)
Mapping the Efficiency of a Double Acting, Single-Rod Hydraulic-Actuator Using a Critically Centered Four-Way Spool Valve and a Load-Sensing Pump
In this paper, an efficiency map is created for a double-acting, single-rod hydraulic-actuator using a critically centered four-way spool valve and a load-sensing pump. The purpose of this research is to provide an understanding of the performance of a valve-controlled hydraulic actuator under all operating conditions. This paper considers a four-quadrant set of operating conditions, where each quadrant represents a different combination of actuator retraction or extension and overrunning or resistive loading. This four-quadrant efficiency map is the first presentation of its kind in the literature, and clearly demonstrates the performance characteristics and limitations for this hydraulic system. For its most common operation of an actuator extending under a resistive load, the map shows that this system can operate at over 82% efficiency and can move large loads. The map also shows physical limitations for the system, such as maximum pressure limits, maximum displacement limits, and valve limits. The efficiency map is plotted in nondimensional form, which presents the most general understanding of system performance and also allows dimensional values to be reconstructed for a similar system of any size.
- 30 April 2018
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 140 (9)
Mapping the Efficiency of a Double Acting, Single-Rod Hydraulic-Actuator Using a Critically Centered Four-Way Spool Valve and a Load-Sensing Pump
In this paper, an efficiency map is created for a double-acting, single-rod hydraulic-actuator using a critically centered four-way spool valve and a load-sensing pump. The purpose of this research is to provide an understanding of the performance of a valve-controlled hydraulic actuator under all operating conditions. This paper considers a four-quadrant set of operating conditions, where each quadrant represents a different combination of actuator retraction or extension and overrunning or resistive loading. This four-quadrant efficiency map is the first presentation of its kind in the literature, and clearly demonstrates the performance characteristics and limitations for this hydraulic system. For its most common operation of an actuator extending under a resistive load, the map shows that this system can operate at over 82% efficiency and can move large loads. The map also shows physical limitations for the system, such as maximum pressure limits, maximum displacement limits, and valve limits. The efficiency map is plotted in nondimensional form, which presents the most general understanding of system performance and also allows dimensional values to be reconstructed for a similar system of any size.
- 27 February 2018
- Published by Wiley in Journal of Mechanical Design
- Vol. 140 (4)
The Torque Capacity of a Magnetorheological Fluid Brake Compared to a Frictional Disk Brake
In this technical brief, the authors compare the torque capacity of a magnetorheological (MR) fluid brake with a conventional frictional disk brake. In the development of the torque models for both brakes, a mathematical expression for the compared torque ratio is presented. For the frictional disk brake, constant pressure and constant wear theories are considered, while static torque of the MR fluid brake is considered for comparison purpose only. Throughout the analysis, the outer radius of the compared brakes is assumed to be the same to ensure similarity of size, while the inner radius is selected to achieve maximum values of braking torque for both brake designs. Reasonable values of design variables for each brake are obtained from references and adopted in this study for making comparisons between the two designs. In conclusion, it is shown that the torque capacity for a frictional disk brake is 10–18 times greater than the torque capacity for a MR fluid brake of similar size.
- 27 February 2018
- Published by Wiley in Journal of Mechanical Design
- Vol. 140 (4)
The Torque Capacity of a Magnetorheological Fluid Brake Compared to a Frictional Disk Brake
In this technical brief, the authors compare the torque capacity of a magnetorheological (MR) fluid brake with a conventional frictional disk brake. In the development of the torque models for both brakes, a mathematical expression for the compared torque ratio is presented. For the frictional disk brake, constant pressure and constant wear theories are considered, while static torque of the MR fluid brake is considered for comparison purpose only. Throughout the analysis, the outer radius of the compared brakes is assumed to be the same to ensure similarity of size, while the inner radius is selected to achieve maximum values of braking torque for both brake designs. Reasonable values of design variables for each brake are obtained from references and adopted in this study for making comparisons between the two designs. In conclusion, it is shown that the torque capacity for a frictional disk brake is 10–18 times greater than the torque capacity for a MR fluid brake of similar size.
- 8 September 2017
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 140 (1)
Using Feedback Linearization to Improve the Tracking Performance of a Linear Hydraulic-Actuator
In this paper, a simple feedback linearization method is used to improve the tracking performance of a linear hydraulic-actuator. This research uses an open-centered four-way valve to control the displacement of the hydraulic actuator, based upon an input command from the operator. In this research, the operator is modeled as a first-order system with a bandwidth frequency of 2 Hz. The feedback linearization method is used to adjust the operator input based on the measurement of fluid pressure on only one side of the actuator and the pump pressure that supplies the valve. No other sensing is needed. Using this approach, the R-squared value for tracking a sinusoidal displacement of the actuator and the bandwidth frequency of the actuator are increased. Furthermore, it is shown that the feedback linearization method reduces and nearly eliminates the load dependence of the tracking response, which means that operators should have less difficulty learning how to operate the machine over a wide range of conditions, and the overall productivity of the machine should go up. In summary, the elegance of this model is found in the fact that it is very simple to implement and that the alterations in output performance are greatly enhanced.
- 8 September 2017
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 140 (1)
Using Feedback Linearization to Improve the Tracking Performance of a Linear Hydraulic-Actuator
In this paper, a simple feedback linearization method is used to improve the tracking performance of a linear hydraulic-actuator. This research uses an open-centered four-way valve to control the displacement of the hydraulic actuator, based upon an input command from the operator. In this research, the operator is modeled as a first-order system with a bandwidth frequency of 2 Hz. The feedback linearization method is used to adjust the operator input based on the measurement of fluid pressure on only one side of the actuator and the pump pressure that supplies the valve. No other sensing is needed. Using this approach, the R-squared value for tracking a sinusoidal displacement of the actuator and the bandwidth frequency of the actuator are increased. Furthermore, it is shown that the feedback linearization method reduces and nearly eliminates the load dependence of the tracking response, which means that operators should have less difficulty learning how to operate the machine over a wide range of conditions, and the overall productivity of the machine should go up. In summary, the elegance of this model is found in the fact that it is very simple to implement and that the alterations in output performance are greatly enhanced.
- 4 July 2017
- Published by Taylor & Francis
- p. 1-6
Introduction
- 4 July 2017
- Published by Taylor & Francis
- p. 7-16
Model Construction of Electro-Hydraulic Control System
- 4 July 2017
- Published by Taylor & Francis
- p. 7-16
Model Construction of Electro-Hydraulic Control System
- 22 March 2017
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 139 (6) , 064502
Dynamic Characteristics of a Pressure-Compensated Inlet-Metered Pump
Pressure-compensated pumps are routinely used for supplying fluid power for hydraulic control systems. These pumps traditionally exhibit significant overshoot and oscillation before reaching a steady-state pressure condition, thus requiring the use of downstream safety valves to prevent over pressurization. In addition to over pressurizing the hydraulic control system, the response of the traditional pressure-compensated pump often induces excessive noise and creates instability for other components within the system. In this paper, a nontraditional pressure-compensated hydraulic pump is studied based upon the paradigm that has been offered by diesel-engine technology. This technology uses an inlet-metered pump to provide pressurized fuel for the high-pressure, fuel-injector rail. The analysis of this paper shows that a system of this type may be used to produce a first-order pressure response with no overshoot and oscillation, and that the characteristic time constant and settling time may be designed by specifying parameters that are identified in this research. The problem of cavitation damage is also discussed based upon preliminary testing done at the University of Missouri, and it is suggested that by using hardened machine parts cavitation damage may be prevented in these machines. In conclusion, this paper shows that continued development of the inlet-metered pump may be warranted for those applications where pressure overshoot and oscillation cannot be tolerated due to safety, noise, or other dynamical considerations.
- 22 March 2017
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 139 (6) , 064502
Dynamic Characteristics of a Pressure-Compensated Inlet-Metered Pump
Pressure-compensated pumps are routinely used for supplying fluid power for hydraulic control systems. These pumps traditionally exhibit significant overshoot and oscillation before reaching a steady-state pressure condition, thus requiring the use of downstream safety valves to prevent over pressurization. In addition to over pressurizing the hydraulic control system, the response of the traditional pressure-compensated pump often induces excessive noise and creates instability for other components within the system. In this paper, a nontraditional pressure-compensated hydraulic pump is studied based upon the paradigm that has been offered by diesel-engine technology. This technology uses an inlet-metered pump to provide pressurized fuel for the high-pressure, fuel-injector rail. The analysis of this paper shows that a system of this type may be used to produce a first-order pressure response with no overshoot and oscillation, and that the characteristic time constant and settling time may be designed by specifying parameters that are identified in this research. The problem of cavitation damage is also discussed based upon preliminary testing done at the University of Missouri, and it is suggested that by using hardened machine parts cavitation damage may be prevented in these machines. In conclusion, this paper shows that continued development of the inlet-metered pump may be warranted for those applications where pressure overshoot and oscillation cannot be tolerated due to safety, noise, or other dynamical considerations.